Retear Patterns After Arthroscopic Rotator Cuff Repair Single-Row Versus Suture Bridge Technique

被引:211
作者
Cho, Nam Su [1 ]
Yi, Jin Woong [2 ]
Lee, Bong Gun [1 ]
Rhee, Yong Girl [1 ]
机构
[1] Kyung Hee Univ, Sch Med, Dept Orthopaed Surg, Shoulder & Elbow Clin, Seoul 130702, South Korea
[2] Konyang Univ, Sch Med, Dept Orthopaed Surg, Taejon, South Korea
关键词
shoulder; rotator cuff tear; arthroscopic repair; single-row technique; suture bridge technique; retear; INTEGRITY; FAILURE; ANCHORS; SHOULDER; TEARS; FIXATION; REVISION; MODE;
D O I
10.1177/0363546509350081
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A subset of patients is often seen with an unusual pattern of tendon failure after arthroscopic rotator cuff repair using a suture bridge technique. Purpose: To evaluate retear patterns in cases with structural failure after arthroscopic primary repairs of rotator cuff tears. Study Design: Cohort study; Level of evidence, 3. Methods: Forty-six cases revealing retear on magnetic resonance imaging performed at least 6 months after arthroscopic repair for the treatment of full-thickness rotator cuff tear were evaluated. A single-row technique had been performed in 19 cases and a suture bridge in 27 cases. According to retear patterns on postoperative magnetic resonance imaging, cases were divided into type 1 (cuff tissue repaired at the insertion site of rotator cuff was not observed remaining on the greater tuberosity) and type 2 (remnant cuff tissue remained at the insertion site in spite of retear). Results: In the single-row group, 14 cases (73.7%) had type 1 and 5 cases (26.3%) type 2 retear. In the suture bridge group, 7 cases (25.9%) had type 1 and 20 cases (74.1%) type 2. There were statistically significant differences between groups (P = .049). Extent of fatty degeneration of the rotator cuff did not affect retear patterns in the single-row group (P = .160). In the suture bridge group, the percentage of type 1 retear increased with severity of fatty degeneration (P = .030). Extent of muscle atrophy did not affect retear patterns of the single-row group; in the suture bridge group, the percentage of type 1 retear increased with severity of muscle atrophy (P = .904 vs .029). Conclusion: The suture bridge technique tended to better preserve the cuff tissue repaired to the insertion site of the rotator cuff than a single-row technique did; the retear in cases with a suture bridge technique was mainly in the musculotendinous junction. Direct retear at the footprint of the rotator cuff increased with severity of fatty degeneration or muscle atrophy in cases with a suture bridge technique.
引用
收藏
页码:664 / 671
页数:8
相关论文
共 39 条
[1]   Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: Very strong sutures can still slip [J].
Abbi, G ;
Espinoza, L ;
Odell, T ;
Mahar, A ;
Pedowitz, R .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (01) :38-43
[2]   Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures [J].
Barber, F. Alan ;
Coons, David A. ;
Ruiz-Suarez, Michell .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (04) :355-360
[3]   The effect of suture anchor design and orientation on suture abrasion: An in vitro study [J].
Bardana, DD ;
Burks, RT ;
West, JR ;
Greis, PE .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (03) :274-281
[4]  
BELL RH, 2004, SHOULDER, P35
[6]   Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective study [J].
Bishop, Julie ;
Klepps, Steven ;
Lo, Ian K. ;
Bird, Justin ;
Gladstone, James N. ;
Flatow, Evan L. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (03) :290-299
[7]   Complications after arthroscopic rotator cuff repair [J].
Brislin, Kenneth J. ;
Field, Larry D. ;
Savoie, Felix H., III .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (02) :124-128
[8]   Loop security as a determinant of tissue fixation security [J].
Burkhart, SS ;
Wirth, MA ;
Simonick, M ;
Salem, D ;
Lanctot, D ;
Athanasiou, K .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (07) :773-776
[9]   Failure mode of suture anchors as a function of insertion depth [J].
Bynum, CK ;
Lee, S ;
Mahar, A ;
Tasto, J ;
Pedowitz, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (07) :1030-1034
[10]   Arthroscopic rotator cuff repairs: An anatomic and biomechanical rationale for different suture-anchor repair configurations [J].
Cole, Brian J. ;
ElAttrache, Neal S. ;
Anbari, Ammar .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (06) :662-669