The diagnostic utility of dual phase Tc-99m sestamibi parathyroid imaging

被引:25
|
作者
Klieger, P [1 ]
O'Mara, R [1 ]
机构
[1] Univ Rochester, Med Ctr, Div Nucl Med, Rochester, NY 14642 USA
关键词
hyperparathyroidism; intraoperative probe; parathyroid adenoma; Tc-99m-sestamibi imaging;
D O I
10.1097/00003072-199804000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Primary hyperparathyroidism is a disease of uncertain etiology that results from hypersecretion of parathyroid hormone (PTH) by the parathyroid gland. In most institutions, the preferred imaging protocol utilizes a dual-phase technique with Tc-99m sestamibi which is reported to be more sensitive than earlier protocols involving TI-201 with Tc-99m pertechnetate subtraction. The purpose of this study is to evaluate the accuracy and clinical utility of Tc-99m sestamibi dual-phase scintigraphy for localizing hyperfunctioning parathyroid tissue. Materials and Methods: We retrospectively reviewed thirty-nine consecutive hyperparathyroid patients who received a dual-phase Tc-99m sestamibi parathyroid scan. Thirty-seven of the subjects subsequently underwent a bilateral neck exploration and parathyroidectomy. Each scan interpretation was then correlated with the histopathologic diagnosis and the patients' postsurgical clinical course. Results: The sestamibi dual-phase imaging protocol correctly localized 21 of 25 parathyroid adenomas and identified 8 out of 10 cases of hyperplasia. Our overall sensitivity and specificity were 83% acid 75%, respectively. In addition, four of the adenomas were successfully localized intraoperatively using a gamma probe. Conclusion: Parathyroid imaging with sestamibi appears to be superior to TI-201/Tc-99m pertechnetate subfraction based on the reported results of both techniques at various institutions. Dual-phase sestamibi imaging appears to be useful and cost-effective for presurgical Localization of hyperfunctioning parathyroid tissue. In addition, sestamibi imaging in conjunction with an intraoperative probe is a very promising technique that has the potential to provide both localization information of a suspected parathyroid adenoma and to facilitate its surgical removal by reducing operation time.
引用
收藏
页码:208 / 211
页数:4
相关论文
共 50 条
  • [21] Tc-99m sestamibi scintigraphy of double parathyroid adenoma
    Nguyen, BD
    Chin, BB
    LugoOlivieri, CH
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (12) : 856 - 856
  • [22] Parathyroid imaging with Tc-99m-sestamibi
    Gordon, BM
    Gordon, L
    Hoang, K
    Spicer, KM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (06) : 1563 - 1568
  • [23] Parathyroid imaging with Tc-99m sestamibi planar and SPECT scintigraphy - Invited commentary
    Kotlyarov, EV
    RADIOGRAPHICS, 1999, 19 (03) : 615 - 616
  • [24] Localization of parathyroid glands in hemodialysis patients using Tc-99m sestamibi imaging
    Ishibashi, M
    Nishida, H
    Okuda, S
    Suekane, S
    Hayabuchi, N
    NEPHRON, 1998, 78 (01): : 48 - 53
  • [25] TC-99M TETROFOSMIN - A NEW DIAGNOSTIC TRACER FOR PARATHYROID IMAGING
    ISHIBASHI, M
    NISHIDA, H
    KUMABE, T
    MORITA, S
    MATOBA, F
    NOMURA, G
    HAYABUCHI, N
    CLINICAL NUCLEAR MEDICINE, 1995, 20 (10) : 902 - 905
  • [26] PARATHYROID SCINTIGRAPHY - TC-99M PERTECHNETATE (TC), THALLIUM-99M SESTAMIBI(S)
    PALESTRO, CJ
    MOSKOWITZ, GW
    AFRIYIE, M
    CHINOL, M
    SCHIFF, RG
    MAGUIRE, WM
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P166 - P166
  • [27] Tc-99m tetrofosmin in parathyroid imaging
    Demetriadou, R
    Pierides, A
    Tziakouri, C
    Demetriou, K
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1152 - 1152
  • [28] Four ectopic parathyroid glands detected with Tc-99m sestamibi
    Sutter, CW
    Shelton, DK
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (02) : 120 - 121
  • [29] A retroesophageal parathyroid adenoma detected with Tc-99m sestamibi and MRI
    Zentner, J
    Vogt, H
    Heidenreich, P
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (12) : 998 - 999
  • [30] Unsuspected lymphoma detected on Tc-99m sestamibi parathyroid scan
    Thomas, RJ
    Joyce, JM
    Myers, DT
    Lotfi, K
    Organist, M
    CLINICAL NUCLEAR MEDICINE, 2000, 25 (09) : 716 - 718