A numerical study into effects of intermittent pump operation on thermal storage in unsaturated porous media

被引:18
作者
Jahangir, Mohammad Hossein [1 ]
Ghazvini, Mahyar [1 ]
Pourfayaz, Fathollah [1 ]
Ahmadi, Mohammad Hossein [2 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
[2] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
关键词
Heat and moisture transfer; Ground heat pump; Numerical simulation; Unsaturated soil; Intermittent operation; BOREHOLE HEAT-EXCHANGER; COUPLED HEAT; MOISTURE TRANSFER; PERFORMANCE; SOIL; SYSTEM; TEMPERATURE; SIMULATION; MODEL; SUSTAINABILITY;
D O I
10.1016/j.applthermaleng.2018.04.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, the effects of varying soil properties and intermittent pump operation on the performance of the thermal storage system are examined using finite element numerical simulation. Furthermore, 10 days of intermittent operation, which involved different modes of pump operation like permanent on-and-off mode condition, 12-h active mode and 12-h off mode and unequal hours of pump operation are simulated in a single U-shaped pipe for both emitting and extracting modes and the cases have been selected for the various types of soil such as sand, silt, clay, and sandstone. According to the results, if the pump operates continuously, the heat increase is lower than which the pump switches off every 12 h, due to the initial condition of re-launching the system. Also, the process of increasing the saved heat in unsaturated clay for several modes of pump operation in emitting mode indicated that for every two-hour reduction of pump operation the media approximately faces 0.5 kJ/m(3) reduction of saved heat at the end of the tenth day. As the results indicate, the comparison of saved heat in four kinds of soil indicates that the highest saved heat is associated with sandstone and the lowest contributed to sand. So, the saved heat at the end of the tenth day for sandstone in the mode of 8-16 is approximately 15.5 kJ/m(3) and this value for sand is 10 kJ/m(3).
引用
收藏
页码:110 / 121
页数:12
相关论文
共 33 条
[1]   Transient heat transfer in a U-tube borehole heat exchanger [J].
Beier, Richard A. .
APPLIED THERMAL ENGINEERING, 2014, 62 (01) :256-266
[2]   Numerical investigation of a novel tube design for the geothermal borehole heat exchanger [J].
Bouhacina, Benamar ;
Saim, Rachid ;
Oztop, Hakan F. .
APPLIED THERMAL ENGINEERING, 2015, 79 :153-162
[3]   Numerical simulation of vertical ground heat exchangers: Intermittent operation in unsaturated soil conditions [J].
Choi, Jung Chan ;
Lee, Seung Rae ;
Lee, Dae Soo .
COMPUTERS AND GEOTECHNICS, 2011, 38 (08) :949-958
[4]   Performance of heat pumps with direct expansion in vertical ground heat exchangers in heating mode [J].
De Carli, Michele ;
Fiorenzato, Stefano ;
Zarrella, Angelo .
ENERGY CONVERSION AND MANAGEMENT, 2015, 95 :120-130
[5]   Heat, air and moisture transfer through hollow porous blocks [J].
dos Santos, Gerson Henrique ;
Mendes, Nathan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (9-10) :2390-2398
[6]   Analytical solution of discontinuous heat extraction for sustainability and recovery aspects of borehole heat exchangers [J].
Erol, Selcuk ;
Hashemi, Mir Amid ;
Francois, Bertrand .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 88 :47-58
[7]   Temperature distributions in boreholes of a vertical ground-coupled heat pump system [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Esen, Yuksel .
RENEWABLE ENERGY, 2009, 34 (12) :2672-2679
[8]   A study on the performance of a geothermal heat exchanger under coupled heat conduction and groundwater advection [J].
Fan, Rui ;
Jiang, Yiqiang ;
Yao, Yang ;
Shiming, Deng ;
Ma, Zuiliang .
ENERGY, 2007, 32 (11) :2199-2209
[9]   Numerical modeling of slinky-coil horizontal ground heat exchangers [J].
Fujii, Hikari ;
Nishi, Keita ;
Komaniwa, Yoshihito ;
Chou, Naokatsu .
GEOTHERMICS, 2012, 41 :55-62
[10]   A numerical study on the sustainability and efficiency of borehole heat exchanger coupled ground source heat pump systems [J].
Hein, Philipp ;
Kolditz, Olaf ;
Goerke, Uwe-Jens ;
Bucher, Anke ;
Shao, Haibing .
APPLIED THERMAL ENGINEERING, 2016, 100 :421-433