Effects of the Level of Mono-Segmental Dynamic Stabilization on the Whole Lumbar Spine

被引:14
作者
Choi, Hae Won [1 ]
Kim, Young Eun [1 ]
Chae, Soo-Won [2 ]
机构
[1] Dankook Univ, Dept Mech Engn, 152 Jukjeon Ro, Yongin 16890, Gyeonggi Do, South Korea
[2] Korea Univ, Dept Mech Engn, 145 Anam Ro, Seoul 02841, South Korea
基金
新加坡国家研究基金会;
关键词
Finite element spine model; Dynamic stabilization; Fusion; Instrumentation level; Adjacent segment degeneration; OF-THE-LITERATURE; FINITE-ELEMENT; MECHANICAL-PROPERTIES; INTRADISCAL PRESSURE; ADJACENT SEGMENTS; MOTION ANALYSIS; FUSION; DEGENERATION; LIGAMENTS; RESPONSES;
D O I
10.1007/s12541-016-0073-1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Little biomechanical data has been gathered for the biomechanical effects of pedicle-based dynamic stabilization system (PBDS) and fusion (a conventional titanium rod and cage) to the whole lumbar spine according to the instrumentation level. A previously validated three-dimensional, intact osteoligamentous L1-S1 finite element model was modified to incorporate three different PBDS (Dynesys, Nflex, or PEEK) and fusion at three different levels (L3-L4, L4-L5, and L5-S1). A new loading method that can create the segmental motion similar to an in-vivo measurement was applied to the model. The biomechanical changes in the stabilized models were compared with those of the intact model during sagittal plane motion. The simulation results demonstrated that Dynesys generated relatively larger motion when it was instrumented at the L3-L4 segment, whereas the Nflex was the most appropriate device for L4-L5 stabilization. Depending on the stabilization device and instrumented level, whole-lumbar segmental motion also varied. During flexion, stabilization at the L3-L4 level or L4-L5 level produced a relatively higher increase in the motion at all cranial levels. Stabilization at the L5-S1 level generated a slight decrease in the motion at the adjacent cranial level without respect to the type of fixation. In cases of fusion, the change in the motion was higher relative to that with PBDS. Given the biomechanical change at each level after stabilization, adjacent segment degeneration was expected cranially rather caudally, and the probability of this degeneration differed depending on the stabilization level and device.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 39 条
  • [1] EFFECTS OF FLUID INJECTION ON MECHANICAL-PROPERTIES OF INTERVERTEBRAL DISKS
    ANDERSSON, GBJ
    SCHULTZ, AB
    [J]. JOURNAL OF BIOMECHANICS, 1979, 12 (06) : 453 - 458
  • [2] Posterior Pedicle Fixation-based Dynamic Stabilization Devices for the Treatment of Degenerative Diseases of the Lumbar Spine
    Bono, Christopher M.
    Kadaba, Murali
    Vaccaro, Alexander R.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (05): : 376 - 383
  • [3] Influence of different fusion techniques in lumbar spine over the adjacent segments: A 3D finite element study
    Cegonino, Jose
    Calvo-Echenique, Andrea
    Perez-del Palomar, Amaya
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (07) : 993 - 1000
  • [4] Immediate biomechanical effects of lumbar posterior dynamic stabilization above a circumferential fusion
    Cheng, Boyle C.
    Gordon, Jeff
    Cheng, Joseph
    Welch, William C.
    [J]. SPINE, 2007, 32 (23) : 2551 - 2557
  • [5] Cunningham Bryan W, 2004, Spine J, V4, p219S, DOI 10.1016/j.spinee.2004.07.015
  • [6] A non-optimized follower load path may cause considerable intervertebral rotations
    Dreischarf, Marcel
    Zander, Thomas
    Bergmann, Georg
    Rohlmann, Antonius
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (13) : 2625 - 2628
  • [7] A Computational Biomechanical Investigation of Posterior Dynamic Instrumentation: Combination of Dynamic Rod and Hinged (Dynamic) Screw
    Erbulut, Deniz U.
    Kiapour, Ali
    Oktenoglu, Tunc
    Ozer, Ali F.
    Goel, Vijay K.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (05):
  • [8] Ghiselli G, 2003, SPINE, V28, P1275
  • [9] Lumbar-pelvic coordination is influenced by lifting task parameters
    Granata, KP
    Sanford, AH
    [J]. SPINE, 2000, 25 (11) : 1413 - 1418
  • [10] Moment-rotation responses of the human lumbosacral spinal column
    Guan, Yabo
    Yoganandan, Narayan
    Moore, Jason
    Pintar, Frank A.
    Zhang, Jiangyue
    Maiman, Dennis J.
    Laud, Purushottam
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (09) : 1975 - 1980