Method for fabrication of microfluidic systems in glass

被引:156
作者
Stjernstrom, M [1 ]
Roeraade, J [1 ]
机构
[1] Royal Inst Technol, Dept Analyt Chem, S-10044 Stockholm, Sweden
关键词
D O I
10.1088/0960-1317/8/1/006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this report we describe a new way of fabricating integrated microfluidic elements in glass. By employing a matrix of underpinning posts and a thin wall, surrounding etched flow channels, an efficient sealing of glass chips substrates to thin cover glass can be accomplished. The use of this arrangement enables the overlay sheath of glass to hermetically close the flow channel by fusion bonding while avoiding problems with void or crack formation that are due to dust particles, non-planarity and differences in thermal coefficient of expansion. As an example a structure with a thin cover glass, useful for studying phenomena in capillary electrophoresis utilizing large numerical aperture microscope lenses, was fabricated.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 25 条
[1]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[2]   CHARACTERIZATION OF THE ELECTROSTATIC BONDING OF SILICON AND PYREX GLASS [J].
COZMA, A ;
PUERS, B .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1995, 5 (02) :98-102
[3]   MANIPULATION OF SAMPLE FRACTIONS ON A CAPILLARY ELECTROPHORESIS CHIP [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2284-2287
[4]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[5]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[6]   Integrated capillary electrophoresis devices with an efficient postcolumn reactor in planar quartz and glass chips [J].
Fluri, K ;
Fitzpatrick, G ;
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4285-4290
[7]  
Harendt C., 1992, Journal of Micromechanics and Microengineering, V2, P113, DOI 10.1088/0960-1317/2/3/001
[8]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[9]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[10]   CAPILLARY ARRAY ELECTROPHORESIS USING LASER-EXCITED CONFOCAL FLUORESCENCE DETECTION [J].
HUANG, XHC ;
QUESADA, MA ;
MATHIES, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :967-972