A Comprehensive Study of Ultrasound Transducer Characteristics in Microscopic Ultrasound Neuromodulation

被引:25
作者
Gougheri, Hesam Sadeghi [1 ]
Dangi, Ajay [2 ]
Kothapalli, Rajasekhar [2 ,3 ]
Kiani, Mehdi [1 ]
机构
[1] Penn State Univ, Dept Elect Engn, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Biomed Engn, University Pk, PA 16802 USA
[3] Penn State Coll Med, Penn State Hershey Canc Inst, Hershey, PA 17033 USA
基金
美国国家卫生研究院;
关键词
Transducers; Ultrasonic imaging; Acoustics; Spatial resolution; Acoustic beams; Neuromodulation; Energy efficiency; Brain; figure-of-merit; microscopic ultrasound stimulation; neuromodulation; spatial resolution; transcranial focused ultrasound stimulation; ultrasound transducer; BRAIN-STIMULATION; HIGH-FREQUENCY; DESIGN; NERVE;
D O I
10.1109/TBCAS.2019.2922027
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to improve the spatial resolution of transcranial focused ultrasound stimulation (tFUS), we have recently proposed microscopic ultrasound stimulation (US). In US, either an electronically phased array of ultrasound transducers or several millimeter-sized focused transducers are placed on the brain surface or sub-millimeter-sized transducers are implanted inside the brain tissue to steer and deliver a focused ultrasound pressure directly to the neural target. A key element in both tFUS and US is the ultrasound transducer that converts electrical power to acoustic pressure. The literature lacks a comprehensive study (in a quantitative manner) of the transducer characteristics, such as dimension, focusing, acoustic matching, backing material, and sonication frequency (f(p)), in the US. This paper studies the impact of these design parameters on the acoustic beam profile of millimeter-sized transducers with the emphasis on the stimulation spatial resolution and energy efficiency, which is defined as the US figure-of-merit (FoM). For this purpose, disc-shaped focused and unfocused piezoelectric (PZT-5A) transducers with different dimension (diameter, thickness), backing material (PCB, air) and acoustic matching in the frequency range of 2.2-9.56MHz were fabricated. Our experimental studies with both water and sheep brain phantom medium demonstrate that acoustically matched focused transducers with high quality factor are desirable for US, as they provide fine spatial resolution and high acoustic intensities with low input electrical power levels (i.e., high FoM).
引用
收藏
页码:835 / 847
页数:13
相关论文
共 39 条
[1]  
[Anonymous], 2012, THESIS
[2]  
[Anonymous], 2012, UNDERSTANDING ULTRAS
[3]  
Barker AT, 1999, EEG CL N SU, P3
[4]   Microscopic magnetic stimulation of neural tissue [J].
Bonmassar, Giorgio ;
Lee, Seung Woo ;
Freeman, Daniel K. ;
Polasek, Miloslav ;
Fried, Shelley I. ;
Gale, John T. .
NATURE COMMUNICATIONS, 2012, 3
[5]  
Boyden E., 2011, BIOL REP, V3
[6]   Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications [J].
Cannata, JM ;
Ritter, TA ;
Chen, WH ;
Silverman, RH ;
Shung, KK .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (11) :1548-1557
[7]   Primordial black holes and associated gravitational waves in axion monodromy inflation [J].
Cheng, Shu-Lin ;
Lee, Wolung ;
Ng, Kin-Wang .
JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS, 2018, (07)
[8]   Non-invasive peripheral nerve stimulation via focused ultrasound in vivo [J].
Downs, Matthew E. ;
Lee, Stephen A. ;
Yang, Georgiana ;
Kim, Seaok ;
Wang, Qi ;
Konofagou, Elisa E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)
[9]   A Study on Design Model of Interactive Service of Mobile Commerce - An example of Tsannkuen Retail [J].
Feng, Chung-Shun ;
Hsiao, Ming-Yu ;
Tsai, Chia-Wen .
PROCEEDINGS OF THE 2019 5TH INTERNATIONAL CONFERENCE ON E-BUSINESS AND APPLICATIONS (ICEBA 2019), 2019, :1-5
[10]   ACOUSTIC TRANSMISSION FACTOR THROUGH THE RAT SKULL AS A FUNCTION OF BODY MASS, FREQUENCY AND POSITION [J].
Gerstenmayer, Matthieu ;
Fellah, Benjamin ;
Magnin, Remi ;
Selingue, Erwan ;
Larrat, Benoit .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (11) :2336-2344