Characterization of platinum nanoparticle-embedded carbon film electrode and its detection of hydrogen peroxide

被引:293
作者
You, TY
Niwa, O
Tomita, M
Hirono, S
机构
[1] NTT Microsyst Integrat Labs, Atsugi, Kanagawa 2430198, Japan
[2] NTT Afty Corp, Tokyo 1810013, Japan
关键词
D O I
10.1021/ac026337w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the highly sensitive determination of acetylcholine (ACh) and choline (Ch) that employs a graphite-like carbon film electrode containing 6.5% platinum (Pt) nanoparticles was developed for use as a detector in microbore liquid chromatography (LC) with a postcolumn enzyme reactor. The film electrode was prepared by RF cosputtering carbon and Pt, which requires only a one-step formation process. This method can control the Pt content of the film at a relatively low deposition temperature (below 200 degreesC). The average size of the Pt nanoparticles was 2.5 run. The film electrode showed excellent electrocatalytic activity, high sensitivity, and negligible baseline drift when detecting hydrogen peroxide. The electrode was modified with glucose oxidase and responded rapidly to glucose with a much more stable baseline current than at a Pt bulk electrode based sensor. Therefore, it is appropriate to employ the electrode to detect trace amounts of biomolecules, such as neurotransmitters and hormones combined with various oxidase enzymes. We used the electrode as a detector for microbore LC and observed a low detection limit of 2.5 and 2.3 fmol (10-muL injection) for ACh and Ch, respectively, which is similar to1 order of magnitude lower than that of a Pt bulk electrode.
引用
收藏
页码:2080 / 2085
页数:6
相关论文
共 47 条
  • [1] ELECTRODEPOSITION OF METAL ADLAYERS ON BORON-DOPED DIAMOND THIN-FILM ELECTRODES
    AWADA, M
    STROJEK, JW
    SWAIN, GM
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (03) : L42 - L45
  • [2] DOPED GLASSY-CARBON MATERIALS (DGC) - LOW-TEMPERATURE SYNTHESIS, STRUCTURE, AND CATALYTIC BEHAVIOR
    CALLSTROM, MR
    NEENAN, TX
    MCCREERY, RL
    ALSMEYER, DC
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (12) : 4954 - 4956
  • [3] Amperometric micro-biosensor array for choline and acetylcholine based on a glassy carbon electrode modified by platinum-black particles and a co-crosslinked enzyme system
    Chen, J
    Lin, XQ
    Chen, ZH
    Wu, SG
    Wang, SQ
    [J]. ANALYTICAL LETTERS, 2001, 34 (04) : 491 - 501
  • [4] Pharmacological evidence for the selectivity of in vivo signals obtained with enzyme-based electrochemical sensors
    Cui, J
    Kulagina, NV
    Michael, AC
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2001, 104 (02) : 183 - 189
  • [5] A SIMPLE, SENSITIVE, AND ECONOMIC ASSAY FOR CHOLINE AND ACETYLCHOLINE USING HPLC, AND ENZYME REACTOR, AND AN ELECTROCHEMICAL DETECTOR
    DAMSMA, G
    WESTERINK, BHC
    HORN, AS
    [J]. JOURNAL OF NEUROCHEMISTRY, 1985, 45 (05) : 1649 - 1652
  • [6] CORE LEVEL PHOTOEMISSION FROM MONOSIZE MASS SELECTED PT CLUSTERS DEPOSITED ON SIO2 AND AMORPHOUS-CARBON
    EBERHARDT, W
    FAYET, P
    COX, D
    FU, Z
    KALDOR, A
    SHERWOOD, R
    SONDERICKER, D
    [J]. PHYSICA SCRIPTA, 1990, 41 (06): : 892 - 895
  • [7] Enea O, 2002, NANO LETT, V2, P241, DOI [10.1021/nl015666l, 10.1021/n10156661]
  • [8] Detection of hydrogen peroxide at mesoporous platinum microelectrodes
    Evans, SAG
    Elliott, JM
    Andrews, LM
    Bartlett, PN
    Doyle, PJ
    Denuault, G
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (06) : 1322 - 1326
  • [9] Mediatorless biosensor for H2O2 based on recombinant forms of horseradish peroxidase directly adsorbed on polycrystalline gold
    Ferapontova, EE
    Grigorenko, VG
    Egorov, AM
    Börchers, T
    Ruzgas, T
    Gorton, L
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) : 147 - 157
  • [10] AN ENZYME-REACTOR FOR ELECTROCHEMICAL MONITORING OF CHOLINE AND ACETYLCHOLINE - APPLICATIONS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, BRAIN-TISSUE, MICRODIALYSIS AND CEREBROSPINAL-FLUID
    FLENTGE, F
    VENEMA, K
    KOCH, T
    KORF, J
    [J]. ANALYTICAL BIOCHEMISTRY, 1992, 204 (02) : 305 - 310