Resonance damping in array cable systems by wind turbine active filtering in large offshore wind power plants

被引:20
作者
Kocewiak, Lukasz Hubert [1 ]
Kramer, Birte Laudal Ohlenschlaeger [1 ]
Holmstrom, Ole [1 ]
Jensen, Kim Hoj [2 ]
Shuai, Lei [2 ]
机构
[1] DONG Energy Wind Power, Elect Syst Anal, Fredericia, Denmark
[2] Siemens Wind Power, Lyngby, Denmark
关键词
wind power; offshore installations; wind turbines; active filters; power harmonic filters; power cables; damping; power grids; power convertors; power system stability; power transformers; harmonic distortion; resonance damping; array cable systems; wind turbine active filtering; large offshore wind power plants; large offshore WPP; harmonic emission; harmonic mitigation methods; widespread medium-voltage cable system; offshore grid transformers; low-frequency parallel resonances; harmonic voltage distortion; point of common coupling; grid-side converters; harmonic rejection; harmonic stability; system robustness; noise rejection;
D O I
10.1049/iet-rpg.2016.0111
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The application of active filtering in large offshore wind power plants (WPPs) is presented in this study. The harmonic challenges such as sources of harmonic emission and resonances are identified and briefly explained. Also modern remedial harmonic mitigation methods as of active filtering are described and their application in real-life WPP systems demonstrated. It is underlined that WPP components such as widespread medium-voltage cable system and offshore grid transformers can introduce significant low-frequency parallel resonances which can cause a significant harmonic voltage distortion at the point of common coupling. Active filtering in modern grid-side converters used in wind turbines is applied simultaneously keeping sufficient harmonic/noise rejection. Extensive harmonic stability studies are also shown to prove the overall system robustness.
引用
收藏
页码:1069 / 1077
页数:9
相关论文
共 21 条
[1]  
Akhmatov V., 2008, P 7 INT WORKSH LARG
[2]  
Andresen B, 2012, Europe Patent, Patent No. [2630510 A1, 2360510]
[3]  
Brantsaetera H, 2015, ENERG ENVIRON SCI, P1
[4]  
Brogan P., 2010, EPE WIND EN CHAPT SE
[5]  
Brogan P., 2012, 11 INT WORKSHOP LARG
[6]  
Emin Z., 2016, CIGRE BIENN SESS CIG, pC4
[7]  
Franklin G.F., 2006, Digital Control of Dynamic Systems, V3
[8]  
Freijedo F. D., 2015, POWERTECH
[9]  
Glasdam J., 2014, CIGR PAR SESS PAR
[10]  
Jones R, 2008, Patent US, Patent No. [2008/00622728 A1, 200800622728]