Impact of Soft Tissue Imbalance on Knee Flexion Angle After Posterior Stabilized Total Knee Arthroplasty

被引:9
作者
Tsukada, Sachiyuki [1 ]
Fujii, Tomoko [2 ,3 ]
Wakui, Motohiro [1 ]
机构
[1] Nekoyama Miyao Hosp, Dept Orthopaed Surg, Niigata, Niigata, Japan
[2] Kyoto Univ, Grad Sch Med, Epidemiol & Prevent Serv, Kyoto, Kyoto, Japan
[3] Japan Soc Promot Sci, Chiyoda Ku, Kojimachi Business Ctr Bldg, Tokyo, Japan
基金
日本学术振兴会;
关键词
knee; primary arthroplasty; soft tissue balance; range of motion; tensor device; PERIARTICULAR INJECTION; PAIN-CONTROL; EPIDURAL ANALGESIA; CONDYLAR OFFSET; SATISFACTION; REPLACEMENT; GAP; OSTEOARTHRITIS; PROSTHESIS; TENSION;
D O I
10.1016/j.arth.2017.03.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study was performed to assess the impact of soft tissue imbalance on the knee flexion angle 2 years after posterior stabilized total knee arthroplasty (TKA). Methods: A total of 329 consecutive varus knees were included to assess the association of knee flexion angle 2 years after TKA with preoperative, intraoperative, and postoperative variables. All intraoperative soft tissue measurements were performed by a single surgeon under spinal anesthesia in a standardized manner including the subvastus approach, reduced patella, and without use of a pneumonic tourniquet. Results: Multiple linear regression analysis showed no significant correlations in terms of intraoperative valgus imbalance at 90-degree flexion or the difference in soft tissue tension between 90-degree flexion and 0-degree extension (beta = -0.039; 95% confidence interval [CI], -0.88 to 0.80; P = .93 and beta = 0.015; 95% CI, -0.29 to 0.32; P = .92, respectively). Preoperative flexion angle was significantly correlated with knee flexion angle 2 years after TKA (beta = 0.42; 95% CI, 0.33 to 0.51; P < .0001). Conclusion: Avoiding valgus imbalance at 90-degree flexion and aiming for strictly equal soft tissue tension between 90-degree flexion and 0-degree extension had little practical value with regard to knee flexion angle 2 years after posterior stabilized TKA. (C) 2017 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:2399 / 2403
页数:5
相关论文
共 23 条
  • [1] Soft-tissue tension total knee arthroplasty
    Asano, H
    Hoshino, A
    Wilton, TJ
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (05) : 558 - 561
  • [2] TIBIAL OSTEOTOMY IN GONARTHROSIS (OSTEO-ARTHRITIS OF KNEE)
    BAUER, GCH
    INSALL, J
    KOSHINO, T
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1969, A 51 (08) : 1545 - &
  • [3] Influence of posterior condylar offset on knee flexion after cruciate-sacrificing mobile-bearing total knee replacement A prospective analysis of 410 consecutive cases
    Bauer, T.
    Biau, D.
    Colmar, M.
    Poux, X.
    Hardy, P.
    Lortat-Jacob, A.
    [J]. KNEE, 2010, 17 (06) : 375 - 380
  • [4] Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset
    Bellemans, J
    Banks, S
    Victor, J
    Vandenneucker, H
    Moemans, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 50 - 53
  • [5] Increased satisfaction after total knee replacement using sensor-guided technology
    Gustke, K. A.
    Golladay, G. J.
    Roche, M. W.
    Jerry, G. J.
    Elson, L. C.
    Anderson, C. R.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (10) : 1333 - 1338
  • [6] The influence of posterior condylar offset on knee flexion after total knee replacement using a cruciate-sacrificing mobile-bearing implant
    Hanratty, B. M.
    Thompson, N. W.
    Wilson, R. K.
    Beverland, D. E.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (07): : 915 - 918
  • [7] Hino K, 2016, KNEE SURG S IN PRESS
  • [8] THE POSTERIOR STABILIZED CONDYLAR PROSTHESIS - A MODIFICATION OF THE TOTAL CONDYLAR DESIGN - 2-YEAR TO 4-YEAR CLINICAL-EXPERIENCE
    INSALL, JN
    LACHIEWICZ, PF
    BURSTEIN, AH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) : 1317 - 1323
  • [9] Factors Influencing Patient Satisfaction Two to Five Years After Primary Total Knee Arthroplasty
    Jacobs, Cale A.
    Christensen, Christian P.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (06) : 1189 - 1191
  • [10] Range of motion of standard and high-flexion posterior stabilized total knee prostheses
    Kim, YH
    Sohn, KS
    Kim, JS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (07) : 1470 - 1475