Minimizing the Acquisition Time for Intravoxel Incoherent Motion Magnetic Resonance Imaging Acquisitions in the Liver and Pancreas

被引:44
作者
Gurney-Champion, Oliver J. [1 ,2 ]
Froeling, Martijn [1 ,3 ]
Klaassen, Remy [4 ,5 ]
Runge, Jurgen H. [1 ]
Bel, Arjan [2 ]
van Laarhoven, Hanneke W. M.
Stoker, Jaap [1 ]
Nederveen, Aart J. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiol, Room Z0-178,Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiat Oncol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Med Oncol, NL-1105 AZ Amsterdam, Netherlands
[5] Univ Amsterdam, Acad Med Ctr, Lab Expt Oncol & Radiobiol, NL-1105 AZ Amsterdam, Netherlands
关键词
liver; postprocessing; diffusion-weighted imaging; pancreas; intravoxel incoherent motion; APPARENT-DIFFUSION-COEFFICIENT; B-VALUES; IN-VIVO; PARAMETERS; MRI; PERFUSION; LESIONS; DIFFERENTIATION; REPRODUCIBILITY; REPEATABILITY;
D O I
10.1097/RLI.0000000000000225
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study was to determine the combination of b-values and signal averages for diffusion-weighted image acquisitions that render the minimum acquisition time necessary to obtain values of the intravoxel incoherent motion (IVIM) model parameters in vivo in the pancreas or liver with acceptable reproducibility. Materials and Methods For 16 volunteers, diffusion-weighted images, with 14 b-values and 9 acquisitions per b-value, were acquired in 2 scan sessions. The IVIM model was fitted to data from lesion-sized regions of interest (ROIs) (1.7 cm(3)) as well as organ-sized ROIs in the pancreas and liver. By deleting data during analyzes, the IVIM model parameters, D and f, could be determined as a function of the number of b-values as well as the number of measurements per b-value taken along. For the IVIM model parameters, we examined the behavior reproducibility, in the form of the within-subject coefficient of variation (CVw), as a function of the amount of data taken along in the fits. Finally, we determined the minimum acquisition time required as a function of CVw. Result For the lesion-sized ROI, the intersession CV(w)s were 8%/46% and 13%/55% for D/f in the pancreas and liver, respectively, when all data were taken along. For 1.2 times larger CV(w)s, acquisition in the pancreas could be done in 5:15 minutes using 9 acquisitions per b-value at b = 0, 30, 50, 65, 100, 375, and 500 mm(-2)s and for the liver in 2:15 using 9 acquisitions per b-value at b = 0, 40, and 500 mm(-2)s. Conclusions Acquiring 7 b-values in the pancreas and 3 b-values in the liver only decreases the reproducibility by 20% compared with an acquisition with 14 b-values. The understanding of the behavior of reproducibility as a function of b-values and acquisitions per b-values scanned will help researchers select the shortest IVIM protocol.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 50 条
[41]   Assessment of Liver Perfusion by IntraVoxel Incoherent Motion (IVIM) Magnetic Resonance-Diffusion-Weighted Imaging: Correlation With Phase-Contrast Portal Venous Flow Measurements [J].
Regini, Francesco ;
Colagrande, Stefano ;
Mazzoni, Lorenzo Nicola ;
Busoni, Simone ;
Matteuzzi, Benedetta ;
Santini, Paolo ;
Wyttenbach, Rolf .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (03) :365-372
[42]   T1, T2 relaxation and magnetization transfer in tissue at 3T [J].
Stanisz, GJ ;
Odrobina, EE ;
Pun, J ;
Escaravage, M ;
Graham, SJ ;
Bronskill, MJ ;
Henkelman, RM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) :507-512
[43]   Diffusion-weighted MR Imaging of the Liver [J].
Taouli, Bachir ;
Koh, Dow-Mu .
RADIOLOGY, 2010, 254 (01) :47-66
[44]   Flow-compensated intravoxel incoherent motion diffusion imaging [J].
Wetscherek, Andreas ;
Stieltjes, Bram ;
Laun, Frederik Bernd .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) :410-419
[45]  
Wurnig MC, 2014, MAGN RESON MED, V00, P1
[46]   Statistical model for diffusion attenuated MR signal [J].
Yablonskiy, DA ;
Bretthorst, GL ;
Ackerman, JJH .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) :664-669
[47]   Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar MR imaging [J].
Yamada, I ;
Aung, W ;
Himeno, Y ;
Nakagawa, T ;
Shibuya, H .
RADIOLOGY, 1999, 210 (03) :617-623
[48]   Evaluation of Hepatic Focal Lesions Using Diffusion-Weighted MR Imaging: Comparison of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion-Derived Parameters [J].
Yoon, Jeong Hee ;
Lee, Jeong Min ;
Yu, Mi Hye ;
Kiefer, Berthold ;
Han, Joon Koo ;
Choi, Byung Ihn .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) :276-285
[49]   Variability of Renal Apparent Diffusion Coefficients: Limitations of the Monoexponential Model for Diffusion Quantification [J].
Zhang, Jeff L. ;
Sigmund, Eric E. ;
Chandarana, Hersh ;
Rusinek, Henry ;
Chen, Qun ;
Vivier, Pierre-Hugues ;
Taouli, Bachir ;
Lee, Vivian S. .
RADIOLOGY, 2010, 254 (03) :783-792
[50]  
Zhang S., 2015, CANC TRANSL MED, V1, P11