Potentiometric determination of the chloride ion activity in cement based materials

被引:76
作者
Angst, Ueli [1 ]
Elsener, Bernhard [2 ]
Larsen, Claus K. [1 ,3 ]
Vennesland, Oystein [1 ]
机构
[1] Norwegian Univ Sci & Technol, NTNU, Dept Struct Engn, N-7491 Trondheim, Norway
[2] ETH Honggerberg, Inst Bldg Mat IfB, ETH Zurich, CH-8093 Zurich, Switzerland
[3] Norwegian Publ Rd Adm, N-0033 Oslo, Norway
关键词
Ion selective electrode; Direct potentiometry; Membrane potential; Chloride induced corrosion; Reinforced concrete; HARDENED CEMENT; SELECTIVE ELECTRODES; PORE SOLUTIONS; CONCRETE; DIFFUSION; PASTES; POTENTIALS; SENSORS; ERROR; WATER;
D O I
10.1007/s10800-009-0029-6
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The chloride content at the reinforcement is one of the decisive factors for the initiation and propagation of localised corrosion in concrete structures. A monitoring technique for the chloride concentration which is accurate, non-destructive and continuous would thus be highly desirable. For this reason, the performance of ion selective electrodes (ISEs) was investigated both in alkaline solutions and embedded in mortar. The Ag/AgCl electrodes used in this work showed Nernstian behaviour with a slope of -59 +/- 1 mV per decade and a detection limit for chloride ions below 10(-2) mol dm(-3) even at pH close to 14; the selectivity coefficient for hydroxide interference was estimated at k(Cl)(-),(-Pot)(OH) approximate to 4.10(-3). The Ag/AgCl membranes show good long-term stability over more than 6 months even in highly alkaline solutions as long as chloride ions are present; in the complete absence of chloride the measured potentials were affected by the pH of the solution. The sensors are, however, able to recover fast as soon as they come into contact with chloride. When using ISEs embedded in concrete, diffusion potentials between the reference electrode and the ISE, as arising e. g. from gradients in pH, significantly affect the potential measurement and present a most important error source for the application of direct potentiometry to concrete. To minimise such errors, the reference electrode has to be positioned as close to the ISE as possible.
引用
收藏
页码:561 / 573
页数:13
相关论文
共 43 条
[1]  
American Society for Testing and Material, C1152 ASTM
[2]   Detecting critical chloride content in concrete using embedded ion selective electrodes - effect of liquid junction and membrane potentials [J].
Angst, U. ;
Vennesland, O. .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2009, 60 (08) :638-643
[3]  
ANGST U, 2009, 3 INT C CONCR REP CO, P401
[4]   Diffusion potentials as source of error in electrochemical measurements in concrete [J].
Angst, Ueli ;
Vennesland, Oystein ;
Myrdal, Roar .
MATERIALS AND STRUCTURES, 2009, 42 (03) :365-375
[5]  
[Anonymous], 1994, Corrosion
[6]  
[Anonymous], 2007, HDB CHEM PHYS, V88th
[7]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[8]  
[Anonymous], 2002, MAT STRUCT, V35, P583
[9]   Sources of error in using silver/silver chloride electrodes to monitor chloride activity in concrete [J].
Atkins, CP ;
Carter, MA ;
Scantlebury, JD .
CEMENT AND CONCRETE RESEARCH, 2001, 31 (08) :1207-1211
[10]   Monitoring chloride concentrations in hardened cement pastes using ion selective electrodes [J].
Atkins, CP ;
Scantlebury, JD ;
Nedwell, PJ ;
Blatch, SP .
CEMENT AND CONCRETE RESEARCH, 1996, 26 (02) :319-324