How skin anatomy influences transcutaneous bilirubin determinations: an in vitro evaluation

被引:14
作者
van Erk, Marlijn D. [1 ]
Dam-Vervloet, Alida J. [2 ]
de Boer, Foky-Anna [3 ]
Boomsma, Martijn F. [4 ]
van Straaten, Henrica [3 ]
Bosschaart, Nienke [1 ]
机构
[1] Univ Twente, Tech Med Ctr, Biomed Photon Imaging Grp, Enschede, Netherlands
[2] Isala Hosp, Med Phys Dept, Zwolle, Netherlands
[3] Isala Hosp, Neonatol Dept, Zwolle, Netherlands
[4] Isala Hosp, Tadiol Dept, Zwolle, Netherlands
关键词
TRANS-CUTANEOUS BILIRUBINOMETRY; OPTICAL-PROPERTIES; CEPHALOCAUDAL PROGRESSION; LIGHT-SCATTERING; SERUM BILIRUBIN; PRETERM INFANTS; JAUNDICE;
D O I
10.1038/s41390-019-0471-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BACKGROUND: Transcutaneous bilirubinometry is an effective screening method for neonatal hyperbilirubinemia. Current transcutaneous bilirubin (TcB) meters are designed for the "standard" situation of TcB determinations on the forehead or sternum of term newborns. We hypothesize that skin anatomy can considerably influence TcB determinations in non-standard situations- e.g., on preterm newborns or alternative body locations. METHODS: A commercially available TcB meter (JM-105) was evaluated in vitro on phantoms that accurately mimic neonatal skin. We varied the mimicked cutaneous hemoglobin content (0-2.5 g/L), bone depth (0.26-5.26 mm), and skin maturity-related light scattering (1.36-2.27 mm(-1)) within the clinical range and investigated their influence on the TcB determination. To obtain a reference frame for bone depth at the forehead, magnetic resonance head scans of 46 newborns were evaluated. RESULTS: The TcB meter adequately corrected for mimicked hemoglobin content. However, TcB determinations were influenced considerably by clinically realistic variations in mimicked bone depth and light scattering (deviations up to 72 mu mol/L). This greatly exceeds the specified accuracy of the device (+/- 25.5 mu mol/L). CONCLUSION: As bone depth and light scattering vary with gestational maturity and body location, caretakers should be cautious when interpreting TcB measurements on premature newborns and non-standard body locations.
引用
收藏
页码:471 / 477
页数:7
相关论文
共 15 条
  • [11] Skin bilirubin nomogram for the first 96 h of life in a European normal health newborn population, obtained with multiwavelength transcutaneous bilirubinometry
    De Luca, Daniele
    Romagnoli, Costantino
    Tiberi, Eloisa
    Zuppa, Antonio Alberto
    Zecca, Enrico
    ACTA PAEDIATRICA, 2008, 97 (02) : 146 - 150
  • [12] Accuracy of Transcutaneous Bilirubin Measurement from Unexposed Skin with a New Generation Device in Neonates Receiving Phototherapy
    Yoruk, Iren
    Oguz, Demet
    Elevli, Murat
    Ataoglu, Emel
    HASEKI TIP BULTENI-MEDICAL BULLETIN OF HASEKI, 2022, 60 (02): : 113 - 119
  • [13] Accuracy of transcutaneous bilirubin on covered skin in preterm and term newborns receiving phototherapy using a JM-105 bilirubinometer
    Costa-Posada, U.
    Concheiro-Guisan, A.
    Taboas-Ledo, M. F.
    Gonzalez-Colmenero, E.
    Gonzalez-Duran, M. L.
    Suarez-Albo, M.
    Duran Fernandez-Feijoo, C.
    Pumarada-Prieto, M.
    Martinez-Reglero, Cristina
    Fernandez-Lorenzo, J. R.
    JOURNAL OF PERINATOLOGY, 2020, 40 (02) : 226 - 231
  • [14] Usefulness of transcutaneous bilirubin assessment measured in non-photo-exposed skin to guide the length of phototherapy: an observational study
    Castro, Abdon
    Zozaya, Carlos
    Teresa Cuesta, Ma
    Gonzalez, Marina
    Villar, Gema
    Alcaraz, Andres
    JOURNAL OF PERINATAL MEDICINE, 2019, 47 (05) : 568 - 573
  • [15] A microscopic evaluation of collagen-bilirubin interactions: in vitro surface phenomenon
    Usharani, N.
    Jayakumar, G. C.
    Rao, J. R.
    Chandrasekaran, B.
    Nair, B. U.
    JOURNAL OF MICROSCOPY, 2014, 253 (02) : 109 - 118