Single-Use Instrumentation, Cutting Blocks, and Trials Decrease Contamination during Total Knee Arthroplasty: A Prospective Comparison of Navigated and Nonnavigated Cases

被引:11
作者
Mont, Michael A. [1 ]
Johnson, Aaron J. [1 ]
Issa, Kimona [1 ]
Pivec, Robert [1 ]
Blasser, Kurt E. [2 ]
McQueen, David [3 ]
Puri, Lalit [4 ]
Dethmers, Daniel A. [5 ]
Miller, David W. [6 ]
Ireland, Philip H. [7 ]
Shurman, John R. [8 ]
Bonutti, Petter [5 ]
机构
[1] Rubin Inst Adv Orthoped, Ctr Joint Preservat & Replacement, Baltimore, MD 21215 USA
[2] Mayo Clin, Dept Orthoped Surg, Jacksonville, FL 32224 USA
[3] Univ Kansas, Dept Orthoped Surg, Kansas City, KS USA
[4] NW Mem Hosp, Dept Orthoped Surg, Chicago, IL 60611 USA
[5] Bonutti Orthoped Serv LTD, Dept Orthoped Surg, Effingham, IL USA
[6] West End Orthoped Clin, Dept Orthoped Surg, Richmond, VA USA
[7] Indiana Univ, Dept Orthoped Surg, Fishers, IN USA
[8] Univ Kansas, Dept Orthoped Surg, Wichita, KS USA
关键词
total knee arthroplasty; single-use instruments; cutting block; contamination; time saving; INFECTION; REPLACEMENT; SURGERY; HIP; VENTILATION; FLOW;
D O I
10.1055/s-0033-1333664
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this prospective controlled trial was to determine whether decrease in contamination could be achieved in nonnavigated and navigated total knee arthroplasties by replacing traditional saws, cutting blocks, and trials with specialized saws and single-use cutting blocks and trials. Various tray wrapping metrics during total knee arthroplasty were measured in 400 procedures performed by 8 different surgeons at 6 institutions. Instrumentation contamination was determined by counting the number of tray sterility indicators, pans, and instruments that were compromised. The results show that a decrease in contamination was evident in 57% (nonnavigated) and 32% (navigated) fewer compromises of tray sterility indicators, pans, and instruments. Single-use instruments show promising benefits, but further study is needed to confirm safety and efficacy before they can be widely adopted. The authors believe that the use of single-use instruments, cutting guides, and trial implants for total knee arthroplasty will play an increasing role in decreasing operating room contamination and potential deep infections.
引用
收藏
页码:285 / 290
页数:6
相关论文
共 21 条
  • [1] Blom A, 2000, ANN ROY COLL SURG, V82, P405
  • [2] Bonutti PM., 2010, TECHNIQUES KNEE SURG, V9, P249, DOI [10.1097/BTK.0b013e3181ef5246, DOI 10.1097/BTK.0B013E3181EF5246]
  • [3] Patient-related Risk Factors for Postoperative Mortality and Periprosthetic Joint Infection in Medicare Patients Undergoing TKA
    Bozic, Kevin J.
    Lau, Edmund
    Kurtz, Steven
    Ong, Kevin
    Berry, Daniel J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) : 130 - 137
  • [4] Operating Room Ventilation With Laminar Airflow Shows No Protective Effect on the Surgical Site Infection Rate in Orthopedic and Abdominal Surgery
    Brandt, Christian
    Hott, Uwe
    Sohr, Dorit
    Daschner, Franz
    Gastmeier, Petra
    Rueden, Henning
    [J]. ANNALS OF SURGERY, 2008, 248 (05) : 695 - 700
  • [5] Air contamination during skin preparation and draping in joint replacement surgery
    Brown, AR
    Taylor, GJS
    Gregg, PJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01): : 92 - 94
  • [6] Unicompartmental Knee Arthroplasty with Use of Novel Patient-Specific Resurfacing Implants and Personalized Jigs
    Fitz, Wolfgang
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 69 - 76
  • [7] Laryngoscope plastic blades in scheduled general anesthesia patients: a comparative randomized study
    Galinski, Michel
    Catineau, Jean
    Rayeh, Fatima
    Muret, Jane
    Ciebiera, Jean-Pierre
    Plantevin, Frederic
    Foucrier, Arnaud
    Tual, Loic
    Combes, Xavier
    Adnet, Frederic
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2011, 23 (02) : 107 - 112
  • [8] Gupta A, 2009, J Perioper Pract, V19, P148
  • [9] Computer-assisted total knee arthroplasty using patient-specific templating
    Hafez, M. A.
    Chelule, K. L.
    Seedhom, B. B.
    Sherman, K. P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (444) : 184 - 192
  • [10] Does the use of laminar flow and space suits reduce early deep infection after total hip and knee replacement? THE TEN-YEAR RESULTS OF THE NEW ZEALAND JOINT REGISTRY
    Hooper, G. J.
    Rothwell, A. G.
    Frampton, C.
    Wyatt, M. C.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (01): : 85 - 90