Electrochemical determination of meloxicam in pharmaceutical preparation and biological fluids using oxidized glassy carbon electrodes

被引:14
作者
Farhadi, Khalil [1 ]
Karimpour, Ahmad [1 ]
机构
[1] Urmia Univ, Fac Sci, Dept Chem, Orumiyeh, Iran
关键词
meloxicam; electrochemical determination; stripping; biological fluids;
D O I
10.1248/cpb.55.638
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The adsorptive and electrochemical behaviors of meloxicam (MLC) was investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to 1.0 V vs. Ag/AgCl reference electrode. The resulting electrode showed a good activity to improve the electrochemical response of the drug. MLC was accumulated at an electrochemically activated glassy carbon electrode (phosphate buffer pH 6) in a certain time and then determined by linear sweep voltammetry. The oxidative peak currents showed a linear function in the concentration ranges of 0.02 to 10,um using a 240 s preconcentration time. The preconcentration medium-exchange approach was utilized for the selective determination of the drug in spiked urine and plasma samples with satisfactory results. The recovery values of the proposed method obtained 105% (RSD 2.5%) and 100% (RSD 1.8%) for urine and plasma samples, respectively. Also, the proposed method has been successfully used for determination of MLC in tablets.
引用
收藏
页码:638 / 642
页数:5
相关论文
共 25 条
[1]  
Abd Elbary A, 2001, ANAL LETT, V34, P1175
[2]   Polarographic behaviour of meloxicam and its determination in tablet preparations and spiked plasma [J].
Altinöz, S ;
Nemutlu, E ;
Kir, S .
FARMACO, 2002, 57 (06) :463-468
[3]  
Altiokka G, 2001, PHARMAZIE, V56, P184
[4]   Application of an alkyl-diol silica precolumn in a column-switching system for the determination of meloxicam in plasma [J].
Baeyens, WRG ;
Van der Weken, G ;
D'haeninck, E ;
García-Campaña, AM ;
Vankeirsbilck, T ;
Vercauteren, A ;
Deprez, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) :839-846
[5]   Electrochemical reduction of meloxicam at mercury electrode and its determination in tablets [J].
Beltagi, AM ;
Ghoneim, MM ;
Radi, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (05) :795-801
[6]   ELECTROCHEMICAL-BEHAVIOR OF GLASSY-CARBON ELECTRODES MODIFIED BY ELECTROCHEMICAL OXIDATION [J].
BOWERS, ML ;
YENSER, BA .
ANALYTICA CHIMICA ACTA, 1991, 243 (01) :43-53
[7]   ELECTROCATALYSIS OF PROTON-COUPLED ELECTRON-TRANSFER REACTIONS AT GLASSY-CARBON ELECTRODES [J].
CABANISS, GE ;
DIAMANTIS, AA ;
MURPHY, WR ;
LINTON, RW ;
MEYER, TJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1985, 107 (07) :1845-1853
[8]   LC determination and pharmacokinetics of meloxicam [J].
Dasandi, B ;
Shivaprakash ;
Saroj, H ;
Bhat, KM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (05) :999-1004
[9]   ELECTROCHEMICAL PRETREATMENT OF GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2310-2314
[10]   Spectrophotometric methods for determining meloxicam in pharmaceuticals using batch and flow-injection procedures [J].
García, MS ;
Sánchez-Pedreño, C ;
Albero, MI ;
Martí, J .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2000, 9 (03) :311-316