Electrochemical mitigation of hydrogen sulfide in deep-pit swine manure storage

被引:18
作者
Ding, Lingkan [1 ]
Lin, Hongjian [2 ]
Hetchler, Brian [1 ]
Wang, Yuchuan [1 ]
Wei, Wei [3 ]
Hu, Bo [1 ]
机构
[1] Univ Minnesota, Dept Bioprod & Biosyst Engn, 1390 Eckles Ave, St Paul, MN 55108 USA
[2] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310058, Peoples R China
[3] Metropolitan State Univ, Depanment Math & Stat, 700 East 7th St, St Paul, MN 55106 USA
关键词
Deep-pit swine manure storage; Hydrogen sulfide; Pilot-scale demonstration; Electrochemical treatment; Low carbon steel; LIVESTOCK BUILDINGS; PART I; SULFATE; GENERATION; EMISSIONS; OXIDATION; CORROSION; SYSTEMS;
D O I
10.1016/j.scitotenv.2021.146048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hydrogen sulfide (H2S) is a toxic and hazardous gas and is commonly present in livestock operations, which occasionally causes associated exposure accidents. This study evaluated the effectiveness of electrochemical control of H2S in lab-scale swine manure storage using different electrode materials, and further selected suitable materials to demonstrate the performance of a pilot-scale field test in the deep-pit manure storage of a 200-head swine barn. In the lab-scale test, electrochemical sulfide oxidation mainly contributed to the H2S mitigation, resulting in high H2S removal efficiencies when using low carbon steel (LCS) and stainless steel 304 (SS304) as electrodes. Based on their better H2S treatment performance and lower material costs, LCS and SS304 were selected for the pilot-scale test. In a 92-day operation, the pilot-scale demonstration showed H2S removal efficiencies of 84.0% and 63.5% for LCS and SS304, respectively. A techno-economic assessment indicated that the installation and operation of the electrochemical system accounted for 16% of barn construction cost using LCS as electrodes. Further optimization may substantially decrease the electrode material consumption and the overall cost. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Electrochemical removal of hydrogen sulfide from swine manure
    Wang, Yuchuan
    Lin, Hongjian
    Hu, Bo
    CHEMICAL ENGINEERING JOURNAL, 2019, 356 : 210 - 218
  • [2] Air quality of swine wean-finish facilities with deep-pit and pull-plug-lagoon manure storage systems
    Zhao, L. Y.
    Manuzon, R.
    Brugger, M.
    Arnold, C.
    Bender, Roger
    Livestock Environment VII, Proceedings, 2005, : 207 - 215
  • [3] Asphyxiation Incidents by Hydrogen Sulfide at Manure Storage Facilities of Swine Livestock Farms in Korea
    Park, Jihoon
    Kang, Taesun
    Jin, Suhyun
    Heo, Yong
    Kim, Kyungran
    Lee, Kyungsuk
    Tsai, Perngjy
    Yoon, Chungsik
    JOURNAL OF AGROMEDICINE, 2016, 21 (02) : 144 - 148
  • [4] Odorous compounds sources and transport from a swine deep-pit finishing operation: A case study
    Trabue, Steven
    Scoggin, Kiwood
    Tyndall, John
    Sauer, Thomas
    Hernandez-Ramirez, Guillermo
    Pfeiffer, Richard
    Hatfield, Jerry
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2019, 233 : 12 - 23
  • [5] PARTIAL BIOFILTRATION OF EXHAUST AIR FROM A HYBRID VENTILATED DEEP-PIT SWINE FINISHER BARN
    Hoff, S. J.
    Harmon, J. D.
    Chen, L.
    Janni, K. A.
    Schmidt, D. R.
    Nicolai, R. E.
    Jacobson, L. D.
    APPLIED ENGINEERING IN AGRICULTURE, 2009, 25 (02) : 269 - 280
  • [6] Effects of Treated Manure Conditions on Ammonia and Hydrogen Sulfide Emissions from a Swine Finishing Barn Equipped with Semicontinuous Pit Recharge System in Summer
    Wi, Jisoo
    Lee, Seunghun
    Kim, Eunjong
    Lee, Myeongseong
    Koziel, Jacek A.
    Ahn, Heekwon
    ATMOSPHERE, 2020, 11 (07)
  • [7] A TWO-STAGE WOOD CHIP-BASED BIOFILTER SYSTEM TO MITIGATE ODORS FROM A DEEP-PIT SWINE BUILDING
    Chen, L.
    Hoff, S. J.
    APPLIED ENGINEERING IN AGRICULTURE, 2012, 28 (06) : 893 - 901
  • [8] Interaction effects of hydrogen sulfide and ammonia on anaerobic digestion of swine manure
    Zhou, HD
    Cheung, PW
    Hacker, R
    PROCEEDINGS OF THE WORLD ENGINEERS' CONVENTION 2004: VOL D, ENVIRONMENT PROTECTION AND DISASTER MITIGATION, 2004, : 125 - 131
  • [9] Empirical model of odor emission from deep-pit swine finishing barns to derive a standardized odor emission factor
    Schauberger, Guenther
    Lim, Teng-Teeh
    Ni, Ji-Qin
    Bundy, Dwaine S.
    Haymore, Barry L.
    Diehl, Claude A.
    Duggirala, Ravi K.
    Heber, Albert J.
    ATMOSPHERIC ENVIRONMENT, 2013, 66 : 84 - 90
  • [10] Hydrogen sulfide production from stored liquid swine manure: A laboratory study
    Arogo, J
    Zhang, RH
    Riskowski, GL
    Day, DL
    TRANSACTIONS OF THE ASAE, 2000, 43 (05): : 1241 - 1245