The Effect of Er:YAG Laser on a Shear Bond Strength Value of Orthodontic Brackets to Enamel-A Preliminary Study

被引:14
作者
Kiryk, Jan [1 ]
Matys, Jacek [1 ]
Nikodem, Anna [2 ]
Burzynska, Karolina [2 ]
Grzech-Lesniak, Kinga [1 ,3 ]
Dominiak, Marzena [1 ]
Dobrzynski, Maciej [4 ]
机构
[1] Wroclaw Med Univ, Oral Surg Dept, Krakowska St 26, PL-50425 Wroclaw, Poland
[2] Wroclaw Univ Sci & Technol, Dept Mech Mat & Biomed Engn, Wybrzeze Wyspianskiego St 27, PL-50370 Wroclaw, Poland
[3] Virginia Commonwealth Univ, Dept Periodont, Sch Dent, 12th St, Richmond, VA 23298 USA
[4] Wroclaw Med Univ, Dept Pediat Dent & Preclin Dent, Krakowska St 26, PL-50425 Wroclaw, Poland
关键词
microtomography; orthodontic brackets; roughness; shear strength; surface conditioning; ER-YAG-LASER; AIR-ABRASION; ACID; IRRADIATION; MICROLEAKAGE; TEMPERATURE;
D O I
10.3390/ma14092093
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We sought to evaluate the effects of Er:YAG laser (LightTouch, LightInstruments, Israel) conditioning on enamel roughness and shear bond strength of orthodontic brackets on enamel. Eighteen human molars (n = 9) and premolars (n = 9), were divided into 3 groups depending on the enamel conditioning method; Er:YAG laser (G1, n = 6), conventional etching with 37% orthophosphoric acid (G2, n = 6), Er:YAG laser combined with conventional etching (G3, n = 6). Er:YAG laser parameters were as follows: energy: 100 mJ, frequency: 10 Hz, exposure time: 10 s, applicator diameter: 600 mu m, fluence: 35.37 J/cm(2), distance: 1 mm away from a tooth, cooling: 80%. An MTS 858 MiniBionix(R) machine was used to determine the shear bond strength (MTS System, Eden Prairie, MN, USA). The enamel structure was assessed using X-ray microtomography (SkyScan 1172, Bruker, Kontich, Belgium). The highest values of shear bond strength were obtained in the G3 group (9.23 +/- 2.38 MPa) and the lowest values in the G2 group (6.44 +/- 2.11 MPa) (p < 0.05). A significant change in the enamel surface was noted after applying laser, reaching up to 9% of enamel thickness, which was not observed in the etched samples. Moreover, the Er:YAG laser-irradiated enamel surface was characterized by the greatest roughness. The combined use of an Er:YAG laser with a conventional etching improves the adhesion of composite materials to the tooth.
引用
收藏
页数:11
相关论文
共 36 条
[11]  
Ferrari M, 1997, AM J DENT, V10, P66
[12]   Low-Level Laser Therapy with a 635 nm Diode Laser Affects Orthodontic Mini-Implants Stability: A Randomized Clinical Split-Mouth Trial [J].
Flieger, Rafal ;
Gedrange, Tomasz ;
Grzech-Lesniak, Kinga ;
Dominiak, Marzena ;
Matys, Jacek .
JOURNAL OF CLINICAL MEDICINE, 2020, 9 (01)
[13]   Microleakage of Sealants after Phosphoric Acid, Er: YAG Laser and Air Abrasion Enamel Conditioning: Systematic Review and Meta-Analysis [J].
Fumes, Ana Caroline ;
Longo, Daniele Lucca ;
De Rossi, Andiara ;
da Silva Fidalgo, Tatiana Kelly ;
Garcia de Paula e Silva, Francisco Wanderley ;
Borsatto, Maria Cristina ;
Kuchler, Erika Calvano .
JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2017, 41 (03) :167-172
[14]   The influence of Er:YAG laser conditioning versus self-etching adhesives with acid etching on the shear bond strength of orthodontic brackets [J].
Gokcelik, Aylin ;
Ozel, Yonca ;
Ozel, Emre ;
Arhun, Neslihan ;
Attar, Nuray ;
Firatli, Sonmez ;
Firatli, Erhan .
PHOTOMEDICINE AND LASER SURGERY, 2007, 25 (06) :508-512
[15]   Effects of Nd:YAG laser irradiation on the growth of Candida albicans and Streptococcus mutans: in vitro study [J].
Grzech-Lesniak, Kinga ;
Nowicka, Joanna ;
Pajaczkowska, Magdalena ;
Matys, Jacek ;
Szymonowicz, Maria ;
Kuropka, Piotr ;
Rybak, Zbigniew ;
Dobrzynski, Maciej ;
Dominiak, Marzena .
LASERS IN MEDICAL SCIENCE, 2019, 34 (01) :129-137
[16]   Er:YAG Laser for Metal and Ceramic Bracket Debonding: An In Vitro Study on Intrapulpal Temperature, SEM, and EDS Analysis [J].
Grzech-Lesniak, Kinga ;
Matys, Jacek ;
Zmuda-Stawowiak, Dorota ;
Mroczka, Krzysztof ;
Dominiak, Marzena ;
Brugnera Junior, Aldo ;
Gruber, Reinhard ;
Romanos, Georgios E. ;
Sculean, Anton .
PHOTOMEDICINE AND LASER SURGERY, 2018, 36 (11) :595-600
[17]   Correlation of resin viscosity and monomer conversion to filler particle size in dental composites [J].
Habib, Eric ;
Wang, Ruili ;
Zhu, X. X. .
DENTAL MATERIALS, 2018, 34 (10) :1501-1508
[18]   Atomic analysis and knoop hardness measurement of the cavity floor prepared by Er,Cr:YSGG laser irradiation in vitro [J].
Hossain, M ;
Nakamura, Y ;
Tamaki, Y ;
Yamada, Y ;
Murakami, Y ;
Matsumoto, K .
JOURNAL OF ORAL REHABILITATION, 2003, 30 (05) :515-521
[19]  
Hosseini M H, 2012, J Dent (Tehran), V9, P20
[20]  
Karol G., 1972, CWICZENIA LAB WYTRZY