A Preliminary Investigation on MEMS Based Immunosensor for E. coli O157:H7 Detection

被引:0
|
作者
Abu Bakar, M. H. [1 ]
Ibrahim, M. H. [1 ]
Kassim, N. M. [1 ]
Mohammad, A. B. [1 ]
机构
[1] Univ Teknol Malaysia, Ctr Photon Technol, Fac Elect Engn, Skudai 81310, Johor, Malaysia
来源
2009 IEEE 9TH MALAYSIA INTERNATIONAL CONFERENCE ON COMMUNICATIONS (MICC) | 2009年
关键词
MEMS; Microcantilever; Piezoresistive; Immunosensor; Escherichia coli; O157:H7; Surface stress; Biosensor; antibodies; bacteria; detection; PLASMON RESONANCE BIOSENSOR; MICROCANTILEVER; CANTILEVERS; OUTBREAK; SENSORS;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Bio-recognition layers on sensors can be designed in various ways; however the most popular approach is to immobilise antibodies for specific capture of analytes also known as immunosensor. This paper presents a preliminary study on MEMS based immunosensor for detecting Escherichia coli O157:H7. In this paper, the recent progress within biosensors for E. coli O157:H7 detection will be reviewed. We will discuss the strengths and limitations of current sensor technologies for the detection of E. coli O157:H7. This paper explores the previous methods that have been employed to detect E. coli O157:H7 based on their detection scheme, detection limit, and response time. The reasons focusing on sensor utilizing specifically defined microcantilever using piezoresistive detection scheme is also discussed. We will also explain briefly on the theoretical aspects governing the relation between surface stress and the bending of the microcantilever.
引用
收藏
页码:51 / 54
页数:4
相关论文
共 50 条
  • [1] Sharp Transition in the Immunoimmobilization of E. coli O157:H7
    Celikkol-Aydin, Sukriye
    Suo, Zhiyong
    Yang, Xinghong
    Ince, Bahar
    Avci, Recep
    LANGMUIR, 2014, 30 (26) : 7755 - 7761
  • [2] Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor
    Asgari, Sara
    Dhital, Rajiv
    Aghvami, S. Ali
    Mustapha, Azlin
    Zhang, Yi
    Lin, Mengshi
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [3] A Novel Activated Biochar-Based Immunosensor for Rapid Detection of E. coli O157:H7
    Sobhan, Abdus
    Jia, Fei
    Kelso, Lisa Cooney
    Biswas, Sonatan Kumar
    Muthukumarappan, Kasiviswanathan
    Cao, Changyong
    Wei, Lin
    Li, Yanbin
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [4] Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples
    Mishra, Kundan Kumar
    Dhamu, Vikram Narayanan
    Jophy, Chesna
    Muthukumar, Sriram
    Prasad, Shalini
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [5] A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7
    Dastider, Shibajyoti Ghosh
    Barizuddin, Syed
    Dweik, Majed
    Almasri, Mahmoud
    RSC ADVANCES, 2013, 3 (48): : 26297 - 26306
  • [6] Evaluation of different micro/nanobeads used as amplifiers in QCM immunosensor for more sensitive detection of E. coli O157:H7
    Jiang, Xuesong
    Wang, Ronghui
    Wang, Yun
    Su, Xiaoli
    Ying, Yibin
    Wang, Jianping
    Li, Yanbin
    BIOSENSORS & BIOELECTRONICS, 2011, 29 (01) : 23 - 28
  • [7] Label free polyaniline based impedimetric biosensor for detection of E. coli O157:H7 Bacteria
    Chowdhury, Ankan Dutta
    De, Amitabha
    Chaudhuri, Chirosree Roy
    Bandyopadhyay, Krishnan
    Sen, Pintu
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 916 - 923
  • [8] Dendrimeric biosensor for detection of E. coli O157:H7 in diet
    Shende, Pravin
    Kasture, Pooja
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (02): : 5128 - 5131
  • [9] Magnetoresistive immunosensor for the detection of Escherichia coli O157:H7 including a microfluidic network
    Mujika, M.
    Arana, S.
    Castano, E.
    Tijero, M.
    Vilares, R.
    Ruano-Lopez, J. M.
    Cruz, A.
    Sainz, L.
    Berganza, J.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) : 1253 - 1258
  • [10] Application of Immunomagnetic Separation to E. coli O157: H7 Detection
    Tang Qian-qian
    Wang Jian-ping
    Ye Zun-zhong
    Gai Ling
    Ying Yi-bin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (10) : 2614 - 2618