Corneal surface reconstruction algorithm using Zernike polynomial representation: improvements

被引:11
|
作者
Turuwhenua, Jason [1 ]
机构
[1] Univ Auckland, Fac Engn, Bioengn Inst, Auckland 1, New Zealand
关键词
D O I
10.1364/JOSAA.24.001551
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently Sicam et at. [J. Opt. Soc. Am. A 21, 1300 (2004)] presented a new corneal reconstruction algorithm for estimating corneal sag by Zernike polynomials. An equivalent but simpler derivation of the model equations is presented. The algorithm is tested on a sphere, a conic, and a toric. These tests reveal significant height errors that accrue with distance from the corneal apex. Additional postprocessing steps are introduced to circumvent these errors. A consistent and significant reduction in height errors is observed across the test surfaces. Finally, Sicam et al. used the conic p-value p as a measure of algorithm efficacy. Further investigation shows that the finite Zernike representation affected the reported results. The p-value should therefore be used with caution as an efficacy measure. (c) 2007 Optical Society of America
引用
收藏
页码:1551 / 1561
页数:11
相关论文
共 50 条
  • [1] Corneal surface reconstruction algorithm that uses Zernike polynomial representation
    Sicam, VADP
    Coppens, J
    van den Berg, TJTP
    van der Heijde, RGL
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2004, 21 (07) : 1300 - 1306
  • [2] Corneal topography algorithm using pseudo random encoding and Zernike polynomial fitting
    Sicam, VDP
    Coppens, JE
    van den Berg, TJTP
    van der Heijde, GL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U5 - U5
  • [3] Surface reconstruction by using Zernike Polynomials
    Schilke, Manon
    Liebl, Johannes
    Wuensche, Christine
    THIRD EUROPEAN SEMINAR ON PRECISION OPTICS MANUFACTURING, 2016, 10009
  • [4] An Algorithm of Lens surface error compensation based on Zernike polynomial
    Chen Chunqi
    Shang Jianzhong
    Wu Wei
    ICOSM 2020: OPTOELECTRONIC SCIENCE AND MATERIALS, 2020, 11606
  • [5] Comparison of accuracy of zernike polynomials and Fourier series in corneal surface representation
    Alchagirov, A
    Klyce, D
    Smolek, MK
    Karon, MD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [6] Membrane Reflector Surface Reconstruction Using Zernike Polynomials and Two-stage Algorithm
    Chen, Zhenyu
    Liu, Yang
    Xu, Xiandong
    Li, Kang
    Chen, Xinglin
    IFAC PAPERSONLINE, 2015, 48 (28): : 632 - 637
  • [7] Goodness-of-prediction of Zernike polynomial fitting to corneal surfaces
    Smolek, MK
    Klyce, SD
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (12): : 2350 - 2355
  • [8] Reconstruction of turbulent optical wavefront realized by Zernike polynomial
    Zhang, Qiang
    Jiang, Wenhan
    Xu, Bing
    Guangdian Gongcheng/Opto-Electronic Engineering, 1998, 25 (06): : 15 - 19
  • [9] A Blind Deconvolution Algorithm using Zernike-polynomial-based Phase Fitting
    Ren, Zhilei
    Liu, Jin
    Liang, Yonghui
    ICAIP 2018: 2018 THE 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN IMAGE PROCESSING, 2018, : 54 - 58
  • [10] Wavefront analysis and Zernike polynomial decomposition for evaluation of corneal optical quality
    Oliveira, Cristina M.
    Ferreira, Andreia
    Franco, Sandra
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02): : 343 - 356