Electrochemical determination of meloxicam in pharmaceutical preparation and biological fluids using oxidized glassy carbon electrodes

被引:14
作者
Farhadi, Khalil [1 ]
Karimpour, Ahmad [1 ]
机构
[1] Urmia Univ, Fac Sci, Dept Chem, Orumiyeh, Iran
关键词
meloxicam; electrochemical determination; stripping; biological fluids;
D O I
10.1248/cpb.55.638
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The adsorptive and electrochemical behaviors of meloxicam (MLC) was investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to 1.0 V vs. Ag/AgCl reference electrode. The resulting electrode showed a good activity to improve the electrochemical response of the drug. MLC was accumulated at an electrochemically activated glassy carbon electrode (phosphate buffer pH 6) in a certain time and then determined by linear sweep voltammetry. The oxidative peak currents showed a linear function in the concentration ranges of 0.02 to 10,um using a 240 s preconcentration time. The preconcentration medium-exchange approach was utilized for the selective determination of the drug in spiked urine and plasma samples with satisfactory results. The recovery values of the proposed method obtained 105% (RSD 2.5%) and 100% (RSD 1.8%) for urine and plasma samples, respectively. Also, the proposed method has been successfully used for determination of MLC in tablets.
引用
收藏
页码:638 / 642
页数:5
相关论文
共 25 条
  • [1] Abd Elbary A, 2001, ANAL LETT, V34, P1175
  • [2] Polarographic behaviour of meloxicam and its determination in tablet preparations and spiked plasma
    Altinöz, S
    Nemutlu, E
    Kir, S
    [J]. FARMACO, 2002, 57 (06): : 463 - 468
  • [3] Altiokka G, 2001, PHARMAZIE, V56, P184
  • [4] Application of an alkyl-diol silica precolumn in a column-switching system for the determination of meloxicam in plasma
    Baeyens, WRG
    Van der Weken, G
    D'haeninck, E
    García-Campaña, AM
    Vankeirsbilck, T
    Vercauteren, A
    Deprez, P
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) : 839 - 846
  • [5] Electrochemical reduction of meloxicam at mercury electrode and its determination in tablets
    Beltagi, AM
    Ghoneim, MM
    Radi, A
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (05) : 795 - 801
  • [6] ELECTROCHEMICAL-BEHAVIOR OF GLASSY-CARBON ELECTRODES MODIFIED BY ELECTROCHEMICAL OXIDATION
    BOWERS, ML
    YENSER, BA
    [J]. ANALYTICA CHIMICA ACTA, 1991, 243 (01) : 43 - 53
  • [7] ELECTROCATALYSIS OF PROTON-COUPLED ELECTRON-TRANSFER REACTIONS AT GLASSY-CARBON ELECTRODES
    CABANISS, GE
    DIAMANTIS, AA
    MURPHY, WR
    LINTON, RW
    MEYER, TJ
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1985, 107 (07) : 1845 - 1853
  • [8] LC determination and pharmacokinetics of meloxicam
    Dasandi, B
    Shivaprakash
    Saroj, H
    Bhat, KM
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (05) : 999 - 1004
  • [9] ELECTROCHEMICAL PRETREATMENT OF GLASSY-CARBON ELECTRODES
    ENGSTROM, RC
    [J]. ANALYTICAL CHEMISTRY, 1982, 54 (13) : 2310 - 2314
  • [10] Spectrophotometric methods for determining meloxicam in pharmaceuticals using batch and flow-injection procedures
    García, MS
    Sánchez-Pedreño, C
    Albero, MI
    Martí, J
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2000, 9 (03) : 311 - 316