Impact of left atrial size on isolation area in the acute phase of pulmonary vein isolation using 28mm cryoballoon

被引:3
作者
Chikata, Akio [1 ,2 ]
Kato, Takeshi [3 ]
Usuda, Kazuo [1 ]
Fujita, Shuhei [4 ]
Maruyama, Michiro [1 ]
Nagata, Yoshiki [1 ]
Sakagami, Satoru [2 ]
Kanamori, Naomi [2 ]
Yaegashi, Takanori [2 ]
Saeki, Takahiro [2 ]
Kusayama, Takashi [3 ]
Usui, Soichiro [3 ]
Furusho, Hiroshi [3 ]
Kaneko, Shuichi [3 ]
Takamura, Masayuki [3 ]
机构
[1] Toyama Prefectural Cent Hosp, Dept Internal Med, Div Cardiol, Toyama, Japan
[2] Natl Hosp Org, Kanazawa Med Ctr, Dept Cardiol, Kanazawa, Ishikawa, Japan
[3] Kanazawa Univ, Grad Sch Adv Prevent Med Sci, Dept Syst Biol, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
[4] Toyama Prefectural Cent Hosp, Dept Pediat, Toyama, Japan
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2018年 / 41卷 / 07期
关键词
atrial fibrillation; cryoballoon; isolation area; pulmonary vein isolation; radiofrequency ablation; RADIOFREQUENCY CATHETER ABLATION; CONTACT-FORCE; 2ND-GENERATION CRYOBALLOON; FIBRILLATION; METAANALYSIS; CRYOABLATION; ANATOMY; TRIAL;
D O I
10.1111/pace.13337
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe impact of left atrial (LA) size on isolation area (ISA) using a 28-mm second-generation cryoballoon (CB) in the acute phase after pulmonary vein isolation (PVI) and the differences of CB from contact force-guided radiofrequency (RF) ablation have not been fully investigated. MethodsWe examined 85 consecutive patients (CB group, 35; RF group, 50) with drug-refractory paroxysmal atrial fibrillation who underwent their first PVI procedure at two institutions. We evaluated ISA after PVI using 3D-Merge computed tomography images (GE Healthcare, Little Chalfont, UK) and high-resolution electroanatomical mapping. ResultsTotal ISA was significantly smaller in the CB group (20.66.0 cm(2)) than in the RF group (29.0 +/- 7.1 cm(2); P<0.0001). In the CB group, ISA of the left pulmonary vein (LPV), right pulmonary vein (RPV), and total ISA were not correlated with the left atrial surface area (LASA). The ratios of ISA to LASA (%ISA) of LPV and total ISA negatively correlated with LASA in the CB group (LPV: r=-0.4001, P=0.0173; total ISA: r=-0.4733, P=0.0041). In contrast, in the RF group, ISA of LPV, RPV, and total ISA positively correlated with LASA; (LPV: r=0.5155, P=0.001; RPV: r=0.6398, P<0.0001; total ISA: r=0.7299, P<0.0001). ConclusionISA created using CB was significantly smaller than that using RF and did not change regardless of LASA increment. Differences in ISA between the two groups became more prominent in the large atrium.
引用
收藏
页码:700 / 706
页数:7
相关论文
共 21 条
[1]   Three-dimensional analysis of pulmonary venous ostial and antral anatomy: Implications for balloon catheter-based pulmonary vein isolation [J].
Ahmed, J ;
Sohal, S ;
Malchano, ZJ ;
Holmvang, G ;
Ruskin, JN ;
Reddy, VY .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (03) :251-255
[2]   High-Resolution Mapping of Scar-Related Atrial Arrhythmias Using Smaller Electrodes With Closer Interelectrode Spacing [J].
Anter, Elad ;
Tschabrunn, Cory M. ;
Josephson, Mark E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (03) :537-545
[3]   Cryoballoon versus Radiofrequency Catheter Ablation in Atrial Fibrillation: A Meta-Analysis [J].
Cardoso, Rhanderson ;
Mendirichaga, Rodrigo ;
Fernandes, Gilson ;
Healy, Chris ;
Lambrakos, Litsa K. ;
Viles-Gonzalez, Juan F. ;
Goldberger, Jeffrey J. ;
Mitrani, Raul D. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (10) :1151-1159
[4]   The long-term efficacy of cryoballoon vs irrigated radiofrequency ablation for the treatment of atrial fibrillation: A meta-analysis [J].
Cheng, Xiaocheng ;
Hu, Qiongwen ;
Zhou, Changyue ;
Liu, Lin Qiong ;
Chen, Tong ;
Liu, Zengzhang ;
Tang, Xuewen .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 181 :297-302
[5]   Anatomical extent of pulmonary vein isolation after cryoballoon ablation for atrial fibrillation: comparison between the 23 and 28 mm balloons [J].
Chierchia, Gian B. ;
de Asmundis, Carlo ;
Sorgente, Antonio ;
Paparella, Gaetano ;
Sarkozy, Andrea ;
Muller-Burri, Stephan-Andreas ;
Capulzini, Lucio ;
Yazaki, Yoshinao ;
Brugada, Pedro .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2011, 12 (03) :162-166
[6]   General anesthesia improves contact force and reduces gap formation in pulmonary vein isolation: a comparison with conscious sedation [J].
Chikata, Akio ;
Kato, Takeshi ;
Yaegashi, Takanori ;
Sakagami, Satoru ;
Kato, Chieko ;
Saeki, Takahiro ;
Kawai, Keiichi ;
Takashima, Shin-ichiro ;
Murai, Hisayoshi ;
Usui, Soichiro ;
Furusho, Hiroshi ;
Kaneko, Shuichi ;
Takamura, Masayuki .
HEART AND VESSELS, 2017, 32 (08) :997-1005
[7]   Optimal Force-Time Integral for Pulmonary Vein Isolation According to Anatomical Wall Thickness Under the Ablation Line [J].
Chikata, Akio ;
Kato, Takeshi ;
Sakagami, Satoru ;
Kato, Chieko ;
Saeki, Takahiro ;
Kawai, Keiichi ;
Takashima, Shin-ichiro ;
Murai, Hisayoshi ;
Usui, Soichiro ;
Furusho, Hiroshi ;
Kaneko, Shuichi ;
Takamura, Masayuki .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (03)
[8]   Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures [J].
Ciconte, Giuseppe ;
Velagic, Vedran ;
Mugnai, Giacomo ;
Saitoh, Yukio ;
Irfan, Ghazala ;
Hunuk, Burak ;
Stroker, Erwin ;
Conte, Giulio ;
Sieira, Juan ;
Di Giovanni, Giacomo ;
Baltogiannis, Giannis ;
Brugada, Pedro ;
de Asmundis, Carlo ;
Chierchia, Gian-Battista .
EUROPACE, 2016, 18 (01) :71-77
[9]   Importance of nonpulmonary vein foci in catheter ablation for paroxysmal atrial fibrillation [J].
Hayashi, Kentaro ;
An, Yoshimori ;
Nagashima, Michio ;
Hiroshima, Kenichi ;
Ohe, Masatsugu ;
Makihara, Yu ;
Yamashita, Kennosuke ;
Yamazato, Schoichiro ;
Fukunaga, Masato ;
Sonoda, Koichiro ;
Ando, Kenji ;
Goya, Masahiko .
HEART RHYTHM, 2015, 12 (09) :1918-1924
[10]   Quantification of the cryoablation zone demarcated by pre- and postprocedural electroanatomic mapping in patients with atrial fibrillation using the 28-mm second-generation cryoballoon [J].
Kenigsberg, David N. ;
Martin, Natalia ;
Lim, Hae W. ;
Kowalski, Marcin ;
Ellenbogen, Kenneth A. .
HEART RHYTHM, 2015, 12 (02) :283-290