Flow injection analysis of nanomolar level orthophosphate in seawater with solid phase enrichment and colorimetric detection

被引:30
作者
Liang, Ying [1 ]
Yuan, Dongxing [1 ]
Li, Quanlong [1 ]
Lin, Qingmei [1 ]
机构
[1] Xiamen Univ, State Key Lab Marine Environm Sci, Environm Sci Res Ctr, Xiamen 361005, Peoples R China
基金
中国国家自然科学基金;
关键词
Sep-Pak C18; on-line solid phase extraction; orthophosphate; phosphomolybdenum blue; cetyltrimethylammonium bromide;
D O I
10.1016/j.marchem.2006.06.013
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Phosphomolybdenum blue (PMB) paired with cetyltrimethylammonium bromide (CTAB) can be extracted using a solid phase extraction technique on C18 sorbent. Based on this, a novel on-line solid phase extraction method coupled with flow injection (FI) analysis and colorimetric detection has been established to determine nanomolar level orthophosphate in seawater. A stopped flow technique was employed to assure the complete formation of the PMB-CTAB compound, which was sequentially extracted on an in-line Sep-Pak C-18 cartridge. The adsorbed PMB-CTAB can be rapidly eluted by 0.56 mol/L H2SO4 in ethanol, and determined with a spectrophotometer at 700 nm. Experimental parameters, including reaction temperature, sample loading flow rate, stopped time and eluting flow rate, were optimized throughout the experiments based on univariate experimental design. The results show that reaction temperature and stopped time were the major factors affecting the formation of PMB-CTAB. Silicate concentration up to 5000 times higher than that of orthophosphate would not interfere with the determination of orthophosphate. Using artificial seawater with salinity of 35 as a matrix under the optimized conditions, the standard curve shows a linear range between 3.2 and 48.5 nmol/L, and the recovery and the detection limit of the proposed method are 96.4% and 1.57 nmol/L, respectively. The relative standard deviation (RSD) (n=8), which was determined daily for 8 days, was 4.52% for the artificial seawater at a concentration of 32.4 nmol/L orthophosphate. Two typical seawater samples were analyzed using both the proposed method and the MAGnesiurn hydroxide-Induced Coprecipitation (MAGIC) method. The results of the two methods show no significant difference using the t test. Compared to the MAGIC method, the proposed method has the advantage of being more sensitive, faster, sample saving and easy for on-line analysis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 130
页数:9
相关论文
共 25 条
[1]  
ARNOLD GF, 1990, ANALYST, V115, P593
[2]  
Berger W., 1996, ENV LAB DATA EVALUAT, P2
[3]   A REVIEW OF SOLID-PHASE EXTRACTION - BASIC PRINCIPLES AND NEW DEVELOPMENTS [J].
BERRUETA, LA ;
GALLO, B ;
VICENTE, F .
CHROMATOGRAPHIA, 1995, 40 (7-8) :474-483
[4]  
BETTERIDGE D, 1978, ANALYST, V103, P897, DOI 10.1039/an9780300897
[5]   Nutrient gradients in the western North Atlantic Ocean: Relationship to microbial community structure and comparison to patterns in the Pacific Ocean [J].
Cavender-Bares, KK ;
Karl, DM ;
Chisholm, SW .
DEEP-SEA RESEARCH PART I-OCEANOGRAPHIC RESEARCH PAPERS, 2001, 48 (11) :2373-2395
[6]   Nitrogen modulates phytoplankton growth in spring in the South China Sea [J].
Chen, YLL ;
Chen, HY ;
Karl, DM ;
Takahashi, M .
CONTINENTAL SHELF RESEARCH, 2004, 24 (4-5) :527-541
[7]  
DEBRA AW, 2002, ANLA CHIMICA ACTA, V453, P21
[8]   DETERMINATION OF PHOSPHORUS IN AQUEOUS-SOLUTION VIA FORMATION OF THE PHOSPHOANTIMONYLMOLYBDENUM BLUE COMPLEX - REEXAMINATION OF OPTIMUM CONDITIONS FOR THE ANALYSIS OF PHOSPHATE [J].
DRUMMOND, L ;
MAHER, W .
ANALYTICA CHIMICA ACTA, 1995, 302 (01) :69-74
[9]   A high sensitivity, low volume HPLC method to determine soluble reactive phosphate in freshwater and saltwater [J].
Haberer, JL ;
Brandes, JA .
MARINE CHEMISTRY, 2003, 82 (3-4) :185-196
[10]   MAGIC - A SENSITIVE AND PRECISE METHOD FOR MEASURING DISSOLVED PHOSPHORUS IN AQUATIC ENVIRONMENTS [J].
KARL, DM ;
TIEN, G .
LIMNOLOGY AND OCEANOGRAPHY, 1992, 37 (01) :105-116