A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected Inverter

被引:402
作者
Shen, Guoqiao [1 ]
Zhu, Xuancai [1 ]
Zhang, Jun [1 ]
Xu, Dehong [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金; 高等学校博士学科点专项科研基金;
关键词
Current control; harmonic distortion; inverters; LCL filter; 3-PHASE ACTIVE RECTIFIER; PWM CONVERTERS; MODEL; GENERATION; DESIGN;
D O I
10.1109/TIE.2010.2040552
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
For a grid-connected converter with an LCL filter, the harmonic compensators of a proportional-resonant (PR) controller are usually limited to several low-order current harmonics due to system instability when the compensated frequency is out of the bandwidth of the system control loop. In this paper, a new current feedback method for PR current control is proposed. The weighted average value of the currents flowing through the two inductors of the LCL filter is used as the feedback to the current PR regulator. Consequently, the control system with the LCL filter is degraded from a third-order function to a first-order one. A large proportional control-loop gain can be chosen to obtain a wide control-loop bandwidth, and the system can be optimized easily for minimum current harmonic distortions, as well as system stability. The inverter system with the proposed controller is investigated and compared with those using traditional control methods. Experimental results on a 5-kW fuel-cell inverter are provided, and the new current control strategy has been verified.
引用
收藏
页码:2033 / 2041
页数:9
相关论文
共 20 条
  • [1] Interfacing renewable energy sources to the utility grid using a three-level inverter
    Alepuz, Salvador
    Busquets-Monge, Sergio
    Bordonau, Josep
    Gago, Javier
    Gonzalez, David
    Balcells, Josep
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1504 - 1511
  • [2] Implementation and test of an online embedded grid impedance estimation technique for PV inverters
    Asiminoaei, L
    Teodorescu, R
    Blaabjerg, F
    Borup, U
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (04) : 1136 - 1144
  • [3] Active Damping for Three-Phase PWM Rectifiers With High-Order Line-Side Filters
    Bierhoff, Michael H.
    Fuchs, Friedrich Wilhelm
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) : 371 - 379
  • [4] Overview of control and grid synchronization for distributed power generation systems
    Blaabjerg, Frede
    Teodorescu, Remus
    Liserre, Marco
    Timbus, Adrian V.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1398 - 1409
  • [5] A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter
    Blasko, V
    Kaura, V
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) : 542 - 550
  • [6] Model-based generation of low distortion currents in grid-coupled PWM-Inverters using an LCL output filter
    Bolsens, Bruno
    De Brabandere, Karel
    Van den Keybus, Jeroen
    Driesen, Johan
    Belmans, Ronnie
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (04) : 1032 - 1040
  • [7] Comparison of current control techniques for active filter applications
    Buso, S
    Malesani, L
    Mattavelli, P
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (05) : 722 - 729
  • [8] Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With LCL Filters
    Dannehl, Joerg
    Wessels, Christian
    Fuchs, Friedrich Wilhelm
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) : 380 - 388
  • [9] Fukuda S, 2001, IEEE T IND APPL, V37, P888, DOI 10.1109/28.924772
  • [10] Current control techniques for three-phase voltage-source PWM converters: A survey
    Kazmierkowski, MP
    Malesani, L
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (05) : 691 - 703