ESTABLISHING DIAGNOSTIC REFERENCE LEVELS FOR CARDIAC COMPUTED TOMOGRAPHY ANGIOGRAPHY IN SAUDI ARABIA

被引:10
|
作者
Alhailiy, Ali B. [1 ,2 ]
Kench, Peter L. [1 ]
McEntee, Mark F. [1 ]
Brennan, Patrick C. [1 ]
Ryan, Elaine A. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, M205,Cumberland Campus,75 East St, Sydney, NSW 2141, Australia
[2] Prince Sattam Bin Abdulaziz Univ, Fac Appl Med Sci, Al Kharj, Saudi Arabia
关键词
CORONARY-ARTERY-DISEASE; RADIATION-EXPOSURE; CT-EXAMINATIONS; REDUCTION;
D O I
10.1093/rpd/ncx306
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Cardiac computed tomography angiography (CCTA) is a commonly used diagnostic imaging tool for cardiovascular disease. Despite constant improvements to imaging technologies, the radiation dose to patients remains a concern when using this procedure. Diagnostic reference levels (DRLs) are used as a trigger to identify and alert individual facilities that are using high doses during CT. This study aims to assess patient radiation dose and establish new national DRLs (NDRL) associated with CCTA in Saudi clinical practices. A structured booklet survey was designed for recording patient and scanning protocols during CCTA procedures. The data were collected retrospectively from the participating centres. NDRLs for CCTA were defined as the 75th and 25th of volumetric CT dose index (CTDIvol) and dose length product (DLP). Specific DRLs based on two main ECG-gating modes were also proposed. Data sets related to 197 CCTAs with a mean weight of 77 kg were analysed in detail. The DRL values for CTDIvol and DLP for prospective gating mode and retrospective gating mode were 29 and 62 mGy and 393 and 1057 mGy cm, respectively. NDRLs for CCTA in Saudi Arabia are comparable or slightly lower than European DRLs due to the current use of dose-saving technology. There are major variations in patient doses during CCTA due to differences in CT scanners, scanning modes and departmental CCTA protocols.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [1] DIAGNOSTIC REFERENCE LEVELS IN CARDIAC COMPUTED TOMOGRAPHY ANGIOGRAPHY: A SYSTEMATIC REVIEW
    Alhailiy, Ali B.
    Brennan, Patrick C.
    McEntee, Mark F.
    Kench, Peter L.
    Ryan, Elaine A.
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 63 - 72
  • [2] Establishing diagnostic reference levels for CT examinations in the south region of Saudi Arabia
    Alashban, Yazeed
    Shubayr, Nasser
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [3] Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt
    Salama, Dina Husseiny
    Vassileva, Jenia
    Mahdaly, Gamal
    Shawki, Mona
    Salama, Ahmad
    Gilley, Debbie
    Rehani, Madan Mohan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 16 - 24
  • [4] DIAGNOSTIC REFERENCE LEVELS OF CARDIAC COMPUTED TOMOGRAPHY ANGIOGRAPHY IN A SINGLE MEDICAL CENTER IN TAIWAN: A 3-Y ANALYSIS
    Chen, Li-Guo
    Wu, Ping-An
    Tu, Hsing-Yang
    Sheu, Ming-Huei
    Huang, Li-Chuan
    RADIATION PROTECTION DOSIMETRY, 2021, 194 (01) : 36 - 41
  • [5] A Review of Diagnostic Reference Levels in Computed Tomography
    Dawd, Jemal Edris
    Ozsahin, Dilber Uzun
    Ozsahin, Ilker
    CURRENT MEDICAL IMAGING, 2022, 18 (06) : 623 - 632
  • [6] Establishment of a local diagnostic reference level for computed tomography chest and abdomen in two different cities in Saudi Arabia
    Ahmed, Amna Mohamed
    Musa, Alamin
    Medani, Afaf
    Mahmoud, Mustafa
    Osman, Hamid
    Elsamani, Mohammed
    Kajoak, Samih
    Alghamdi, Salem Saeed
    Tajaldeen, Abdulrahman
    Hanfi, Mohamed Y.
    Khandaker, Mayeen Uddin
    APPLIED RADIATION AND ISOTOPES, 2024, 204
  • [7] The establishment of computed tomography diagnostic reference levels in Portugal
    Santos, Joana
    Foley, Shane
    Paulo, Graciano
    McEntee, Mark F.
    Rainford, Louise
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (03) : 307 - 317
  • [8] Paediatric diagnostic reference levels for common computed tomography procedures: A systematic review
    Garba, I.
    Engel-Hills, P.
    RADIOGRAPHY, 2025, 31 (01) : 27 - 35
  • [9] Paediatric computed tomography diagnostic reference levels in Africa: A systematic review
    Gyan, Emmanuel
    Subaar, Christiana
    Edusei, George
    Antwi Nyarko, Linda
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025, 72 (01) : 139 - 147
  • [10] A STUDY TO ESTABLISH INTERNATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY
    Vassileva, J.
    Rehani, M.
    Kostova-Lefterova, D.
    Al-Naemi, H. M.
    Al Suwaidi, J. S.
    Arandjic, D.
    Bashier, E. H. O.
    Kodlulovich Renha, S.
    El-Nachef, L.
    Aguilar, J. G.
    Gershan, V.
    Gershkevitsh, E.
    Gruppetta, E.
    Hustuc, A.
    Jauhari, A.
    Kharita, Mohammad Hassan
    Khelassi-Toutaoui, N.
    Khosravi, H. R.
    Khoury, H.
    Kralik, I.
    Mahere, S.
    Mazuoliene, J.
    Mora, P.
    Muhogora, W.
    Muthuvelu, P.
    Nikodemova, D.
    Novak, L.
    Pallewatte, A.
    Pekarovic, D.
    Shaaban, M.
    Shelly, E.
    Stepanyan, K.
    Thelsy, N.
    Visrutaratna, P.
    Zaman, A.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 70 - 80