Characterisation of a transparent optical test strip for quantification of water hardness

被引:38
作者
Capitán-Vallvey, LF
Fernández-Ramos, MD
Gálvez, PAD
Santoyo-González, F
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
[2] Univ Granada, Dept Organ Chem, E-18071 Granada, Spain
关键词
hardness determination; optical test strip; ionophore-chromoionophore system; water analysis;
D O I
10.1016/S0003-2670(03)00073-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optical and reversible test strip that uses an ion-exchange mechanism which responds equally to calcium and magnesium and makes it possible to determine water hardness is described. The transparent test strip, made of a polyester sheet, has a circular polymeric film of plasticised poly(vinyl chloride) (PVC) that contains all of the reagents necessary to produce an equal response to calcium and magnesium, namely, a cation-selective neutral ionophore, such as 4,13-[bis(N-adamantylcarbamoyl)-acetyl]-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane, a chromoionophore, such as lipophilised Nile Blue, and potassium tetrakis (4-chlorophenyl)borate as a lipophilic salt, which it is evaluated by absorbance measurement at 655 nm in a standard photometer. All experimental variables that influence test strip response, especially in terms of selectivity and response time, have been studied. The sensor responded linearly to hardness up to 14,800 mg l(-1), in activities, expressed as CaCO3. The detection limit is 1.9 mg l(-1) as CaCO3, the reproducibility intermembrane at a medium level of the range was 7.0%, as R.S.D., of loga(Ca2+/Mg2+) and 2.6% as intramembrane. The procedure was applied to the determination of hardness in different types of waters (tap, well, mineral and spring) validating results against a reference procedure. This proposed method is quick, inexpensive, selective and sensitive and uses only conventional instrumentation. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 36 条
  • [1] SELECTIVITY OF ION-SENSITIVE BULK OPTODES
    BAKKER, E
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1805 - 1812
  • [2] DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES
    BAKKER, E
    WILLER, M
    PRETSCH, E
    [J]. ANALYTICA CHIMICA ACTA, 1993, 282 (02) : 265 - 271
  • [3] Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    Bakker, E
    Buhlmann, P
    Pretsch, E
    [J]. CHEMICAL REVIEWS, 1997, 97 (08) : 3083 - 3132
  • [4] SIMULTANEOUS DETERMINATION OF SODIUM, POTASSIUM, MAGNESIUM AND CALCIUM IN SURFACE, GROUND AND DOMESTIC WATER BY FLOW-INJECTION ANALYSIS
    BASSON, WD
    VANSTADEN, JF
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (05): : 370 - 374
  • [5] USE OF DIODE-ARRAY DETECTORS FOR THE SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM AND MAGNESIUM BY FLOW-INJECTION
    BLANCO, M
    COELLO, J
    GENE, J
    ITURRIAGA, H
    MASPOCH, S
    [J]. ANALYTICA CHIMICA ACTA, 1989, 224 (01) : 23 - 30
  • [6] Simultaneous spectrophotometric determination of calcium and magnesium in mineral waters by means of multivariate partial least-squares regression
    Blasco, F
    MedinaHernandez, MJ
    Sagrado, S
    Fernandez, FM
    [J]. ANALYST, 1997, 122 (07) : 639 - 643
  • [7] Optical test strip for calcium determination based on a neutral ionophore
    Capitán-Vallvey, LF
    Ramos, MDF
    de Cienfuegos-Gálvez, PA
    [J]. ANALYTICA CHIMICA ACTA, 2002, 451 (02) : 231 - 241
  • [8] FOSTER RJ, 1992, ANAL CHEM, V64, P1721
  • [9] Franson M. A. H., 1992, STANDARD METHODS EXA
  • [10] FRESENIUS W, 1988, WATER ANAL, P294