Simultaneous Determination of Copper, Lead, and Cadmium at Hexagonal Mesoporous Silica Immobilized Quercetin Modified Carbon Paste Electrode

被引:27
作者
Xia, Fangquan [1 ]
Zhang, Xin [1 ]
Zhou, Changli [1 ]
Sun, Danzi [1 ]
Dong, Yanmin [1 ]
Liu, Zhen [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Shandong, Peoples R China
来源
JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY | 2010年
关键词
NANOSTRUCTURED ELECTROCHEMICAL SENSORS; ADSORPTIVE STRIPPING VOLTAMMETRY; TEMPERATURE IONIC LIQUIDS; SELF-ASSEMBLED MONOLAYER; TRACE; ACCUMULATION; METALS; SAMMS; FILM;
D O I
10.1155/2010/824197
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method was developed for simultaneous determination of copper, lead, and cadmium, based on their voltammetric response at a carbon paste electrode modified with hexagonal mesoporous silica (HMS) immobilized quercetin (HMS-Qu/CPE). Compared with quercetin modified carbon paste electrode (Qu/CPE) and quercetin ionic liquid modified carbon paste electrode (Qu-IL/CPE), the HMS-Qu/CPE exhibited improved selectivity and high sensitivity toward the detection of copper, lead, and cadmium. The properties of the HMS-Qu/CPE in 0.1 MHCOONa-HCl buffer solution (pH4.7) were investigated by adsorptive stripping voltammetry (ASV) and electrochemical impedance spectroscopy (EIS). The electrochemical behavior of copper, lead, and cadmium at the modified electrodes and factors affecting the preconcentration procedures were also investigated. Detection limits of 5.0, 0.8, 1.0 nM for copper, lead, and cadmium were obtained, respectively. The method is simple, fast, sensitive, and selective, and is successfully applied to soil sample.
引用
收藏
页数:6
相关论文
共 31 条
[1]   VOLTAMMETRIC DETERMINATION OF TRACE-METALS AND ORGANICS AFTER ACCUMULATION AT MODIFIED ELECTRODES [J].
ARRIGAN, DWM .
ANALYST, 1994, 119 (09) :1953-1966
[2]   Non-haloaluminate room-temperature ionic liquids in electrochemistry - A review [J].
Buzzeo, MC ;
Evans, RG ;
Compton, RG .
CHEMPHYSCHEM, 2004, 5 (08) :1106-1120
[3]   Use of room temperature ionic liquids in gas sensor design [J].
Buzzeo, MC ;
Hardacre, C ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4583-4588
[4]  
*ENV PROT ADM CHIN, 2002, AN METH WAT WAST MON
[5]  
Fei JJ, 2001, CHINESE J ANAL CHEM, V29, P916
[6]  
FEI JJ, 2001, J ANAL SCI, V17, P375
[7]   ELECTROANALYSIS WITH CHEMICALLY MODIFIED ELECTRODES [J].
GUADALUPE, AR ;
ABRUNA, HD .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :142-149
[8]   Trace detection of 2,4,6-trinitrotoluene in the gaseous phase by cyclic voltammetry [J].
Krausa, M ;
Schorb, K .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 461 (1-2) :10-13
[9]   Electrode modified with ionic liquid covalently bonded to silicate matrix for accumulation of electroactive anions [J].
Lesniewski, Adam ;
Niedziolka, Joanna ;
Palys, Barbara ;
Rizzi, Cecile ;
Gaillon, Laurent ;
Opallo, Marcin .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (10) :2580-2584
[10]   Study on the fluorescence properties of benzopyrylium salt in Ti-HMS [J].
Li, DM ;
Zhang, JL ;
Anpo, M .
DYES AND PIGMENTS, 2004, 63 (01) :71-76