Transient performance of coupled heat and mass transfer in cross-flow hollow fiber membrane module for air dehumidification

被引:10
作者
Zhang, Ning [1 ]
Yin, Shao-You [2 ]
Yang, Hong-Hai [3 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Guangzhou 510640, Guangdong, Peoples R China
[2] Shunde Polytech, Heat Pump Engn & Technol Dev Ctr Guangdong Univ, Foshan 528333, Peoples R China
[3] Donghua Univ, Coll Environm Sci & Engn, Shanghai 201620, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2019年 / 108卷
关键词
Transient performance; Hollow fiber membrane contactor; Heat and mass transfer; Air dehumidification; COUNTER-CURRENT FLOW; PUMP DRIVEN; CONTACTOR; SYSTEM; MODEL;
D O I
10.1016/j.ijrefrig.2019.08.032
中图分类号
O414.1 [热力学];
学科分类号
摘要
Membrane-based liquid desiccant dehumidification has great advantages over traditional method, particularly in avoiding liquid droplets moving into the process air. This paper proposes a simple model to predict the transient performance of the hollow fiber membrane-based dehumidification module. To simplify the fiber-to-fiber influence, the modeled membrane module is assumed to be a parallel-plates heat mass exchanger. The model has been calibrated and validated with a transient experiment reasonably well. Impacts of various parameters on the transient performance were studied by using the proposed model. The results show that the variation of air temperature is more significant than air humidity. The absorption heat of water vapor is the main resistance of heat and mass transfer. It initially restricts the growth of the cooling effectiveness, and then limits the driving potential for moisture transfer. Therefore, it brings the dehumidification effectiveness down. It is found that reducing the heat capacity rate ratio can reduce the equilibrium time, and increase the cooling and dehumidification effectiveness. The high packing density increases the dehumidification effectiveness with a negligible effect of somewhat drop in cooling effectiveness. By contrast, the geometry of the fiber packing arrangement has little influence on dynamic performance of the module formed by numerous fibers. The membrane module can fit the change of weather conditions by varying solution temperature on the inlet of the dehumidifier with the help of this dynamic model. The cooling and dehumidification effectiveness also increase to improve heat and mass transfer performance of the dehumidifier under the adjustment. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:190 / 199
页数:10
相关论文
共 29 条
[1]  
Bergman T.L., 2007, Fundamentals of Heat and Mass Transfer
[2]   Experimental comparison and analysis on silica gel and polymer coated fin-tube heat exchangers [J].
Ge, T. S. ;
Dai, Y. J. ;
Wang, R. Z. ;
Peng, Z. Z. .
ENERGY, 2010, 35 (07) :2893-2900
[3]  
Guttman I., 1965, Introductory engineering statistics
[4]   Fundamental heat and mass transfer analysis in a quasi-counter flow parallel-plate three-fluid membrane contactor [J].
Huang, Si-Min ;
Zhang, Wen-Kai ;
Yang, Minlin ;
Liang, Cai-Hang ;
Cai, Zhuo-Di ;
Yuan, Wu-Zhi ;
Hong, Yuxiang ;
Ye, Wei-Biao .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 139 :186-194
[5]   Design optimizations of the thermal performance and cost in an air-gap hollow fiber membrane contactor (AHFMC) [J].
Huang, Si-Min ;
Huang, Wei-Hao ;
Yang, Minlin ;
Ye, Wei-Biao ;
Hong, Yuxiang ;
Yang, Xiaoxi .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 :1264-1273
[6]   Conjugate transport phenomena in a counter flow hollow fiber membrane tube bank: Effects of the fiber-to-fiber interactions [J].
Huang, Si-Min ;
Yang, Minlin ;
Zhong, Wen-Feng ;
Xu, Yongjun .
JOURNAL OF MEMBRANE SCIENCE, 2013, 442 :8-17
[7]  
Kays W. M., 1990, CONVECTIVE HEAT MASS
[8]   Dynamic modeling of a liquid desiccant dehumidifier [J].
Li, Xian ;
Liu, Shuai ;
Tan, Kok Kiong ;
Wang, Qing-Guo ;
Cai, Wen-Jian ;
Xie, Lihua .
APPLIED ENERGY, 2016, 180 :435-445
[9]   Investigation on the dynamic characteristics of the counter-current flow for liquid desiccant dehumidification [J].
Lu, Hao ;
Lu, Lin ;
Luo, Yimo ;
Qi, Ronghui .
ENERGY, 2016, 101 :229-238
[10]   Dynamic and microscopic simulation of the counter-current flow in a liquid desiccant dehumidifier [J].
Luo, Yimo ;
Yang, Hongxing ;
Lu, Lin .
APPLIED ENERGY, 2014, 136 :1018-1025