Evaluation of a von Willebrand factor three test panel and chemiluminescent-based assay system for identification of, and therapy monitoring in, von Willebrand disease

被引:42
作者
Favaloro, Emmanuel J.
Mohammed, Soma
机构
[1] Westmead Hosp, Dept Haematol, Sydney Ctr Thrombosis, ICPMR,Pathol West,NSW Hlth Pathol, Westmead, NSW 2145, Australia
[2] Westmead Hosp, Dept Haematol, Sydney Ctr Haemostasis, ICPMR,Pathol West,NSW Hlth Pathol, Westmead, NSW 2145, Australia
关键词
von Willebrand disease; Diagnosis; VWD; von Willebrand factor; VWF; Laboratory testing; Collagen binding; Ristocetin cofactor; AcuStar; Chemiluminescence; RISTOCETIN COFACTOR ACTIVITY; AUTOMATED ASSAYS; FACTOR ANTIGEN; DIAGNOSIS; MANAGEMENT; ERRORS;
D O I
10.1016/j.thromres.2015.12.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
von Willebrand disease (VWD) is reportedly the most common bleeding disorder and arises from deficiency and/or defects of von Willebrand factor (VWF). Laboratory diagnosis and typing of VWD has important management implications and requires a wide range of tests, including VWF antigen (VWF: Ag) and various activities, involving differential identification of qualitative vs quantitative VWF defects. We have assessed a new hemostasis instrument, the chemiluminescent assay based ACL AcuStar T, and an associated HemosIL AcuStar three test panel comprising VWF: Ag, VWF ristocetin cofactor (VWF:RCo) and VWF collagen binding (VWF: CB) (Instrumentation Laboratory, Bedford, Ma. USA) for ability to identify VWD, to help provisionally type VWD, and for potential use in therapy monitoring. This test system was compared to previously evaluated and validated test systems including VWF: RCo on CS-5100 and BCS analyzers, the new Siemens INNOVANCE assay (VWF Ac) on CS-5100, and VWF: Ag and VWF: CB assays performed by automated ELISA. We employed a large total sample test set (n = 535) comprising plasma and platelet-lysate samples from individuals with and without VWD, some on treatment, normal plasmas, and normal and pathological controls. We also evaluated desmopressin (DDAVP) responsiveness, plus differential sensitivity to reduction in high molecular weight (HMW) VWF. The chemiluminescent test panel (VWF: Ag, VWF: RCo, VWF: CB) showed good comparability to similar assays performed by alternate methods, and broadly similar data for identification of VWD, provisional VWD type identification, DDAVP and VWD therapy, and HMW VWF sensitivity, although some notable differences were evident. The chemiluminescent system showed best low level VWF sensitivity, and lowest inter-assay variability, compared to all other systems. In conclusion, we have validated the ACL AcuStar and the chemiluminescent HemosIL AcuStar VWF test panel for use in VWD diagnostics, and have identified some favorable characteristics that may improve the future diagnosis of VWD. Crown Copyright (C) 2015 Published by Elsevier Ltd.
引用
收藏
页码:202 / 211
页数:10
相关论文
共 32 条
[1]   Diagnosing von Willebrand disease: A large reference laboratory's perspective [J].
Adcock, Dorothy M. ;
Bethel, Melissa ;
Valcour, Andre .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2006, 32 (05) :472-479
[2]   Implications for collagen I chain registry from the structure of the collagen von Willebrand factor A3 domain complex [J].
Brondijk, T. Harma C. ;
Bihan, Dominique ;
Farndale, Richard W. ;
Huizinga, Eric G. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (14) :5253-5258
[3]   Laboratory testing for von Willebrand Disease: Contribution of multimer analysis to diagnosis and classification [J].
Budde, Ulrich ;
Pieconka, Antje ;
Will, Kirsten ;
Schneppenheim, Reinhard .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2006, 32 (05) :514-521
[4]   Comparison of a new chemiluminescent immunoassay for von Willebrand factor activity with the ristocetin cofactor-induced platelet agglutination method [J].
Cabrera, N. ;
Moret, A. ;
Caunedo, P. ;
Cid, A. R. ;
Vila, V. ;
Espana, F. ;
Aznar, J. A. .
HAEMOPHILIA, 2013, 19 (06) :920-925
[5]   Changes of von Willebrand Factor during Pregnancy in Women with and without von Willebrand Disease [J].
Castaman, Giancarlo .
MEDITERRANEAN JOURNAL OF HEMATOLOGY AND INFECTIOUS DISEASES, 2013, 5 (01)
[6]   Diagnosis of inherited von Willebrand disease: comparison of two methodologies and analysis of the discrepancies [J].
Costa-Pinto, J. ;
Perez-Rodriguez, A. ;
Gomez-del-Castillo, M. Del C. ;
Loures, E. ;
Rodriguez-Trillo, A. ;
Batlle, J. ;
Lopez-Fernandez, M. F. .
HAEMOPHILIA, 2014, 20 (04) :559-567
[7]   Performance of two new automated assays for measuring von Willebrand activity: HemosIL Acu Star and Innovance [J].
de Maistre, Emmanuel ;
Volot, Fabienne ;
Mourey, Guillaume ;
Aho, Ludwig S. ;
Ternisien, Catherine ;
Briquel, Marie-Elisabeth ;
Bertrand, Marie-Anne ;
Tardy, Brigitte ;
Frotscher, Birgit ;
Nguyen, Philippe ;
Dumont, Laure ;
Vandroux, David ;
Hezard, Nathalie ;
Trossaert, Marc .
THROMBOSIS AND HAEMOSTASIS, 2014, 112 (04) :825-830
[8]   Clinical efficacy and safety of the factor VIII/von Willebrand factor concentrate BIOSTATE® in patients with von Willebrand's disease: a prospective multi-centre study [J].
Dunkley, S. ;
Baker, R. I. ;
Pidcock, M. ;
Price, J. ;
Seldon, M. ;
Smith, M. ;
Street, A. ;
Maher, D. ;
Barrese, G. ;
Stone, C. ;
Lloyd, J. .
HAEMOPHILIA, 2010, 16 (04) :615-624
[9]   von Willebrand disease and platelet disorders [J].
Favaloro, E. J. ;
Bodo, I. ;
Israels, S. J. ;
Brown, S. A. .
HAEMOPHILIA, 2014, 20 :59-64
[10]   Differential sensitivity of von Willebrand factor (VWF) 'activity' assays to large and small VWF molecular weight forms: a cross-laboratory study comparing ristocetin cofactor, collagen-binding and mAb-based assays [J].
Favaloro, E. J. ;
Bonar, R. ;
Chapman, K. ;
Meiring, M. ;
Funk , D. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2012, 10 (06) :1043-1054