ELECTROMYOGRAPHICAL AND PERCEPTUAL RESPONSES TO DIFFERENT RESISTANCE INTENSITIES IN A SQUAT PROTOCOL: DOES PERFORMING SETS TO FAILURE WITH LIGHT LOADS PRODUCE THE SAME ACTIVITY?

被引:36
作者
Looney, David P. [1 ]
Kraemer, William J. [2 ]
Joseph, Michael F. [1 ]
Comstock, Brett A. [1 ]
Denegar, Craig R. [1 ]
Flanagan, Shawn D. [2 ]
Newton, Robert U. [3 ]
Szivak, Tunde K. [2 ]
DuPont, William H. [2 ]
Hooper, David R. [2 ]
Hakkinen, Keijo [4 ]
Maresh, Carl M. [2 ]
机构
[1] Univ Connecticut, Coll Agr Hlth & Nat Resources, Dept Kinesiol, Storrs, CT USA
[2] Ohio State Univ, Dept Human Sci, Columbus, OH 43210 USA
[3] Edith Cowan Univ, Sch Biomed & Sports Sci, Joondalup, Australia
[4] Univ Jyvaskyla, Dept Biol Phys Act, SF-40100 Jyvaskyla, Finland
关键词
weight training; high intensity; single set; drop sets; ratings of perceived exertion; VASTUS LATERALIS MUSCLE; MOTOR UNIT BEHAVIOR; SURFACE EMG; RECRUITMENT THRESHOLD; DYNAMIC CONTRACTIONS; FIRING RATES; EXERCISE; FATIGUE; AMPLITUDE; STRENGTH;
D O I
10.1519/JSC.0000000000001109
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Looney, DP, Kraemer, WJ, Joseph, MF, Comstock, BA, Denegar, CR, Flanagan, SD, Newton, RU, Szivak, TK, DuPont, WH, Hooper, DR, Hakkinen, K, and Maresh, CM. Electromyographical and perceptual responses to different resistance intensities in a squat protocol: does performing sets to failure with light loads produce the same activity? J Strength Cond Res 30(3): 792-799, 2016This investigation examined peak motor unit activity during sets that differed in resistance (50, 70, or 90% 1 repetition maximum [1RM]). Ten resistance-trained men (age, 23 +/- 3 years; height, 187 +/- 7 cm; body mass, 91.5 +/- 6.9 kg; squat 1RM, 141 +/- 28 kg) were assessed by electromyography (EMG) on the vastus lateralis and vastus medialis muscles in a randomized within-subject experiment consisting of 2 test visits: a drop-set day and a single-set day using only the 50% of 1RM intensity performed to failure. At the start of each day, subjects performed 2 submaximal repetition sets (50% 1RM x 10 repetitions and 70% 1RM x 7 repetitions). On the drop-set day, subjects performed 3 consecutive maximal repetition sets at 90%, 70%, and 50% 1RM to failure with no rest periods in between. On the single-set day, subjects performed a maximal repetition set at 50% 1RM to failure. Overall, the maximal repetition sets to failure at 50% and 70% 1RM resulted in higher peak EMG amplitude than during submaximal repetition sets with the same resistance. However, peak EMG amplitude was significantly (p 0.05) greater in the maximal 90% 1RM set than all other sets performed. When sets were performed to failure, ratings of perceived exertion (CR-10) did not differ over the intensity range of loads and suggests that perception is not capable of accurately detecting the actual amount of motor unit activation. The results of this investigation indicate that using higher external resistance is a more effective means of increasing motor unit activity than increasing the number of repetitions performed with lighter weights even when the end point is muscular failure. Accordingly, previous recommendations for the use of heavier loads during resistance training programs to stimulate the maximal development of strength and hypertrophy are further supported.
引用
收藏
页码:792 / 799
页数:8
相关论文
共 42 条
[1]   Firing rates of motor units in human vastus lateralis muscle during fatiguing isometric contractions [J].
Adam, A ;
De Luca, CJ .
JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (01) :268-280
[2]   Recruitment order of motor units in human vastus lateralis muscle is maintained during fatiguing contractions [J].
Adam, A ;
De Luca, CJ .
JOURNAL OF NEUROPHYSIOLOGY, 2003, 90 (05) :2919-2927
[3]   Short vs. long rest period between the sets in hypertrophic resistance training:: Influence on muscle strength, size, and hormonal adaptations in trained men [J].
Ahtiainen, JP ;
Pakarinen, A ;
Alen, M ;
Kraemer, WJ ;
Häkkinen, K .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2005, 19 (03) :572-582
[4]  
Ahtlainen JP, 2003, INT J SPORTS MED, V24, P410
[6]   Motor unit behaviour and contractile changes during fatigue in the human first dorsal interosseus [J].
Carpentier, A ;
Duchateau, J ;
Hainaut, K .
JOURNAL OF PHYSIOLOGY-LONDON, 2001, 534 (03) :903-912
[7]   MOTOR UNIT RECRUITMENT AND THE GRADATION OF MUSCLE FORCE [J].
CLAMANN, HP .
PHYSICAL THERAPY, 1993, 73 (12) :830-843
[8]   Electromyography in sports and occupational settings: an update of its limits and possibilities [J].
Clarys, JP .
ERGONOMICS, 2000, 43 (10) :1750-1762
[9]   Reliability of EMG measurements for trunk muscles during maximal and sub-maximal voluntary isometric contractions in healthy controls and CLBP patients [J].
Dankaerts, W ;
O'Sullivan, PB ;
Burnett, AF ;
Straker, LM ;
Danneels, LA .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2004, 14 (03) :333-342
[10]   Hierarchical control of motor units in voluntary contractions [J].
De Luca, Carlo J. ;
Contessa, Paola .
JOURNAL OF NEUROPHYSIOLOGY, 2012, 107 (01) :178-195