Prevention of transfusion of platelet components contaminated with low levels of bacteria:: a comparison of bacteria culture and pathogen inactivation methods

被引:47
作者
Nussbaumer, Walter
Allersdorfer, Doris
Grabmer, Christoph
Rheinschmidt, Margaret
Lin, Lily
Schonitzer, Diether
Lass-Florl, Cornelia
机构
[1] Univ Innsbruck Hosp, Dept Transfus Med, Apheresis Div, A-6020 Innsbruck, Austria
[2] Univ Innsbruck, Inst Hyg & Social Med, Dept Transfus Med, A-6020 Innsbruck, Austria
[3] Cerus Corp, Concord, CA USA
关键词
D O I
10.1111/j.1537-2995.2007.01247.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: This study compared the efficacy of bacterial detection with inactivation for reducing the risk associated with transfusion of platelet (PLT) components contaminated with low levels of bacteria. STUDY DESIGN AND METHODS: Twenty-one double-dose PLTs were spiked with seven species of bacteria at three levels (0.003-0.03, 0.03-0.3, 0.3-3 colony-forming units [CFUs]/mL). After split, each PLT unit contained 1 to 10, 10 to 100, and 100 to 1000 CFUs. One unit was photochemically treated (PCT, 150 mu mol/L amotosalen and 3 J/cm(2) ultraviolet A). The other unit was untreated. All units were stored and sampled on Days 1, 2, and 5 of storage for aerobic and anaerobic culture in the BacT/ALERT system (bioMerieux). PLTs were classified as sterile when no bacterial growth was detected after 120 hours of culture. RESULTS: In all PCT PLTs, no bacteria were detected throughout 5 days of storage regardless of species, level of contamination, and sampling time. In untreated PLTs, Staphylococcus aureus was consistently detected by culturing. Growth of 1 to 10 CFUs per unit Staphylococcus epidermidis, 1 to 100 CFUs per unit of Klebsiella pneumoniae, and 1 to 1000 CFUs per unit Propionibacterium acnes was delayed and only detectable after 5, 2, and 5 days of storage, respectively. Low levels of Streptococcus agalactiae (1-10 CFUs/unit), Escherichia coli (1-100 CFUs/unit), and Clostridium perfringens (1-100 CFUs/unit) were not detected during 5 days of storage, although bacterial outgrowth was detected at higher levels of contamination. CONCLUSIONS: For the seven bacterial species examined, contaminated PLTs may be released for transfusion on test-negative-to-date status. In contrast, bacterial inactivation by PCT could reduce the risk associated with transfusion of PLTs contaminated with low levels of these bacteria.
引用
收藏
页码:1125 / 1133
页数:9
相关论文
共 43 条
[1]   TRANSFUSION-RELATED SEPSIS AFTER PROLONGED PLATELET STORAGE [J].
ANDERSON, KC ;
LEW, MA ;
GORGONE, BC ;
MARTEL, J ;
LEAMY, CB ;
SULLIVAN, B .
AMERICAN JOURNAL OF MEDICINE, 1986, 81 (03) :405-411
[2]  
Arendt A., 2005, Morbidity and Mortality Weekly Report, V54, P168
[3]   ESCHERICHIA-COLI SEPSIS FROM CONTAMINATED PLATELET TRANSFUSION [J].
ARNOW, PM ;
WEISS, LM ;
WEIL, D ;
ROSEN, NR .
ARCHIVES OF INTERNAL MEDICINE, 1986, 146 (02) :321-324
[4]   Bacterial contamination of cellular blood components: risks, sources and control [J].
Blajchman, MA .
VOX SANGUINIS, 2004, 87 :98-103
[5]   Growth of bacteria in inoculated platelets: implications for bacteria detection and the extension of platelet storage [J].
Brecher, ME ;
Holland, PV ;
Pineda, AA ;
Tegtmeier, GE ;
Yomtovian, R .
TRANSFUSION, 2000, 40 (11) :1308-1312
[6]   Bacterial contamination of blood components [J].
Brecher, ME ;
Hay, SN .
CLINICAL MICROBIOLOGY REVIEWS, 2005, 18 (01) :195-+
[7]   Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms [J].
Brecher, ME ;
Means, N ;
Jere, CS ;
Heath, D ;
Rothenberg, S ;
Stutzman, LC .
TRANSFUSION, 2001, 41 (04) :477-482
[8]   Evaluation of a new generation of plastic culture bottles with an automated microbial detection system for nine common contaminating organisms found in PLT components [J].
Brecher, ME ;
Hay, SN ;
Rothenberg, SJ .
TRANSFUSION, 2004, 44 (03) :359-363
[9]   Monitoring of apheresis platelet bacterial contamination with an automated liquid culture system: a university experience [J].
Brecher, ME ;
Hay, SN ;
Rothenberg, SJ .
TRANSFUSION, 2003, 43 (07) :974-978
[10]   Feasibility of implementing an automated culture system for bacteria screening in platelets in the blood bank routine [J].
Castro, E ;
Bueno, JL ;
Barea, L ;
González, R .
TRANSFUSION MEDICINE, 2005, 15 (03) :185-195