X-ray microscopy and automatic detection of defects in through silicon vias in three-dimensional integrated circuits

被引:9
|
作者
Wolz, Benedikt Christopher [1 ,2 ]
Jaremenko, Christian [1 ,2 ,3 ]
Vollnhals, Florian [1 ,2 ]
Kling, Lasse [1 ,2 ]
Wrege, Jan [4 ]
Christiansen, Silke [1 ,2 ,3 ]
机构
[1] Inst Nanotechnol, Forchheim, Germany
[2] Correlat Microscopy gGmbH, Forchheim, Germany
[3] Fraunhofer IKTS, Aussere Nurnberger Str 62, D-91301 Forchheim, Germany
[4] Siemens Healthineers, Forchheim, Germany
基金
欧洲研究理事会;
关键词
3D IC; deep learning; object detection; through silicon vias; x-ray microscopy; THROUGH-SILICON; STRESS; FABRICATION; RELIABILITY; IMPACT;
D O I
10.1002/eng2.12520
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Through silicon vias (TSVs) are a key enabling technology for interconnection and realization of complex three-dimensional integrated circuit (3D-IC) components. In order to perform failure analysis without the need of destructive sample preparation, x-ray microscopy (XRM) is a rising method of analyzing the internal structure of samples. However, there is still a lack of evaluated scan recipes or best practices regarding XRM parameter settings for the study of TSVs in the current state of literature. There is also an increased interest in automated machine learning and deep learning approaches for qualitative and quantitative inspection processes in recent years. Especially deep learning based object detection is a well-known methodology for fast detection and classification capable of working with large volumetric XRM datasets. Therefore, a combined XRM and deep learning object detection workflow for automatic micrometer accurate defect location on liner-TSVs was developed throughout this work. Two measurement setups including detailed information about the used parameters for either full IC device scan or detailed TSV scan were introduced. Both are able to depict delamination defects and finer structures in TSVs with either a low or high resolution. The combination of a 0.4x$$ \times $$ objective with a beam voltage of 40 kV proved to be a good combination for achieving optimal imaging contrast for the full-device scan. However, detailed TSV scans have demonstrated that the use of a 20x$$ \times $$ objective along with a beam voltage of 140 kV significantly improves image quality. A database with 30,000 objects was created for automated data analysis, so that a well-established object recognition method for automated defect analysis could be integrated into the process analysis. This RetinaNet-based object detection method achieves a very strong average precision of 0.94. It supports the detection of erroneous TSVs in both top view and side view, so that defects can be detected at different depths. Consequently, the proposed workflow can be used for failure analysis, quality control or process optimization in R&D environments.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] A thermal model for top layer of three-dimensional integrated circuits with through silicon via
    Wang, F. (cicy4@hotmail.com), 1600, Editorial Board of Chinese Journal of Computational (29):
  • [42] Three-Dimensional Structure and Defects in Colloidal Photonic Crystals Revealed by Tomographic Scanning Transmission X-ray Microscopy
    Hilhorst, Jan
    van Schooneveld, Matti M.
    Wang, Jian
    de Smit, Emiel
    Tyliszczak, Tolek
    Raabe, Joerg
    Hitchcock, Adam P.
    Obst, Martin
    de Groot, Frank M. F.
    Petukhov, Andrei V.
    LANGMUIR, 2012, 28 (07) : 3614 - 3620
  • [43] Fusion of three-dimensional X-ray angiography and three-dimensional echocardiography
    Rasche, Volker
    Mansour, Moussa
    Reddy, Vivek
    Singh, Jagmeet P.
    Qureshi, Answer
    Manzke, Robert
    Sokka, Sham
    Ruskin, Jeremy
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 2 (05) : 293 - 303
  • [44] Fusion of three-dimensional X-ray angiography and three-dimensional echocardiography
    Volker Rasche
    Moussa Mansour
    Vivek Reddy
    Jagmeet P. Singh
    Answer Qureshi
    Robert Manzke
    Sham Sokka
    Jeremy Ruskin
    International Journal of Computer Assisted Radiology and Surgery, 2008, 2 : 293 - 303
  • [45] Study of Bonded Wafers by Using a Synchrotron Radiation Transmission X-ray Microscopy for Three-Dimensional Integrated Circuit
    Kim, Youn-Jang
    Lim, Jae-Hong
    Choi, Kyeong-Keun
    JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2020, 15 (07) : 904 - 908
  • [46] Nondestructive three-dimensional characterization of grain boundaries by X-ray crystal microscopy
    Liu, WJ
    Ice, GE
    Larson, BC
    Yang, WG
    Tischler, JZ
    ULTRAMICROSCOPY, 2005, 103 (03) : 199 - 204
  • [47] Transmission X-ray microscopy-based three-dimensional XANES imaging
    Gao, Ruoyang
    Zhang, Ling
    Tao, Fen
    Wang, Jun
    Du, Guohao
    Xiao, Tiqiao
    Deng, Biao
    ANALYST, 2024, 149 (17) : 4506 - 4513
  • [48] Orientation mapping of steel by scanning three-dimensional x-ray diffraction microscopy
    Hayashi, Yujiro
    Seno, Yoshiki
    Yoshida, Tomoyuki
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2017, 73 : C854 - C854
  • [49] Novel Near Field Detector for Three-Dimensional X-Ray Diffraction Microscopy
    Annett, Scott
    Morelhao, Sergio
    Dale, Darren
    Kycia, Stefan
    MRS ADVANCES, 2018, 3 (39): : 2341 - 2346
  • [50] Application of Three-Dimensional X-Ray Microscopy in Failure Analysis for Sealed Relay
    Lin, Daotan
    2018 19TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY (ICEPT), 2018, : 1351 - 1354