Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging

被引:37
作者
Bliznakova, K. [1 ]
Speller, R. [2 ]
Horrocks, J. [3 ]
Liaparinos, P. [4 ]
Kolitsi, Z. [1 ]
Pallikarakis, N. [1 ]
机构
[1] Univ Patras, Fac Med, Dept Med Phys, Patras 26500, Greece
[2] UCL, Dept Med Phys & Bioengn, London, England
[3] St Bartholomews Hosp, Clin Phys Grp, London, England
[4] Technol Educ Inst Athens, Dept Med Instruments Technol, Athens, Greece
关键词
X-ray imaging simulation; Synchrotron radiation; Breast phantoms; Experimental verification; DETECTIVE QUANTUM EFFICIENCY; PHOSPHOR SCREENS; SYNCHROTRON-RADIATION; NOISE; MAMMOGRAPHY; PERFORMANCE; MODEL; RADIOLOGY; SYSTEMS; CT;
D O I
10.1016/j.compbiomed.2009.11.017
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Computer models and simulations of X-ray imaging systems are becoming a very precious tool during the development and evaluation of new X-ray imaging techniques. To provide, however, a faithful simulation of a system, all components must be accurately modelled and tested, followed by verification through experimental measurements. This paper presents a validation study of the XRayImagingSimulator, an in-house developed X-ray imaging simulator, which is extensively used as a basic tool in carrying out complex breast imaging simulations. The approach followed compares results obtained via an experimental setup for breast phantom (CIRS 011A) imaging, using synchrotron radiation (SYRMEP beamline at ELETTRA), with those from its simulated setup under the same conditions. The study demonstrated a very good agreement between experimental and simulated images compared both in terms of subjective and objective criteria. The combination of the XRayImagingSimulator with our BreastSimulator provides a powerful tool for in silico testing of new X-ray breast imaging approaches. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 36 条
[1]   Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA [J].
Abrami, A ;
Arfelli, F ;
Barroso, RC ;
Bergamaschi, A ;
Billé, F ;
Bregant, P ;
Brizzi, F ;
Casarin, K ;
Castelli, E ;
Chenda, V ;
Palma, LD ;
Dreossi, D ;
Fava, A ;
Longo, R ;
Mancini, L ;
Menk, RH ;
Montanari, F ;
Olivo, A ;
Pani, S ;
Pillon, A ;
Quai, E ;
Kaiser, SR ;
Rigon, L ;
Rokvic, T ;
Tonutti, M ;
Tromba, G ;
Vaseotto, A ;
Venanzi, C ;
Zanconati, F ;
Zanetti, A ;
Zanini, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) :221-227
[3]   Mammogram synthesis using a 3D simulation. 1. Breast tissue model and image acquisition simulation [J].
Bakic, PR ;
Albert, M ;
Brzakovic, D ;
Maidment, ADA .
MEDICAL PHYSICS, 2002, 29 (09) :2131-2139
[4]   Dual-energy mammography: simulation studies [J].
Bliznakova, K. ;
Kolitsi, Z. ;
Pallikarakis, N. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18) :4497-4515
[5]   A three-dimensional breast software phantom for mammography simulation [J].
Bliznakova, K ;
Bliznakov, Z ;
Bravou, V ;
Kolitsi, Z ;
Pallikarakis, N .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (22) :3699-3719
[6]  
Bliznakova K, 2005, IFMBE P EMBEC PRAG, P1402
[7]   Scatter/primary in mammography: Comprehensive results [J].
Boone, JM ;
Lindfors, KK ;
Cooper, VN ;
Seibert, JA .
MEDICAL PHYSICS, 2000, 27 (10) :2408-2416
[8]   Dedicated breast CT: Radiation dose and image quality evaluation [J].
Boone, JM ;
Nelson, TR ;
Lindfors, KK ;
Seibert, JA .
RADIOLOGY, 2001, 221 (03) :657-667
[9]   X-ray characterization of breast phantom materials [J].
Byng, JW ;
Mainprize, JG ;
Yaffe, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1367-1377
[10]   Cone-beam volume CT breast imaging: Feasibility study [J].
Chen, B ;
Ning, R .
MEDICAL PHYSICS, 2002, 29 (05) :755-770