Solution to the problem of interferences in electrochemical sensors using the fill-and-flow channel biosensor

被引:27
作者
Zhao, M [1 ]
Hibbert, DB [1 ]
Gooding, JJ [1 ]
机构
[1] Univ New S Wales, Sch Chem Sci, Sydney, NSW 2052, Australia
关键词
D O I
10.1021/ac026072l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A generic fill-and-flow channel biosensor with upstream electrodes to determine the extent of interferences in the sample is described. A pair of upstream electrodes poised at a suitable potential allows both the calculation of the extent of removal of interfering agents and the effect of interfering agents at the detector electrode. A model was developed and tested that predicts the concentrations of all species throughout the channel and, hence, the current at each electrode due to each species. This enables correction of the detector electrode current and a more accurate determination of the analyte concentration. The concept was applied to a biosensor for the determination of glucose in the presence of ascorbic acid, acetamidophenol, and uric acid, as well as glucose in wine samples containing polyphenolic interfering agents.
引用
收藏
页码:593 / 600
页数:8
相关论文
共 47 条
[1]  
[Anonymous], 1987, Biosensors Fundamentals and Applications
[2]   Layer-by-layer construction of enzyme multilayers on an electrode for the preparation of glucose and lactate sensors: Elimination of ascorbate interference by means of an ascorbate oxidase multilayer [J].
Anzai, J ;
Takeshita, H ;
Kobayashi, Y ;
Osa, T ;
Hoshi, T .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :811-817
[3]  
Bacon NC, 1999, ELECTROANAL, V11, P749, DOI 10.1002/(SICI)1521-4109(199907)11:10/11<749::AID-ELAN749>3.0.CO
[4]  
2-G
[5]   Voltammetric sensing of thiols. The electrocatalytic oxidation of 4-acetamidophenol in the presence of cysteine: a mechanistic rotating disk electrode study [J].
Brookes, BA ;
White, PC ;
Lawrence, NS ;
Compton, RG .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (27) :6361-6366
[6]   CHRONOAMPEROMETRY AT CHANNEL ELECTRODES - EXPERIMENTAL APPLICATIONS OF DOUBLE ELECTRODES [J].
COMPTON, RG ;
COLES, BA ;
GOODING, JJ ;
FISHER, AC ;
COX, TI .
JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (09) :2446-2451
[7]   CHRONOAMPEROMETRY AT CHANNEL ELECTRODES - THEORY OF DOUBLE ELECTRODES [J].
COMPTON, RG ;
COLES, BA ;
FISHER, AC .
JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (09) :2441-2445
[8]   MASS-TRANSPORT IN CHANNEL ELECTRODES - THE APPLICATION OF THE BACKWARDS IMPLICIT METHOD TO ELECTRODE-REACTIONS (EC, ECE AND DISP) INVOLVING COUPLED HOMOGENEOUS KINETICS [J].
COMPTON, RG ;
PILKINGTON, MBG ;
STEARN, GM .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1988, 84 :2155-2171
[9]   Electrochemical characterisation of uric acid and ascorbic acid at a platinum electrode [J].
Ernst, H ;
Knoll, M .
ANALYTICA CHIMICA ACTA, 2001, 449 (1-2) :129-134
[10]  
Gajovic N, 1999, ELECTROANAL, V11, P1377, DOI 10.1002/(SICI)1521-4109(199912)11:18<1377::AID-ELAN1377>3.0.CO