CO2 capture in a hollow fiber membrane contactor coupled with ionic liquid: Influence of membrane wetting and process parameters

被引:77
|
作者
Qazi, Sohaib [1 ]
Gomez-Coma, Lucia [2 ]
Albo, Jonathan [2 ]
Druon-Bocquet, Stephanie [1 ]
Irabien, Angel [2 ]
Sanchez-Marcano, Jose [1 ]
机构
[1] Univ Montpellier, Inst Europeen Membranes, UMR 5635, CNRS,ENSCM, Montpellier, France
[2] Univ Cantabria, Chem & Blomol Engn Dept, Av Los Castros, E-39005 Santander, Spain
关键词
CO2; capture; Membrane contactor; Ionic liquid; Membrane wetting; Modelling; POSTCOMBUSTION CARBON CAPTURE; OF-THE-ART; ABSORPTION; SEPARATION; WATER; TEMPERATURE; SIMULATION; PRESSURE; REMOVAL; DIOXIDE;
D O I
10.1016/j.seppur.2019.115986
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The present work demonstrates the potential of coupling ionic liquid 1-ethyl-3-methylimidazolium ethylsulfate ([emim][EtSO4]) and hollow fiber membrane contactors for post-combustion CO2 capture. CO2 absorption experiments in counter-current configuration were carried out, followed by a comprehensive two-dimensional dynamic modeling based on steady state and pseudo-steady state operating modes. The model considers the level of wetting of porous hollow fibers. An overall mass transfer coefficient of 3.99 .10(-5) m s(-1) and CO2 flux 6.1.10(-5) mol m(-2) s(-1) were obtained for 100 ml min(-1) of gas flowing inside the fibers. The model predicted the effects of membrane wetting, porosity, tortuosity, module length, fiber inner diameter, gas and absorbent flow rates. Membrane wetting has a noteworthy effect on CO2 capture efficiency. A smaller amount of wetting can cause a huge resistance in CO2 transport through the membrane. The separation efficiency was enhanced by using membranes with high porosity and low tortuosity and decreased by enhancing the gas flow rate and absorbent flow rate reduction. CO2 capture is enhanced by increasing module length and reduction of inner diameter of fibers.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Numerical Simulation and Analysis of CO2 Removal in a Polypropylene Hollow Fiber Membrane Contactor
    Zhang, Zhien
    Yan, Yunfei
    Zhang, Li
    Ju, Shunxiang
    INTERNATIONAL JOURNAL OF CHEMICAL ENGINEERING, 2014, 2014
  • [42] Effect of PVDF concentration on the morphology and performance of hollow fiber membrane employed as gas-liquid membrane contactor for CO2 absorption
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Duidar, Ali
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 98 : 174 - 185
  • [43] Analysis of CO2 separation and simulation of a partially wetted hollow fiber membrane contactor
    Keshavarz, R.
    Fathikalajahi, J.
    Ayatollahi, S.
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (03) : 1237 - 1247
  • [44] Optimization of Blended Amines for CO2 Absorption in a Hollow-Fiber Membrane Contactor
    Wang, Zhen
    Fang, Mengxiang
    Yan, Shuiping
    Yu, Hai
    Wei, Chiao-Chien
    Luo, Zhongyang
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (34) : 12170 - 12182
  • [45] Biocatalytic PVDF composite hollow fiber membranes for CO2 removal in gas-liquid membrane contactor
    Xu, Yilin
    Lin, Yuqing
    Chew, Nick Guan Pin
    Malde, Chandresh
    Wang, Rong
    JOURNAL OF MEMBRANE SCIENCE, 2019, 572 : 532 - 544
  • [46] Hydrophobic and hydrophilic hollow fiber membranes for Co2 stripping via gas-liquid membrane contactor
    Naim, R.
    Ismail, A. F.
    Mansourizadeh, A.
    EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 328 - 331
  • [47] Polyvinylidene fluoride and polyetherimide hollow fiber membranes for CO2 stripping in membrane contactor
    Naim, Rosma
    Ismail, A. F.
    Cheer, N. B.
    Abdullah, M. S.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2014, 92 (07): : 1391 - 1398
  • [48] Modeling and simulation of the hollow fiber bore size on the CO2 absorption in membrane contactor
    Ghasem, Nayef
    CHEMICAL PRODUCT AND PROCESS MODELING, 2020, 15 (04):
  • [49] Numerical Simulation on Supercritical CO2 Fluid Dynamics in a Hollow Fiber Membrane Contactor
    Valdes, Hugo
    Unda, Kevin
    Saavedra, Aldo
    COMPUTATION, 2019, 7 (01):
  • [50] Mass transfer characteristics of a continuously operated hollow-fiber membrane contactor and stripper unit for CO2 capture
    Nieminen, H.
    Jarvinen, L.
    Ruuskanen, V.
    Laari, A.
    Koiranen, T.
    Ahola, J.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2020, 98