Axial compression behavior of laced cold-formed steel built-up columns with unstiffened angle sections

被引:40
作者
Dar, M. Adil [1 ]
Sahoo, Dipti Ranjan [1 ]
Jain, Arvind K. [1 ]
机构
[1] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
关键词
Lacing; Built-up columns; Cold-formed sections; Failure; Numerical modelling; Strength; I-SECTION; CHANNEL SECTIONS; STRENGTH; DESIGN; BEAMS;
D O I
10.1016/j.jcsr.2019.105727
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There are numerous parameters that influence the behavior of built-up steel columns. This paper reports an experimental investigation carried out on cold-formed steel (CFS) built-up columns composed of four unstiffened CFS equal angle sections connected by lacings intermittently along their heights. The man parameters varied in the test specimens were the width of end plate, the lacing slenderness ratio, the chord flat width-to-thickness ratio and the lacing configurations. Six pin-ended test specimens were tested under monotonically increasing concentric axial loading. The test result output viz ultimate column strengths, load vs. displacement response, mode of failure, and deformed shapes were used to investigate the effect of above-mentioned parameters on the axial behavior of CFS built-up laced columns. The current standards for CFS structures were used to predict the column strengths for the sake of comparison. Furthermore, a numerical validation of the test results was carried out using a finite element software ABAQUS. Test results indicate that the lacing slenderness, the lacing configuration, and the end plate width affect the column behavior in CFS laced built-up columns significantly. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:14
相关论文
共 38 条
[1]  
ABAQUS, 2004, ABAWUS US MAN VERS 6
[2]   Elastic buckling analysis of cold-formed steel built-up sections with discrete fasteners using the compound strip method [J].
Abbasi, M. ;
Khezri, M. ;
Rasmussen, K. J. R. ;
Schafer, B. W. .
THIN-WALLED STRUCTURES, 2018, 124 :58-71
[3]   Behaviour of cold-formed steel built-up I-section columns composed of four U-profiles [J].
Anbarasu, M. ;
Venkatesan, M. .
ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (03) :613-625
[4]   Experimental study on cold-formed steel web stiffened lipped channel columns undergoing distortional-global interaction [J].
Anbarasu, M. ;
Murugapandian, G. .
MATERIALS AND STRUCTURES, 2016, 49 (04) :1433-1442
[5]  
[Anonymous], 2005, IS16082005
[6]  
[Anonymous], [No title captured]
[7]  
[Anonymous], 2006, EC313
[8]  
[Anonymous], 2018, ADV CONCR STRUCT GEO
[9]  
[Anonymous], 2005, EC311
[10]  
ASTM, 2009, ASTM A653/A653M-09