Highly selective acetone detector based on a separation channel and semiconductor gas sensor

被引:8
作者
Du, Haiying [1 ]
Sun, Ruizhi [2 ]
Su, Jing [3 ]
Sun, Yanhui [4 ]
Xia, Kaili [1 ]
Cong, Liying [1 ]
Cui, Hemin [5 ]
机构
[1] Dalian Minzu Univ, Coll Mech & Elect Engn, Dalian 116600, Peoples R China
[2] Shenzhen Univ, Coll Informat Engn, Shenzhen 518061, Peoples R China
[3] Dalian Med Univ, Hosp 2, Dalian 116044, Peoples R China
[4] Dalian Minzu Univ, Coll Informat & Commun Engn, Dalian 116600, Peoples R China
[5] Dalian Zhonghuida Sci Instrument Co Ltd, Dalian 116085, Peoples R China
基金
中国国家自然科学基金;
关键词
exhaled acetone; gas chromatography; semiconductor gas sensor; time-sharing conversion switch; BREATH; GC/MS; MS;
D O I
10.1088/1361-6501/abe666
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Acetone is a biomarker of diabetics. The exhaled acetone concentration of diabetics is higher than that of a healthy person. Semiconductor gas sensors provide an accurate non-invasive detection method for low-concentration breath acetone of diabetics, but the their selectivity presents a drawback. In order to detect the concentration of exhaled acetone accurately from exhaled breath, an acetone detector based on a separation channel and semiconductor gas sensors is presented in this paper. Carbon dioxide, acetone, and ethanol were simulated and separated by a gas chromatography (GC) column in the separation channel. The separated time of carbon dioxide, exhaled acetone, and ethanol are 25 s, 236 s, and 574 s at room temperature, respectively. Carbon dioxide, acetone, and ethanol flow into three gas detection channels with the control of a time-sharing conversion switch. Then, carbon dioxide, acetone, and ethanol can be detected accurately by the semiconductor gas sensors. Exhaled acetone can be measured as low as 1 ppm within 5 min without any interference. A highly selective acetone detector based on GC and semiconductor technology has potential in monitoring and detecting diabetes as well as safe driving in a non-invasive way.
引用
收藏
页数:8
相关论文
共 41 条
[1]   Rethinking EBAD: Evolution of smart noninvasive detection of diabetes [J].
Afreen, Sadia ;
Zhu, Jun-Jie .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 118 :477-487
[2]   MEMS-based semi-packed gas chromatography columns [J].
Ali, Syed ;
Ashraf-Khorassani, Mehdi ;
Taylor, Larry T. ;
Agah, Masoud .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01) :309-315
[3]   Advances in chemiresistive sensors for acetone gas detection [J].
Baharuddin, Aainaa Aqilah ;
Ang, Bee Chin ;
Haseeb, A. S. M. A. ;
Wong, Yung Cheng ;
Wong, Yew Hoong .
MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2019, 103
[4]   Selective NO2 sensor based on Bi2O3 branched SnO2 nanowires [J].
Bang, Jae Hoon ;
Choi, Myung Sik ;
Mirzaei, Ali ;
Kwon, Yong Jung ;
Kim, Sang Sub ;
Kim, Tae Whan ;
Kim, Hyoun Woo .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 274 :356-369
[5]  
Bratu AM, 2011, J OPTOELECTRON ADV M, V13, P1045
[6]   The "Metabolic biomarkers of frailty in older people with type 2 diabetes mellitus" (MetaboFrail) study: Rationale, design and methods [J].
Calvani, Riccardo ;
Rodriguez-Manas, Leocadio ;
Picca, Anna ;
Marini, Federico ;
Biancolillo, Alessandra ;
Laosa, Olga ;
Pedraza, Laura ;
Gervasoni, Jacopo ;
Primiano, Aniello ;
Miccheli, Alfredo ;
Bourdel-Marchasson, Isabelle ;
Regueme, Sophie C. ;
Bernabei, Roberto ;
Marzetti, Emanuele ;
Sinclair, Alan J. ;
Gambassi, Giovanni .
EXPERIMENTAL GERONTOLOGY, 2020, 129
[7]  
Calvin Giddings J, 1966, SCIENCE, V152
[8]  
Consortium TL, 2017, ERS INT C
[9]   Assessment, origin, and implementation of breath volatile cancer markers [J].
Haick, Hossam ;
Broza, Yoav Y. ;
Mochalski, Pawel ;
Ruzsanyi, Vera ;
Amann, Anton .
CHEMICAL SOCIETY REVIEWS, 2014, 43 (05) :1423-1449