Neutron radiography using neutron imaging plate

被引:13
作者
Chankow, Nares [1 ]
Punnachaiya, Suvit [1 ]
Wonglee, Sarinrat [2 ]
机构
[1] Chulalongkorn Univ, Bangkok 10330, Thailand
[2] Thailand Inst Nucl Technol, Bangkok 10900, Thailand
关键词
Neutron imaging plate; Neutron radiography; Nondestructive testing; Photostimulated luminescence;
D O I
10.1016/j.apradiso.2009.09.021
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The aims of this research are to study properties of a neutron imaging plate (NIP) and to test it for use in nondestructive testing (NDT) of materials. The experiments were carried out by using a BAS-ND 2040 Fuji NIP and a neutron beam from the Thai Research Reactor TRR-1/M1. The neutron intensity and Cd ratio at the specimen position were approximately 9 x 10(5) ns/cm(2)s and 100 respectively. It was found that the photostimulated luminescence (PSL) readout of the imaging plate was directly proportional to the exposure time and approximately 40 times faster than the conventional NR using Gd converter screen/X-ray film technique. The sensitivities of the imaging plate to slow neutron and to Ir-192 gamma-rays were found to be approximately 4.2 x 10(-3) PSL/mm(2) per neutron and 6.7 x 10(-5) PSL/mm(2) per gamma-ray photon respectively. Finally, some specimens containing light elements were selected to be radiographed with neutrons using the NIP and the Gd converter screen/X-ray film technique. The image quality obtained from the two recording media was found to be comparable. Crown Copyright (C) 2009 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:662 / 664
页数:3
相关论文
共 6 条
[1]  
Domanus J.C., 1992, PRACTICAL NEUTRON RA
[2]  
GARRETT DA, 1977, ATOMIC ENERGY REV, V15
[3]   Gadolinium sheet converter for neutron radiography [J].
Lima, C. T. S. ;
Crispim, V. R. ;
Santos, W. M. S. .
APPLIED RADIATION AND ISOTOPES, 2007, 65 (12) :1381-1385
[4]  
Miyahara J., 1989, CHEM TODAY, V10, P29
[5]  
NGERNVIJIT N, 2003, J NUCL SOC THAILAND, V4
[6]  
von der Hardt P., 1981, NEUTRON RADIOGRAPHY