Intraoperative detection of traumatic coagulopathy using the activated coagulation time

被引:12
作者
Aucar, JA
Norman, P
Whitten, E
Granchi, TS
Liscum, KR
Wall, MJ
Mattox, KL
机构
[1] Univ Missouri, Dept Surg, MC 418, Columbia, MO 65212 USA
[2] Baylor Coll Med, Dept Anesthesiol, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
来源
SHOCK | 2003年 / 19卷 / 05期
关键词
injury; coagulation; activated clotting time; damage control; shock; resuscitation;
D O I
10.1097/01.shk.0000048905.46342.6b
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Traumatic coagulopathy manifests as a hypocoagulable state associated with hypothermia, acidosis, and coagulation factor dilution. The diagnosis must be made clinically because traditional coagulation tests are neither sensitive nor specific and take too long to be used for intraoperative monitoring. We hypothesized that the activated coagulation time (ACT) would reflect the global coagulation status of traumatized patients and would become elevated as coagulation reserves become exhausted. A prospective protocol was used to study 31 victims of major trauma who underwent immediate surgical intervention. Victims of major head trauma were excluded and patients were selected at random over an 8-month period. At least two serial intraoperative blood samples were obtained at 15-min intervals via indwelling arterial catheters. A Hemochron model 801 coagulation monitor was used to measure the ACT. Of the 31 patients studied, 7 became clinically coagulopathic and 24 did not. The ACT measurements of coagulopathic and noncoagulopathic trauma patients were significantly different by multiple statistical comparisons. Both groups differed from normal, nontraumatized patients. The coagulopathic trauma patients had significantly elevated values when compared with other trauma patients or to normal values. We conclude that a low ACT reflects the initial hypercoagulability associated with major trauma and an elevated ACT is an objective indicator that the coagulation system reserve is near exhaustion. An elevated ACT may represent an indication for considering damage control maneuvers or more aggressive resuscitation.
引用
收藏
页码:404 / 407
页数:4
相关论文
共 26 条
[1]  
Collins JA, 1991, TXB SURG BIOL BASIS, P91
[2]   Predicting life-threatening coagulopathy in the massively transfused trauma patient: Hypothermia and acidoses revisited [J].
Cosgriff, N ;
Moore, EE ;
Sauaia, A ;
KennyMoynihan, M ;
Burch, JM ;
Galloway, B .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (05) :857-861
[3]   COMPARISON OF ACTIVATED COAGULATION LIME AND WHOLE-BLOOD HEPARIN MEASUREMENTS WITH LABORATORY PLASMA ANTI-XA HEPARIN CONCENTRATION IN PATIENTS HAVING CARDIAC OPERATIONS [J].
DESPOTIS, GJ ;
SUMMERFIELD, AL ;
JOIST, JH ;
GOODNOUGH, LT ;
SANTORO, SA ;
SPITZNAGEL, E ;
COX, JL ;
LAPPAS, DG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 108 (06) :1076-1082
[4]   HYPOTHERMIA AND ACIDOSIS WORSEN COAGULOPATHY IN THE PATIENT REQUIRING MASSIVE TRANSFUSION [J].
FERRARA, A ;
MACARTHUR, JD ;
WRIGHT, HK ;
MODLIN, IM ;
MCMILLEN, MA .
AMERICAN JOURNAL OF SURGERY, 1990, 160 (05) :515-518
[5]   The logistics of damage control [J].
Granchi, TS ;
Liscum, KR .
SURGICAL CLINICS OF NORTH AMERICA, 1997, 77 (04) :921-&
[6]  
GRAVLEE GP, 1990, ANESTH ANALG, V71, P549
[7]  
Hattersley P., 1966, JAMA-J AM MED ASSOC, V196, P150
[8]  
HATTERSLEY PG, 1976, AM J CLIN PATHOL, V66, P899
[9]   ARTIFACTUAL PROLONGATION OF THE ACTIVATED PARTIAL THROMBOPLASTIN TIME MIMICKING A COAGULOPATHY - A LESSON RELEARNED [J].
HUMPHRIES, JE ;
ACKER, MN ;
SCHNELL, DE ;
KNARR, JW .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 100 (02) :108-110
[10]  
*INT TECHN CORP, 1993, ACT CLOTT TIM PACK I