A numerical study on the effects of naturally ventilated shaft and fire locations in urban tunnels

被引:18
|
作者
Fan, Chuangang [1 ]
Chen, Jian [1 ]
Mao, Zhanli [4 ]
Zhou, Yang [2 ]
Mao, Shaohua [3 ]
机构
[1] Hefei Univ Technol, Sch Automot & Transportat Engn, Hefei 230009, Anhui, Peoples R China
[2] Cent S Univ, Sch Civil Engn, Changsha 410075, Hunan, Peoples R China
[3] China Ship Dev & Design Ctr, Wuhan 430064, Hubei, Peoples R China
[4] China Peoples Police Univ, Dept Fire Protect Engn, Langfang 065000, Peoples R China
基金
中国国家自然科学基金;
关键词
fire location; natural ventilation; plug-holing; shaft location; urban tunnel; BACK-LAYERING LENGTH; ROAD TUNNEL; TEMPERATURE DISTRIBUTION; SMOKE CONTROL; TRANSVERSE VENTILATION; PERFORMANCE EVALUATION; SPREAD CHARACTERISTICS; VERTICAL SHAFT; FLAME SPREAD; ASPECT RATIO;
D O I
10.1002/fam.2756
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In more and more tunnels, natural ventilation mode with vertical shafts has been gradually employed. However, there are few studies investigating the influences of fire and shaft positions on natural ventilation performance currently. Therefore, this study investigated the effects of the transverse distance from fire source to tunnel sidewall, the longitudinal distance from fire source to shaft, and the transverse distance from shaft to sidewall on natural ventilation effectiveness in a tunnel fire by using Fire Dynamics Simulator. The typical characteristic parameters of smoke, such as mass flow rate, temperature distribution, and velocity vector were analyzed; besides, the phenomenon of plug-holing was discussed. The results have shown that the mass flow rate of gas exhausted by the shaft decreases slightly with the increase of longitudinal distance from fire source to shaft. When the longitudinal distance from fire source to shaft is constant, changing the transverse distance from shaft to sidewall will have a more obvious effect on the effectiveness of exhausting smoke than changing the transverse distance from fire source to sidewall; in addition, the phenomenon of plug-holing is more serious when the shaft is close to the sidewall.
引用
收藏
页码:949 / 960
页数:12
相关论文
共 50 条
  • [1] Numerical study on smoke temperature distribution in naturally ventilated inclined tunnels: Effects of tunnel width and tunnel slope
    Cong, Wei
    Nie, Shibin
    Li, Xin
    Peng, Wei
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 62
  • [2] Smoke distribution in naturally ventilated urban transportation tunnels with multiple shafts
    Tong, Yan
    Shi, Mingheng
    Zhai, Zhiqiang
    Journal of Southeast University (English Edition), 2013, 29 (03) : 305 - 309
  • [3] Effects of elevated pool fire in a naturally ventilated compartment
    Mahesh Kumar Tiwari
    Akhilesh Gupta
    Ravi Kumar
    Pavan Kumar Sharma
    Journal of Thermal Analysis and Calorimetry, 2021, 146 : 341 - 353
  • [4] Theoretical and numerical study on the heat extraction of shafts in a naturally ventilated urban highway tunnel fire under ambient wind environment
    Wu, Peng
    Huang, Qianqian
    Zhou, Ru
    Hao, Min
    Jiang, Juncheng
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 164
  • [5] Effects of elevated pool fire in a naturally ventilated compartment
    Tiwari, Mahesh Kumar
    Gupta, Akhilesh
    Kumar, Ravi
    Sharma, Pavan Kumar
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 146 (01) : 341 - 353
  • [6] Numerical study of natural ventilation in urban shallow tunnels: Impact of shaft cross section
    Xie, Baochao
    Han, Yaxiong
    Huang, He
    Chen, Linna
    Zhou, Yang
    Fan, Chuangang
    Liu, Xiaoping
    SUSTAINABLE CITIES AND SOCIETY, 2018, 42 : 521 - 537
  • [7] Numerical Study on Fire characteristics in Force-Ventilated Compartment with different air inlet locations
    Zhang, Jiaqing
    Zhang, Bosi
    Ji, Kun
    Yan, Bo
    Fan, Minghao
    Li, Wei
    Li, Qiang
    INTERNATIONAL CONFERENCE ON FLUID MECHANICS AND INDUSTRIAL APPLICATIONS (FMIA 2017), 2017, 916
  • [8] Numerical study on the smoke extraction efficiency and the improvement through a smoke reservoir in the naturally ventilated tunnel with vertical shaft
    Xu, Zhisheng
    Xu, Weikun
    He, Lu
    Xie, En
    Wang, Tianxiong
    Tao, Haowen
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 103
  • [9] Numerical study of forced ventilated fire in enclosure
    Liu, YL
    Moser, A
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 243 - 250
  • [10] Numerical study of a naturally cross-ventilated building
    Nikas, K. -S.
    Nikolopoulos, N.
    Nikolopoulos, A.
    ENERGY AND BUILDINGS, 2010, 42 (04) : 422 - 434