In vitro Results of Scanning Technique on Assessing Cement Thickness and Interfacial Nanoleakage of Luted CAD/CAM-Fabricated Fiber Posts

被引:7
作者
Vaddamanu, Sunil Kumar [1 ]
Vyas, Rajesh [1 ]
Bavabeedu, Shashit Shetty [2 ]
Arora, Suraj [2 ]
Badiyani, Bhumika Kamal [3 ]
Kumar, Amit [3 ]
机构
[1] King Khalid Univ, Coll Appl Med Sci, Dept Dent Technol, Abha, Saudi Arabia
[2] King Khalid Univ, Coll Dent, Dept Restorat Dent Sci, Abha, Saudi Arabia
[3] Dept Publ Hlth Dent, Mumbai, Maharashtra, India
关键词
CAD; CAM; cement thickness; fiber post; nanoleakage; post retention; scanning techniques; CORE;
D O I
10.4103/jpbs.JPBS_761_20
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Fiber posts are broadly used due to their good esthetics and elasticity close to that of dentin, which allows for uniform stress distribution within a root and lowers the possibility of nonrestorable root fractures. Aim and Objectives: The study assessed the layer of cement thickness and interfacial nanoleakage of luted fiber posts which were fabricated with CAD/CAM technology following direct scanning of the post space (DS) method, scanning of a polyether impression of the post space (IS), and scanning of a plaster model of the post space (MS). Methodology: Ninety premolars were chosen randomly and were assigned to three groups according to the scanning technique. Posts were computer designed and milled from experimental fiber-reinforced composite blocks. Results: The mean and standard deviation values of cement thickness, respectively, were: DS 172 +/- 39 = m; IS 199 +/- 55 = m, and MS MPa 272 +/- 81 = m. The fiber posts fabricated following DS technique demonstrated superior performance compared to posts fabricated upon IS and MS, in terms of the post retention. The cement thickness did not differ between DS and IS, whereas in MS group, the cement layer was significantly thicker than in the remaining two groups. The scanning technique did not influence the sealing ability, as all groups showed comparable nanoleakage. Conclusion: Fiber posts fabricated following DS technique demonstrated superior performance. Furthermore, scanning technique did not influence the sealing ability, as all groups showed comparable nanoleakage.
引用
收藏
页码:676 / 678
页数:3
相关论文
共 13 条
[1]   Retentive strength and sealing ability of new self-adhesive resin cements in fiber post luting [J].
Cantoro, Amerigo ;
Goracci, Cecilia ;
Vichi, Alessandro ;
Mazzoni, Annalisa ;
Fadda, Giovanni Maria ;
Ferrari, Marco .
DENTAL MATERIALS, 2011, 27 (10) :E197-E204
[2]   Finite element analysis of stress distribution in four different endodontic post systems in a model canine [J].
Chen, Aijie ;
Feng, Xiaoli ;
Zhang, Yanli ;
Liu, Ruoyu ;
Shao, Longquan .
BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 :S629-S635
[3]   Finite element analysis to study the effects of using CAD/CAM glass-fiber post system in a severely damaged anterior tooth [J].
Chen, Aijie ;
Feng, Xiaoli ;
Zhang, Yanli ;
Liu, Ruoyu ;
Shao, Longquan .
BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 :S519-S525
[4]   A Novel Computer-Aided Method to Fabricate a Custom One-Piece Glass Fiber Dowel-and-Core Based on Digitized Impression and Crown Preparation Data [J].
Chen, Zhiyu ;
Li, Ya ;
Deng, Xuliang ;
Wang, Xinzhi .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (04) :276-283
[5]   Accuracy of digital models obtained by direct and indirect data capturing [J].
Gueth, Jan-Frederik ;
Keul, Christine ;
Stimmelmayr, Michael ;
Beuer, Florian ;
Edelhoff, Daniel .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (04) :1201-1208
[6]  
Kurbad Andreas, 2011, Int J Comput Dent, V14, P59
[8]   FABRICATING A FIBER-REINFORCED POST AND ZIRCONIA CORE WITH CAD/CAM TECHNOLOGY [J].
Lee, Ju-Hyoung ;
Sohn, Dong-Seok ;
Lee, Cheong-Hee .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03) :683-685
[9]   USE OF A CAD/CAM-FABRICATED GLASS FIBER POST AND CORE TO RESTORE FRACTURED ANTERIOR TEETH: A CLINICAL REPORT [J].
Liu, Peng ;
Deng, Xu-Liang ;
Wang, Xin-Zhi .
JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (06) :330-333
[10]   A new method for the computer-aided evaluation of three-dimensional changes in gypsum materials [J].
Luthardt, RG ;
Kühmstedt, P ;
Walter, MH .
DENTAL MATERIALS, 2003, 19 (01) :19-24