The Effect of Er:YAG Laser on a Shear Bond Strength Value of Orthodontic Brackets to Enamel-A Preliminary Study

被引:14
作者
Kiryk, Jan [1 ]
Matys, Jacek [1 ]
Nikodem, Anna [2 ]
Burzynska, Karolina [2 ]
Grzech-Lesniak, Kinga [1 ,3 ]
Dominiak, Marzena [1 ]
Dobrzynski, Maciej [4 ]
机构
[1] Wroclaw Med Univ, Oral Surg Dept, Krakowska St 26, PL-50425 Wroclaw, Poland
[2] Wroclaw Univ Sci & Technol, Dept Mech Mat & Biomed Engn, Wybrzeze Wyspianskiego St 27, PL-50370 Wroclaw, Poland
[3] Virginia Commonwealth Univ, Dept Periodont, Sch Dent, 12th St, Richmond, VA 23298 USA
[4] Wroclaw Med Univ, Dept Pediat Dent & Preclin Dent, Krakowska St 26, PL-50425 Wroclaw, Poland
关键词
microtomography; orthodontic brackets; roughness; shear strength; surface conditioning; ER-YAG-LASER; AIR-ABRASION; ACID; IRRADIATION; MICROLEAKAGE; TEMPERATURE;
D O I
10.3390/ma14092093
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We sought to evaluate the effects of Er:YAG laser (LightTouch, LightInstruments, Israel) conditioning on enamel roughness and shear bond strength of orthodontic brackets on enamel. Eighteen human molars (n = 9) and premolars (n = 9), were divided into 3 groups depending on the enamel conditioning method; Er:YAG laser (G1, n = 6), conventional etching with 37% orthophosphoric acid (G2, n = 6), Er:YAG laser combined with conventional etching (G3, n = 6). Er:YAG laser parameters were as follows: energy: 100 mJ, frequency: 10 Hz, exposure time: 10 s, applicator diameter: 600 mu m, fluence: 35.37 J/cm(2), distance: 1 mm away from a tooth, cooling: 80%. An MTS 858 MiniBionix(R) machine was used to determine the shear bond strength (MTS System, Eden Prairie, MN, USA). The enamel structure was assessed using X-ray microtomography (SkyScan 1172, Bruker, Kontich, Belgium). The highest values of shear bond strength were obtained in the G3 group (9.23 +/- 2.38 MPa) and the lowest values in the G2 group (6.44 +/- 2.11 MPa) (p < 0.05). A significant change in the enamel surface was noted after applying laser, reaching up to 9% of enamel thickness, which was not observed in the etched samples. Moreover, the Er:YAG laser-irradiated enamel surface was characterized by the greatest roughness. The combined use of an Er:YAG laser with a conventional etching improves the adhesion of composite materials to the tooth.
引用
收藏
页数:11
相关论文
共 36 条
[1]  
Akhoundi Mohammad Sadegh Ahmad, 2017, J Dent (Tehran), V14, P144
[2]   Comparison of sandblasting, laser irradiation, and conventional acid etching for orthodontic bonding of molar tubes [J].
Berk, Nuket ;
Basaran, Guevenc ;
Oezer, Toerun .
EUROPEAN JOURNAL OF ORTHODONTICS, 2008, 30 (02) :183-189
[3]  
Bishara SE, 2007, ANGLE ORTHOD, V77, P337, DOI 10.2319/0003-3219(2007)077[0337:SBSCOT]2.0.CO
[4]  
2
[5]  
Borges Alessandra Buhler, 2019, F1000Res, V8, P1743, DOI 10.12688/f1000research.20523.1
[6]   Microleakage of a resin sealant after acid-etching, Er:YAG laser irradiation and air-abrasion of pits and fissures [J].
Borsatto, MC ;
Corona, SAM ;
Palma, RG ;
Ramos, RP ;
Pécora, JD .
JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2001, 19 (02) :83-87
[7]   Bonding Interaction and Shrinkage Stress of Low-viscosity Bulk Fill Resin Composites With High-viscosity Bulk Fill or Conventional Resin Composites [J].
Cerda-Rizo, E. R. ;
Rodrigues, M. de Paula ;
Vilela, A. B. F. ;
Braga, S. S. L. ;
Oliveira, L. R. S. ;
Garcia-Silva, T. C. ;
Soares, C. J. .
OPERATIVE DENTISTRY, 2019, 44 (06) :625-636
[8]   Influence of Er:YAG laser irradiation distance on the bond strength of a restorative system to enamel [J].
Chimello-Sousa, DT ;
de Souza, AE ;
Chinelatti, MA ;
Pécora, JD ;
Palma-Dibb, RG ;
Corona, SAM .
JOURNAL OF DENTISTRY, 2006, 34 (03) :245-251
[9]   Evaluation of Self-Etching Adhesive and Er:YAG Laser Conditioning on the Shear Bond Strength of Orthodontic Brackets [J].
Contreras-Bulnes, Rosalia ;
Scougall-Vilchis, Rogelio J. ;
Rodriguez-Vilchis, Laura E. ;
Centeno-Pedraza, Claudia ;
Olea-Mejia, Oscar F. ;
Alcantara-Galena, Maria del Carmen Z. .
SCIENTIFIC WORLD JOURNAL, 2013,
[10]  
Dehghani Mahboobe, 2014, J Clin Exp Dent, V6, pe379, DOI 10.4317/jced.51613