Assessment of left ventricular ejection fraction with cardiofocal collimators: Comparison between IQ-SPECT, planar equilibrium radionuclide angiography, and cardiac magnetic resonance

被引:13
作者
Pelletier-Galarneau, Matthieu [1 ]
Finnerty, Vincent [1 ]
Tan, Stephanie [1 ]
Authier, Sebastien [1 ]
Gregoire, Jean [1 ]
Harel, Francois [1 ]
机构
[1] Montreal Heart Inst, Dept Radiol & Nucl Med, 5000 Belanger, Montreal, PQ H1T 1C8, Canada
关键词
Radionuclide angiography; Left ventricular function; Gated blood pool imaging; Collimation; BLOOD-POOL SPECT; TIME; VALIDATION; REDUCTION; VOLUMES;
D O I
10.1007/s12350-018-1251-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background IQ-SPECT has been shown to significantly reduce acquisition time and administered dose while preserving image quality in myocardial perfusion imaging. Whether IQ-SPECT provides accurate left ventricular ejection fractions (LVEF) with gated blood pool SPECT (GBPS) remains unknown. Methods Sixty patients underwent IQ-SPECT GBPS and planar imaging. Among those patients, 11 underwent both cMRI and GBPS. GBPS LVEF, LVEDV, and LVESV were calculated using 2 validated software; QBS (Cedars-Sinai Medical Center, Los Angeles, USA) and MHI (Montreal Heart Institute, Montreal, Canada). LVEF, LVEDV, and LVESV obtained with the different modalities were compared. Results Average planar LVEF was 48 +/- 11% (mean +/- SD), average LVEDV was 177 +/- 59 mL (range 63 to 342 mL), and average LVESV was 96 +/- 46 mL (range 16 to 234 mL). GBPS LVEF and their correlation coefficient with planar LVEF were 40 +/- 12% (r = 0.70) and 44 +/- 12% (r = 0.83) with QBS and MHI, respectively. Correlation coefficient between cMRI and planar LVEF was 0.65 and were 0.69 and 0.52 between cMRI and GBPS using QBS and MHI, respectively. Conclusions LVEF calculated with GBPS using IQ-SPECT correlates with planar measurements. Correlation is best using the MHI method and variation is independent of LVEDV.
引用
收藏
页码:1857 / 1864
页数:8
相关论文
共 26 条
[1]   Evaluation of patients with coronary artery disease IQ-SPECT protocol in myocardial perfusion imaging: Preliminary results [J].
Caobelli, F. ;
Pizzocaro, C. ;
Paghera, B. ;
Guerra, U. P. .
NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2013, 52 (05) :178-185
[2]   Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT [J].
Caobelli, Federico ;
Thackeray, James T. ;
Soffientini, Alberto ;
Bengel, Frank M. ;
Pizzocaro, Claudio ;
Guerra, Ugo Paolo .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (12) :1920-1928
[3]   IQ SPECT Allows a Significant Reduction in Administered Dose and Acquisition Time for Myocardial Perfusion Imaging: Evidence from a Phantom Study [J].
Caobelli, Federico ;
Kaiser, Stefano Ren ;
Thackeray, James T. ;
Bengel, Frank M. ;
Chieregato, Matteo ;
Soffientini, Alberto ;
Pizzocaro, Claudio ;
Savelli, Giordano ;
Galelli, Marco ;
Guerra, Ugo Paolo .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (12) :2064-2070
[4]   Prevention and treatment of cardiomyopathy and heart failure in patients receiving Cancer Chemotherapy [J].
Cardinale D. ;
Colombo A. ;
Cipolla C.M. .
Current Treatment Options in Cardiovascular Medicine, 2008, 10 (6) :486-495
[5]   Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography [J].
Chen, Yi-Chieh ;
Ko, Chi-Lun ;
Yen, Rouh-Fang ;
Lo, Mei-Fang ;
Huang, Yih-Hwen ;
Hsu, Pei-Ying ;
Wu, Yen-Wen ;
Cheng, Mei-Fang .
JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (03) :348-361
[6]   Advances in SPECT camera software and hardware: Currently available and new on the horizon [J].
DePuey, E. Gordon .
JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (03) :551-581
[7]   Qualitative and quantitative comparison of gated blood pool single photon emission computed tomography using low-energy high-resolution and SMARTZOOM collimation [J].
Erwin, William D. ;
Jessop, Aaron C. ;
Mar, Martha V. ;
Macapinlac, Homer A. ;
Mawlawi, Osama R. .
NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (01) :35-43
[8]  
Everaert H, 1998, EUR J NUCL MED, V25, P3
[9]  
FABER TL, 1989, J NUCL MED, V30, P638
[10]   How to use cardiac IQ.SPECT routinely? An overview of tips and tricks from practical experience to the literature [J].
Gremillet, Eric ;
Agostini, Denis .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (04) :707-710