3D Exoscope System in Neurosurgery-Comparison of a Standard Operating Microscope With a New 3D Exoscope in the Cadaver Lab

被引:59
作者
Herlan, Stephan [1 ]
Marquardt, Jakob S. [3 ]
Hirt, Bernhard [2 ]
Tatagiba, Marcos [1 ]
Ebner, Florian H. [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Neurosurg, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Eberhard Karls Univ Tubingen, Inst Clin Anat & Cell Anal, Tubingen, Germany
[3] Asklepios Klin Nord, Dept Neurosurg, Hamburg, Germany
关键词
3D exoscope; Ergonomics; Operating microscope; Visual field; Visualization; Microsurgery; Microscope; Stereoscopy; ASSISTED BRAIN SURGERY; CLINICAL-EXPERIENCE; EVOLUTION; SKILLS;
D O I
10.1093/ons/opz081
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: For decades, the operating microscope has been the "gold standard" visualization device in neurosurgery. The development of endoscopy revolutionized different surgical disciplines, whereas in neurosurgery, the endoscope is commonly used as an additional device more than as single visualization tool. Invention of a 3D exoscope system opens new possibilities in visualization and ergonomics in neurosurgery. OBJECTIVE: To assess the prototype of a 3D exoscope (3D exoscope, year of manufacture 2015, FA Aesculap, Tuttlingen, Germany) as neurosurgical visualization device in comparison to a standard operating microscope. METHODS: A pterional approach was performed in 3 ETOH-fixed specimens (6 sides). A standard operating microscope was compared to a 3D exoscope prototype. Dimensions like visual field, magnification, illumination, ergonomics, depth effect, and 3D impression were compared. RESULTS: In all approaches, the structures of interest could be clearly visualized with both devices. Magnification showed similar results. The exoscope had more magnification potential, whereas the visual quality got worse in higher magnification levels. The illumination showed better results in the microscope. Surgeons felt more comfortable with the 3D exoscope, concerning ergonomic considerations. Depth effect and 3D impression showed similar results. None of the surgeons felt uncomfortable using the exoscope. CONCLUSION: The operating microscope is the gold standard visualization tool in neurosurgery because of its illumination, stereoscopy, and magnification. Nevertheless, it causes ergonomic problems. The prototype of a 3D exoscope showed comparable features in visual field, stereoscopic impression, and magnification, with a clear benefit concerning the ergonomic possibilities.
引用
收藏
页码:518 / 524
页数:7
相关论文
共 32 条
[1]   Clinical experience with a high definition exoscope system for surgery of pineal region lesions [J].
Birch, Kurtis ;
Drazin, Doniel ;
Black, Keith L. ;
Williams, James ;
Berci, George ;
Mamelak, Adam N. .
JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (07) :1245-1249
[2]   Three-dimensional endoscopic sinus surgery: Feasibility and technical aspects [J].
Brown, Seth M. ;
Tabaee, Abtin ;
Singh, Ameet ;
Schwartz, Theodore H. ;
Anand, Vijay K. .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2008, 138 (03) :400-402
[3]   Balancing the Shortcomings of Microscope and Endoscope: Endoscope-Assisted Technique in Microsurgical Removal of Recurrent Epidermoid Cysts in the Posterior Fossa [J].
Ebner, F. H. ;
Roser, F. ;
Thaher, F. ;
Schittenhelm, J. ;
Tatagiba, M. .
MINIMALLY INVASIVE NEUROSURGERY, 2010, 53 (5-6) :218-222
[4]   Broadening horizons of neuroendoscopy with a variable-view rigid endoscope: An anatomical study [J].
Ebner, F. H. ;
Marquardt, J. S. ;
Hirt, B. ;
Feigl, G. C. ;
Tatagiba, M. ;
Schuhmann, M. U. .
EJSO, 2010, 36 (02) :195-200
[5]   Actual state of EndActive ventricular endoscopy [J].
Ebner, Florian H. ;
Hirt, Bernhard ;
Marquardt, Jakob S. ;
Herlan, Stephan ;
Tatagiba, Marcos ;
Schuhmann, Martin U. .
CHILDS NERVOUS SYSTEM, 2012, 28 (01) :87-91
[6]   Optimum view distance for laparoscopic surgery [J].
El Shallaly, G. ;
Cuschieri, A. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (12) :1879-1882
[7]   Neuroendoscopy: General Aspects and Principles [J].
Esposito, Felice ;
Cappabianca, Paolo .
WORLD NEUROSURGERY, 2013, 79 (02) :S14.e7-S14.e9
[8]   Endoscope-assisted brain surgery: Part 2 - Analysis of 380 procedures [J].
Fries, G ;
Perneczky, A .
NEUROSURGERY, 1998, 42 (02) :226-231
[9]   Skills Comparison in Pediatric Residents Using a 2-Dimensional versus a 3-Dimensional High-Definition Camera in a Pediatric Laparoscopic Simulator [J].
Guana, Riccardo ;
Ferrero, Luisa ;
Garofalo, Salvatore ;
Cerrina, Alessia ;
Cussa, Davide ;
Arezzo, Alberto ;
Schleef, Jurgen .
JOURNAL OF SURGICAL EDUCATION, 2017, 74 (04) :644-649
[10]  
Hopf NJ, 2013, INNOV NEUROSURG, V1, P125