Numerical investigation of moisture removal and energy consumption of porous body affected by EHD

被引:20
作者
Dolati, F. [1 ]
Amanifard, N. [1 ]
Deylami, H. M. [2 ]
机构
[1] Univ Guilan, Dept Mech Engn, Fac Engn, Rasht, Iran
[2] Univ Guilan, Fac Engn & Technol, Rudsar, Iran
关键词
Electrohydrodynamics; Drying; Numerical study; Porous body; Segmented plate collectors; HEAT-TRANSFER ENHANCEMENT; AIR-FLOW; CORONA DISCHARGE; MASS-TRANSFER; CHANNEL; SLICES; FIELD; SIMULATION; VOLTAGE; SYSTEM;
D O I
10.1016/j.energy.2018.04.143
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the convective drying rate of a porous body driven by Electrohydrodynamics (EHD) was numerically investigated. Two different types of collecting electrode were compared: wall plate collector and segmented plate collector. Firstly, wall plate collector was examined and compared with non-EHD case. The numerical results showed that the moisture removal in the wall plate collector was 5 times higher than the non-EHD case. Secondly, the wall plate collector was replaced with a segmented plate collector. Different arrangements, as well as the various vertical distances between the emitter and the collectors, were examined to find a higher mass transfer. The numerical results showed that moisture removal in the segmented collector in the most appropriate conditions was about 3 times greater than the wall plate collector case. Finally, to gain a more general conclusion, the specific energy consumption (SEC) and pressure loss of all cases were evaluated. The results indicated that the pressure loss has increased greatly by using the EHD-induced flow. Moreover, it was depicted that for the wall plate collector the SEC reached to 8.2 W-hikg when it decreased to orders of 10(-2) W-h/kg for the segmented collector cases. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:352 / 364
页数:13
相关论文
共 35 条
[1]   Simulation of corona discharge in point-plane configuration [J].
Adamiak, K ;
Atten, P .
JOURNAL OF ELECTROSTATICS, 2004, 61 (02) :85-98
[2]   Effect of process parameters on the EHD airflow [J].
Ahmedou, Sid'Ahmed Ould ;
Havet, Michel .
JOURNAL OF ELECTROSTATICS, 2009, 67 (2-3) :222-227
[3]   Analysis of the EHD Enhancement of Heat Transfer in a Flat Duct [J].
Ahmedou, Sid'Ahmed Ould ;
Havet, Michel .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (02) :489-494
[4]   Comparative Evaluation of the Effects of Electrohydrodynamic, Oven, and Ambient Air on Carrot Cylindrical Slices during Drying Process [J].
Alemrajabi, A. A. ;
Rezaee, F. ;
Mirhosseini, M. ;
Esehaghbeygi, Ali .
DRYING TECHNOLOGY, 2012, 30 (01) :88-96
[5]   A numerical study on drying of porous media [J].
Amanifard, Nima ;
Haghi, Akbar Khodaparast .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2008, 25 (02) :191-198
[6]   Numerical modeling of convective drying of food with spatially dependent transfer coefficient in a turbulent flow field [J].
Ateeque, Md. ;
Udayraj ;
Mishra, Ranjeet K. ;
Chandramohan, V. P. ;
Talukdar, Prabal .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 78 :145-157
[7]   Numerical analysis of electric force influence on heat transfer in a channel flow (theory based on saturated porous medium approach) [J].
Ayuttaya, Suwimon Saneewong Na ;
Chaktranond, Chainarong ;
Rattanadecho, Phadungsak .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 64 :361-374
[8]   Electrohydrodynamic drying of sea cucumber (Stichopus japonicus) [J].
Bai, Yaxiang ;
Qu, Min ;
Luan, Zhongqi ;
Li, Xinjun ;
Yang, Yaxin .
LWT-FOOD SCIENCE AND TECHNOLOGY, 2013, 54 (02) :570-576
[9]   High electric field drying of Japanese radish [J].
Bajgai, TR ;
Hashinaga, F .
DRYING TECHNOLOGY, 2001, 19 (09) :2291-2302
[10]   Transient exergetic efficiency and moisture loss analysis of forced convection drying with and without electrohydrodynamic enhancement2 [J].
Bardy, Erik ;
Hamdi, Merouane ;
Havet, Michel ;
Rouaud, Olivier .