New endoscopes and add-on devices to improve colonoscopy performance

被引:27
作者
Gkolfakis, Paraskevas [1 ,2 ]
Tziatzios, Georgios [1 ,2 ]
Dimitriadis, George D. [1 ,2 ]
Triantafyllou, Konstantinos [1 ,2 ]
机构
[1] Univ Athens, Hepatogastroenterol Unit, Dept Internal Med 2, Propaedeut,Res Inst,Attikon Univ Gen Hosp,Med Sch, 1 Rimini St, Athens 12462, Greece
[2] Univ Athens, Diabet Ctr, Med Sch, Attikon Univ Gen Hosp, 1 Rimini St, Athens 12462, Greece
关键词
Colonoscopy; Quality indicators; Wide-angle view colonoscopes; Add-on devices; ADENOMA DETECTION RATE; ENDOCUFF-ASSISTED COLONOSCOPY; FULL-SPECTRUM ENDOSCOPY; POLYP DETECTION RATE; COLORECTAL-CANCER; MISS RATE; QUALITY INDICATORS; TANDEM COLONOSCOPY; WITHDRAWAL TIMES; DETECTION RATES;
D O I
10.3748/wjg.v23.i21.3784
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Colonoscopy is the gold standard for colorectal cancer prevention; however, it is still an imperfect modality. Precancerous lesions can be lost during screening examinations, thus increasing the risk of interval cancer. A variety of factors either patient-, or endoscopist dependent or even the procedure itself may contribute to loss of lesions. Sophisticated modalities including advanced technology endoscopes and add-on devices have been developed in an effort to eliminate colonoscopy's drawbacks and maximize its ability to detect potentially culprit polyps. Novel colonoscopes aim to widen the field of view. They incorporate more than one cameras enabling simultaneous image transmission. In that way the field of view can expand up to 330 degrees. On the other hand a plethora of add-on devices attachable on the standard colonoscope promise to detect lesions in the proximal aspect of colonic folds either by offering a retrograde view of the lumen or by straightening the haustral folds during withdrawal. In this minireview we discuss how these recent advances affect colonoscopy performance by improving its quality indicators (cecal intubation rate, adenoma detection rate) and other metrics (polyp detection rate, adenomas per colonoscopy, polyp/adenoma miss rate) associated with examination's outcomes.
引用
收藏
页码:3784 / 3796
页数:13
相关论文
共 67 条
  • [51] Prospective Swiss pilot study of Endocuff-assisted colonoscopy in a screening population
    Sawatzki, Mikael
    Meyenberger, Christa
    Marbet, Urs Albert
    Haarer, Johannes
    Frei, Remus
    [J]. ENDOSCOPY INTERNATIONAL OPEN, 2015, 3 (03) : E236 - E239
  • [52] Comparison of Adenoma Detection Rate by a High Definition Colonoscopy versus Standard High Definition Colonoscopy-A Prospective Randomized Multicenter Trial
    Shirin, Haim
    Shpak, Beni
    Epshtein, Julia
    Vilmann, Peter
    Hoffman, Arthur
    Ishaq, Sauid
    Testoni, Pier Alberto
    Sanduleanu, Silvia
    Neumann, Helmut
    Goetz, Martin
    Siersema, Peter D.
    Gross, Seth A.
    Abramowich, Dov
    Shnell, Mati
    Mizrahi, Meir
    Hendel, Jakob
    Viale, Edi
    de Ridder, Rogier
    Pochapin, Mark
    Yair, Michael
    Gluck, Nathan
    Yaari, Shaul
    Stigaard, Trine
    Maliar, Amit
    Moshkowitz, Menachem
    Israeli, Eran
    Matalon, Shai
    Hershcovici, Tiberiu
    Simantov, Roman
    Jacob, Harold
    Shachar, Eyal
    Karstensen, John G.
    Teubner, Daniel
    Bogie, Roel
    Kiesslich, Ralf
    [J]. GASTROINTESTINAL ENDOSCOPY, 2016, 83 (05) : AB192 - AB192
  • [53] Feasibility of full-spectrum endoscopy: Korea's first full-spectrum endoscopy colonoscopic trial
    Song, Jeong-Yeop
    Cho, Youn Hee
    Kim, Mi A.
    Kim, Jeong-Ae
    Lee, Chun Tek
    Lee, Moon Sung
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (08) : 2621 - 2629
  • [54] High definition colonoscopy vs. standard video endoscopy for the detection of colonic polyps: a meta-analysis
    Subramanian, V.
    Mannath, J.
    Hawkey, C. J.
    Ragunath, K.
    [J]. ENDOSCOPY, 2011, 43 (06) : 499 - 505
  • [55] A pilot study to assess the safety and efficacy of the Third Eye Retrograde auxiliary imaging system during colonoscopy
    Triadafilopoulos, G.
    Li, J.
    [J]. ENDOSCOPY, 2008, 40 (06) : 478 - 482
  • [56] Triantafyllou K, 2016, UEG J S1, V2
  • [57] A 13-year time trend analysis of 3724 small bowel video capsule endoscopies and a forecast model during the financial crisis in Greece
    Triantafyllou, Konstantinos
    Gkolfakis, Paraskevas
    Viazis, Nikos
    Tsibouris, Panagiotis
    Tsigaridas, Athanasios
    Apostolopoulos, Periklis
    Anastasiou, John
    Hounda, Eleni
    Skianis, Ioannis
    Katopodi, Konstantina
    Ndini, Xhoela
    Alexandrakis, George
    Karamanolis, Demetrios G.
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2017, 29 (02) : 185 - 191
  • [58] Endocuff-Vision: Impact on Colonoscopist Performance During Screening
    Tsiamoulos, Zacharias P.
    Misra, Ravi
    Bourikas, Leonidas A.
    Rajaratnam, Rameshshanker
    Patel, Kinesh P.
    Thomas-Gibson, Siwan
    Haycock, Adam
    Suzuki, Noriko
    Beintaris, Iosif
    Saunders, Brian P.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2015, 81 (05) : AB209 - AB209
  • [59] Feasibility of a novel colonoscope with extra-wide angle of view: a clinical study
    Uraoka, Toshio
    Tanaka, Shinji
    Oka, Shiro
    Matsuda, Takahisa
    Saito, Yutaka
    Moriyama, Tomohiko
    Higashi, Reiji
    Matsumoto, Takayuki
    [J]. ENDOSCOPY, 2015, 47 (05) : 444 - 448
  • [60] A novel extra-wide-angle-view colonoscope: a simulated pilot study using anatomic colorectal models
    Uraoka, Toshio
    Tanaka, Shinji
    Matsumoto, Takayuki
    Matsuda, Takahisa
    Oka, Shiro
    Moriyama, Tomohiko
    Higashi, Reiji
    Saito, Yutaka
    [J]. GASTROINTESTINAL ENDOSCOPY, 2013, 77 (03) : 480 - 483