Predicting transmitted irradiance through CAD/CAM resin composite crowns in a simulated clinical model

被引:5
作者
Butterhof, Maximilian [1 ]
Ilie, Nicoleta [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Operat Restorat Dent Periodontol & Pedodont, Goethestr 70, D-80336 Munich, Germany
关键词
CAD/CAM; Composite crown; Resin-based composite; Correction model; Light curing; Irradiance; Transmission; LIGHT-CURING UNITS; PATIENT SIMULATOR; CONVERSION; RESTORATION; DENTISTRY; ENERGY; CEMENT;
D O I
10.1016/j.dental.2021.03.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To predict the clinically relevant transmitted irradiance that is available for luting when a CAD/CAM restoration is inserted. The influence of irradiance, exposure distance, light curing unit (LCU) angulation and direction of polymerization is analyzed when curing through crowns of different thicknesses. Methods. Three modern CAD/CAM resin-based composites (RBCs) were used to produce 45 crown-shaped specimens. The distance between fissure and crown base was set at 1.0, 1.5 and 2.0 mm (n = 5). Transmitted irradiance, while using a violet-blue LCU, was measured with a photo-spectrometer. 180 exposure conditions per specimen were investigated by variation in LCU curing mode, angulation, exposure distance and direction. Data was analyzed using univariate ANOVA followed by Tukey HSD (alpha = 0.05) and comparison of 95% confidence intervals. Results. The CAD/CAM-RBC's decadic absorption coefficient ranges from 0.317 mm(-1) to 0.387 mm(-1) and the reflection correcting factor for crowns ranges from 0.305 to 0.337. Transmitted irradiance decreases significantly with increasing exposure distance and decreasing incident irradiance. For tilt angles greater than 10 degrees, transmitted irradiances are significantly reduced (-11% for 20 degrees, -23% for 30 degrees). Significantly lowest transmitted irradiances were measured for vestibular curing direction (up to -15%). Significance. A calculation model can predict the transmitted irradiance through a CAD/CAM restoration in dependence of restoration thickness and radiant emittance. The practitioner can be supported by this model to adapt material choice of dental restoration and adhesive system to the individual situation. Variation in exposure conditions shows negative effect on the transmission of light and should be limited. (C) 2021 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:998 / 1008
页数:11
相关论文
共 29 条
[1]   Degree of conversion and cross-link density within a resin-matrix composite [J].
Al-Zain, Afnan O. ;
Eckert, George J. ;
Lukic, Henry ;
Megremis, Spiro J. ;
Platt, Jeffrey A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (04) :1496-1504
[2]   Degree of conversion and depth of cure of Ivocerin containing photo-polymerized resin luting cement in comparison to conventional luting agents [J].
Alkhudhairy, Fahad ;
AlKheraif, Abdulaziz ;
Naseem, Mustafa ;
Khan, Rawaiz ;
Vohra, Fahim .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2018, 34 (02) :253-259
[3]   Natural Tooth Pontic Using Recent Adhesive Technologies: An Esthetic and Minimally Invasive Prosthetic Solution [J].
Augusti, Davide ;
Augusti, Gabriele ;
Ionescu, Andrei ;
Brambilla, Eugenio ;
Re, Dino .
CASE REPORTS IN DENTISTRY, 2020, 2020
[4]   The effect of restoration thickness and resin cement shade on the color and translucency of a high-translucency monolithic zirconia [J].
Bayindir, Funda ;
Koseoglu, Merve .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01) :149-154
[5]   Mathematical model for assessing true irradiance received by luting materials while curing through modern CAD/CAM resin composites [J].
Butterhof, Maximilian ;
Ilie, Nicoleta .
DENTAL MATERIALS, 2020, 36 (08) :E255-E265
[6]   The role of polymerization in adhesive dentistry [J].
Cadenaro, Milena ;
Maravic, Tatjana ;
Comba, Allegra ;
Mazzoni, Annalisa ;
Fanfoni, Lidia ;
Hilton, Tom ;
Ferracane, Jack ;
Breschi, Lorenzo .
DENTAL MATERIALS, 2019, 35 (01) :E1-E22
[7]   Current aspects on bonding effectiveness and stability in adhesive dentistry [J].
Cardoso, M. V. ;
Neves, A. de Almeida ;
Mine, A. ;
Coutinho, E. ;
Van Landuyt, K. ;
De Munck, J. ;
Van Meerbeek, B. .
AUSTRALIAN DENTAL JOURNAL, 2011, 56 :31-44
[8]   Patterns and properties of polarized light in air and water [J].
Cronin, Thomas W. ;
Marshall, Justin .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2011, 366 (1565) :619-626
[9]   Impact of filler size and distribution on roughness and wear of composite resin after simulated toothbrushing [J].
de Oliveira, Gabriela Ulian ;
Lia Mondelli, Rafael Francisco ;
Rodrigues, Marcela Charantola ;
Franco, Eduardo Batista ;
Ishikiriama, Sergio Kiyoshi ;
Wang, Linda .
JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (05) :510-516
[10]  
Federlin M, 2013, J DENT EDUC, V77, P764