BOLTED CONNECTIONS SUBJECT TO SHEAR-OUT OR COMBINED BEARING AND SHEAR-OUT FAILURES

被引:0
|
作者
Teh, Lip H. [1 ]
Uz, Mehmet E. [2 ]
机构
[1] Univ Wollongong, Sch Civil Min & Environm Engn, Wollongong, NSW, Australia
[2] ARC Res Hub Australian Steel Mfg, Wollongong, NSW, Australia
来源
STEEL AND ALUMINIUM STRUCTURES | 2016年
关键词
Bolted connections; Bearing strength; Shear-out; Connection capacity; Combined bearing and shear-out; Tear-out; STRENGTH; BEHAVIOR; PLANES;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper points out that the ultimate load capacity of a serial bolted connection failing in combined bearing and shear-out cannot he computed as the simple sum of the respective ultimate bearing and ultimate shear-out capacities. It first describes an accurate equation for determining the ultimate shear-out capacity of a hot-rolled steel bolted connection. The shear-out equation is verified against independent laboratory test results, and are compared against equations specified in the American, European and Canadian steel design specifications. The various assumptions embedded in the existing equations, some optimistic and others pessimistic, are identified. The paper also presents an accurate hearing coefficient for a hot-rolled steel bolted connection. Based on the accurate shear out equation and the hearing coefficient determined by the authors, a design equation is proposed for determining the combined bearing and shear-out capacity of a serial bolted connection in hot-rolled steel plates. The proposed equation is demonstrated through verification against independent laboratory test results to be significantly more accurate than the simple sum.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Push-out tests on embedded shear connections for hybrid girders with trapezoidal web
    Jager, B.
    Nemeth, G.
    Kovacs, N.
    Kovesdi, B.
    Kachichian, M.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 581 - 586
  • [42] Shear lag and eccentricity effects of bolted connections in cold-formed steel sections
    Teh, Lip H.
    Yazici, Veysel
    ENGINEERING STRUCTURES, 2013, 52 : 536 - 544
  • [43] Experimental and analytical studies on the deformability of a precast RC shear wall involving bolted connections
    Sun Jian
    Qiu HongXing
    Yang Yuan
    Lu Bo
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2015, 58 (08) : 1439 - 1448
  • [44] Push-out tests on bolted shear connectors in composite cold-formed steel beams
    Hosseinpour, Mahmoud
    Zeynalian, Mehran
    Ataei, Abdoreza
    Daei, Maryam
    THIN-WALLED STRUCTURES, 2021, 164
  • [45] Improving the shear strength of bolted connections in pultruded GFRP using glass fiber sheets
    Nhut Phan Viet
    Yoresta, Fengky Satria
    Kitane, Yasuo
    Hashimoto, Kunitaro
    Matsumoto, Yukihiro
    COMPOSITE STRUCTURES, 2021, 255
  • [46] Experimental and numerical study of undersized shear panel dampers with bolted connections
    Zhao, Huatian
    Shi, Gang
    Li, Shuailing
    Zhang, Naizhou
    Zhuang, Shanxiang
    Zhu, Bin
    ENGINEERING STRUCTURES, 2023, 280
  • [47] Structural performance on bolted sleeved connections between two CFS channel sections subjected to combined bending and shear
    Natesan, Vijayakumar
    Madhavan, Mahendrakumar
    STRUCTURES, 2019, 20 : 794 - 812
  • [48] Experimental investigation into stud shear connections under combined shear and tension forces
    Shen, M. H.
    Chung, K. F.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 133 : 434 - 447
  • [49] Experimental study on wire and arc additively manufactured steel double-shear bolted connections
    Liu, Yunyi
    Ye, Jun
    Yang, Yuanzhang
    Quan, Guan
    Wang, Zhen
    Zhao, Weijian
    Zhao, Yang
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [50] Investigation of pipe shear connectors using push out test
    Nasrollahi, Saeed
    Maleki, Shervin
    Shariati, Mahdi
    Marto, Aminaton
    Khorami, Majid
    STEEL AND COMPOSITE STRUCTURES, 2018, 27 (05) : 537 - 543