In Vitro and In Vivo Studies of BMP-2-Loaded PCL-Gelatin-BCP Electrospun Scaffolds

被引:0
|
作者
Kim, Bo-Ram [1 ]
Thuy Ba Linh Nguyen [1 ,2 ]
Min, Young-Ki [2 ,3 ]
Lee, Byong-Taek [1 ,2 ]
机构
[1] Soonchunhyang Univ, Dept Regenerat Med, Coll Med, Cheonan 330090, South Korea
[2] Soonchunhyang Univ, Inst Tissue Regenerat, Coll Med, Cheonan 330090, South Korea
[3] Soonchunhyang Univ, Dept Physiol, Coll Med, Cheonan 330090, South Korea
关键词
BONE MORPHOGENETIC PROTEIN-2; CALCIUM-PHOSPHATE SCAFFOLD; DRUG-DELIVERY; STEM-CELLS; NANOFIBROUS SCAFFOLD; COMPOSITE SCAFFOLDS; CONTROLLED-RELEASE; GROWTH-FACTOR; TISSUE; FABRICATION;
D O I
10.1089/ten.tea.2014.0081
中图分类号
Q813 [细胞工程];
学科分类号
摘要
To confirm the effect of recombinant human bone morphogenetic protein-2 (BMP-2) for bone regeneration, BMP-2-loaded polycaprolactone (PCL)-gelatin (Gel)-biphasic calcium phosphate (BCP) fibrous scaffolds were fabricated using the electrospinning method. The electrospinning process to incorporate BCP nanoparticles into the PCL-Gel scaffolds yielded an extracellular matrix-like microstructure that was a hybrid system composed of nano- and micro-sized fibers. BMP-2 was homogeneously loaded on the PCL-Gel-BCP scaffolds for enhanced induction of bone growth. BMP-2 was initially released at high levels, and then showed sustained release behavior for 31 days. Compared with the PCL-Gel-BCP scaffold, the BMP-2-loaded PCL-Gel-BCP scaffold showed improved cell proliferation and cell adhesion behavior. Both scaffold types were implanted in rat skull defects for 4 and 8 weeks to evaluate the biological response under physiological conditions. Remarkable bone regeneration was observed in the BMP-2/PCL-Gel-BCP group. These results suggest that BMP-2-loaded PCL-Gel-BCP scaffolds should be considered for potential bone tissue engineering applications.
引用
收藏
页码:3279 / 3289
页数:11
相关论文
共 50 条
  • [21] Taurine-loaded poly (ε-caprolactone)/gelatin electrospun mat as a potential wound dressing material: In vitro and in vivo evaluation
    Farzamfar, Saeed
    Naseri-Nosar, Mahdi
    Samadian, Hadi
    Mahakizadeh, Simin
    Tajerian, Roksana
    Rahmati, Majid
    Vaez, Ahmad
    Salehi, Majid
    JOURNAL OF BIOACTIVE AND COMPATIBLE POLYMERS, 2018, 33 (03) : 282 - 294
  • [22] Controlling burst effect with PLA/PVA coaxial electrospun scaffolds loaded with BMP-2 for bone guided regeneration
    da Silva, Talita Nascimento
    Goncalves, Raquel Pires
    Rocha, Carol L.
    Archanjo, Braulio S.
    Barboza, Carlos Augusto G.
    Pierre, Maria Bernadete R.
    Reynaud, Franceline
    de Souza Picciani, Paulo Henrique
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 97 : 602 - 612
  • [23] EFFECT OF PORE DIRECTIONALITY OF BMP-2 AND BMP-2/VEGF-LOADED COLLAGEN SCAFFOLDS ON BONE FORMATION IN VIVO.
    Moncayo Donoso, Miguelangel
    Rico Llanos, Gustavo
    Garzon Alvarado, Diego Alexander
    Becerra Ratia, Jose
    Visser, Rick
    Fontanilla Duque, Marta
    TISSUE ENGINEERING PART A, 2022, 28 : S80 - S80
  • [24] Evaluation of BMP-2 and VEGF loaded 3D printed hydroxyapatite composite scaffolds with enhanced osteogenic capacity in vitro and in vivo
    Chen, Shangsi
    Shi, Yufei
    Zhang, Xin
    Ma, Jun
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 112
  • [25] Evaluation of Strontium-Containing PCL-PDIPF Scaffolds for Bone Tissue Engineering: In Vitro and In Vivo Studies
    Agustina Berenice Lino
    Antonio Desmond McCarthy
    Juan Manuel Fernández
    Annals of Biomedical Engineering, 2019, 47 : 902 - 912
  • [26] Evaluation of Strontium-Containing PCL-PDIPF Scaffolds for Bone Tissue Engineering: In Vitro and In Vivo Studies
    Berenice Lino, Agustina
    Desmond McCarthy, Antonio
    Manuel Fernandez, Juan
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (03) : 902 - 912
  • [27] In vitro evaluation of electrospun silk fibroin/nano-hydroxyapatite/BMP-2 scaffolds for bone regeneration
    Niu, Bingjie
    Li, Bin
    Gu, Yong
    Shen, Xiaofeng
    Liu, Yong
    Chen, Liang
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2017, 28 (03) : 257 - 270
  • [28] In vitro and in vivo evaluations of phenytoin sodium-loaded electrospun PVA, PCL, and their hybrid nanofibrous mats for use as active wound dressings
    Zahedi, Payam
    Rezaeian, Iraj
    Jafari, Seyed Hassan
    JOURNAL OF MATERIALS SCIENCE, 2013, 48 (08) : 3147 - 3159
  • [29] In vitro and in vivo evaluations of phenytoin sodium-loaded electrospun PVA, PCL, and their hybrid nanofibrous mats for use as active wound dressings
    Payam Zahedi
    Iraj Rezaeian
    Seyed Hassan Jafari
    Journal of Materials Science, 2013, 48 : 3147 - 3159
  • [30] In vitro and in vivo evaluation of linezolid loaded electrospun PLGA and PLGA/PCL fiber mats for prophylaxis and treatment of MRSA induced prosthetic infections
    Eren Boncu, Tugba
    Guclu, Aylin Uskudar
    Catma, Mehmet Faruk
    Savaser, Ayhan
    Gokce, Aysun
    Ozdemir, Nurten
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2020, 573