Characterization of platinum nanoparticle-embedded carbon film electrode and its detection of hydrogen peroxide

被引:293
作者
You, TY
Niwa, O
Tomita, M
Hirono, S
机构
[1] NTT Microsyst Integrat Labs, Atsugi, Kanagawa 2430198, Japan
[2] NTT Afty Corp, Tokyo 1810013, Japan
关键词
D O I
10.1021/ac026337w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the highly sensitive determination of acetylcholine (ACh) and choline (Ch) that employs a graphite-like carbon film electrode containing 6.5% platinum (Pt) nanoparticles was developed for use as a detector in microbore liquid chromatography (LC) with a postcolumn enzyme reactor. The film electrode was prepared by RF cosputtering carbon and Pt, which requires only a one-step formation process. This method can control the Pt content of the film at a relatively low deposition temperature (below 200 degreesC). The average size of the Pt nanoparticles was 2.5 run. The film electrode showed excellent electrocatalytic activity, high sensitivity, and negligible baseline drift when detecting hydrogen peroxide. The electrode was modified with glucose oxidase and responded rapidly to glucose with a much more stable baseline current than at a Pt bulk electrode based sensor. Therefore, it is appropriate to employ the electrode to detect trace amounts of biomolecules, such as neurotransmitters and hormones combined with various oxidase enzymes. We used the electrode as a detector for microbore LC and observed a low detection limit of 2.5 and 2.3 fmol (10-muL injection) for ACh and Ch, respectively, which is similar to1 order of magnitude lower than that of a Pt bulk electrode.
引用
收藏
页码:2080 / 2085
页数:6
相关论文
共 47 条
  • [41] Determination of acetylcholine by on-line microdialysis coupled with pre- and post-microbore column enzyme reactors with electrochemical detection
    Tsai, TR
    Cham, TM
    Chen, KC
    Chen, CF
    Tsai, TH
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02): : 151 - 155
  • [42] WANG J, 1999, ELECTROCHEM SOC P, V9932, P428
  • [43] Westbroek P, 1996, FRESEN J ANAL CHEM, V354, P405
  • [44] APPLICATIONS OF WIRED PEROXIDASE ELECTRODES FOR PEROXIDE DETERMINATION IN LIQUID-CHROMATOGRAPHY COUPLED TO OXIDASE IMMOBILIZED ENZYME REACTORS
    YANG, L
    JANLE, E
    HUANG, TH
    GITZEN, J
    KISSINGER, PT
    VREEKE, M
    HELLER, A
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (08) : 1326 - 1331
  • [45] Co-sputtered thin film consisting of platinum nanoparticles embedded in graphite-like carbon and its high electrocatalytic properties for electroanalysis
    You, T
    Niwa, O
    Horiuchi, T
    Tomita, M
    Iwasaki, Y
    Ueno, Y
    Hirono, S
    [J]. CHEMISTRY OF MATERIALS, 2002, 14 (11) : 4796 - 4799
  • [46] Development of a quantitative relationship between inhibition percentage and both incubation time and inhibitor concentration for inhibition biosensors - theoretical and practical considerations
    Zhang, S
    Zhao, H
    John, R
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) : 1119 - 1126
  • [47] Electrochemical preparation of platinum nanocrystallites with size selectivity on basal plane oriented graphite surfaces
    Zoval, JV
    Lee, J
    Gorer, S
    Penner, RM
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (07) : 1166 - 1175