Ultrahigh-Resolution Measurement by Optical Coherence Tomography of Dynamic Tear Film Changes on Contact Lenses

被引:75
作者
Chen, Qi [2 ]
Wang, Jianhua [1 ]
Tao, Aizhu [2 ]
Shen, Meixiao [2 ]
Jiao, Shuliang
Lu, Fan [2 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Dept Ophthalmol, Miami, FL 33136 USA
[2] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
基金
美国国家卫生研究院;
关键词
IN-VIVO; HIGH-SPEED; DIURNAL-VARIATION; THICKNESS; PRECORNEAL; INTERFEROMETRY; STABILITY; MENISCI; PRELENS; IMPACT;
D O I
10.1167/iovs.09-4389
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the dynamic pre- and postlens tear film (PLTF and PoLTF) thicknesses by using optical coherence tomography (OCT). METHODS. Ultrahigh-resolution OCT was used to image the tear film of 22 subjects before and after contact lens wear. A soft lens with 1 drop of artificial tears on its concave surface was inserted onto one randomly selected eye. OCT images were taken before insertion, immediately afterward, and every 2 minutes for 10 minutes. For the contralateral eye, the lens inserted was not prewetted on the concave surface. OCT images were taken before insertion, immediately afterward, and at 3 minutes. Then another drop was instilled, and images were taken immediately afterward and every 2 minutes for 10 minutes. Images were processed by custom software to yield tear film thickness. RESULTS. The thickness of precorneal tear film (PCTF) was 1.9 +/- 0.9 mu m. The PoLTF was visualized clearly in all cases immediately after lens insertion, with 1 drop on the lens concave surface. Through the first 6 minutes after insertion, the PoLTF was greater than the PCTF. The PLTF (n = 12) and PoLTF (n = 9) were visualized immediately after lens insertion. After 3 minutes, the PLTF in most subjects and PoLTF in all subjects were invisible. The thickness of the PLTF increased after the instillation of artificial tears, whereas the PoLTF did not at any checkpoint for 10 minutes. CONCLUSIONS. Ultrahigh-resolution OCT is a promising tool for measuring the tear film. The PoLTF did not increase after instillation of artificial tears. (Invest Ophthalmol Vis Sci. 2010; 51: 1988-1993) DOI:10.1167/iovs.09-4389
引用
收藏
页码:1988 / 1993
页数:6
相关论文
共 32 条
[1]   Lens adherence and postlens tear film changes in closed-eye wear of hydrogel lenses [J].
Bruce, AS ;
Mainstone, JC .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) :28-34
[2]  
Bruce AS., 1988, INT CONTACT LENS CLI, V15, P304
[3]  
CAFFERY B, 1996, OPTOMETRY VISION SCI, V73, P109
[4]   In vivo corneal high-speed, ultra-high-resolution optical coherence tomography [J].
Christopoulos, Viki ;
Kagemann, Larry ;
Wollstein, Gadi ;
Ishikawa, Hi. Roshi ;
Gabriele, Michelle L. ;
Wojtkowski, Maciej ;
Srinivasan, Vivek ;
Fujimoto, James G. ;
Duker, Jay S. ;
Dhaliwal, Deepinder K. ;
Schuman, Joel S. .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (08) :1027-1035
[5]   In vivo tear-film thickness determination and implications for tear-film stability [J].
Creech, JL ;
Do, LT ;
Fatt, I ;
Radke, CJ .
CURRENT EYE RESEARCH, 1998, 17 (11) :1058-1066
[6]   AN INSTRUMENT FOR INVIVO TEAR FILM INTERFEROMETRY [J].
DOANE, MG .
OPTOMETRY AND VISION SCIENCE, 1989, 66 (06) :383-388
[7]   A patient questionnaire approach to estimating the prevalence of dry eye symptoms in patients presenting to optometric practices across Canada [J].
Doughty, MJ ;
Fonn, D ;
Richter, D ;
Simpson, T ;
Caffery, B ;
Gordon, K .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (08) :624-631
[8]   Interferometric measurement of tear film thickness by use of spectral oscillations [J].
Fogt, N ;
King-Smith, PE ;
Tuell, G .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (01) :268-275
[9]   Anterior chamber width measurement by high speed optical coherence tomography [J].
Goldsmith, JA ;
Li, Y ;
Chalita, MR ;
Westphal, V ;
Patil, CA ;
Rollins, AM ;
Izatt, JA ;
Huang, D .
OPHTHALMOLOGY, 2005, 112 (02) :238-244
[10]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589