High-speed X-ray video demonstrates significant skin movement errors with standard optical kinematics during rat locomotion

被引:69
作者
Bauman, Jay M. [1 ]
Chang, Young-Hui [1 ]
机构
[1] Georgia Inst Technol, Comparat Neuromech Lab, Sch Appl Physiol, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
Rodent; Walking; Biomechanics; Assay; Joint angle; Gait analysis; PERIPHERAL-NERVE INJURY; IN-VIVO MEASUREMENT; CINERADIOGRAPHIC ANALYSIS; TREADMILL LOCOMOTION; HINDLIMB KINEMATICS; JOINT KINEMATICS; KNEE KINEMATICS; LIMB KINEMATICS; SCIATIC-NERVE; RECOVERY;
D O I
10.1016/j.jneumeth.2009.10.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The sophistication of current rodent injury and disease models outpaces that of the most commonly used behavioral assays. The first objective of this study was to measure rat locomotion using high-speed X-ray video to establish an accurate baseline for rat hindlimb kinematics. The second objective was to quantify the kinematics errors due to skin movement artefacts by simultaneously recording and comparing hindlimb kinematics derived from skin markers and from direct visualization of skeletal landmarks. Joint angle calculations from skin-derived kinematics yielded errors as high as 39 degrees in the knee and 31 degrees in the hip around paw contact with respect to the X-ray data. Triangulation of knee position from the ankle and hip skin markers provided closer, albeit still inaccurate, approximations of bone-derived, X-ray kinematics. We found that soft tissue movement errors are the result of multiple factors, the most impressive of which is overall limb posture. Treadmill speed had surprisingly little effect on kinematics errors. These findings illustrate the significance and context of skin movement error in rodent kinematics. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 45 条
[1]   Correcting for deformation in skin-based marker systems [J].
Alexander, EJ ;
Andriacchi, TP .
JOURNAL OF BIOMECHANICS, 2001, 34 (03) :355-361
[2]   FUNCTIONAL-EVALUATION OF COMPLETE SCIATIC, PERONEAL, AND POSTERIOR TIBIAL NERVE LESIONS IN THE RAT [J].
BAIN, JR ;
MACKINNON, SE ;
HUNTER, DA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 83 (01) :129-136
[3]   Adaptations in the walking pattern of spinal cord injured rats [J].
Ballermann, Mark ;
Tse, Arthur D. Y. ;
Misiaszek, John E. ;
Fouad, Karim .
JOURNAL OF NEUROTRAUMA, 2006, 23 (06) :897-907
[4]   Comparing in vivo kinematics of unicondylar and bi-unicondylar knee replacements [J].
Banks, SA ;
Fregly, BJ ;
Boniforti, F ;
Reinschmidt, C ;
Romagnoli, S .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (07) :551-556
[5]   A SENSITIVE AND RELIABLE LOCOMOTOR RATING-SCALE FOR OPEN-FIELD TESTING IN RATS [J].
BASSO, DM ;
BEATTIE, MS ;
BRESNAHAN, JC .
JOURNAL OF NEUROTRAUMA, 1995, 12 (01) :1-21
[6]   X-ray kinematic analysis of shoulder movements during target reaching and food taking in the cat [J].
Boczek-Funcke, A ;
Kuhtz-Buschbeck, JP ;
Illert, M .
EUROPEAN JOURNAL OF NEUROSCIENCE, 1999, 11 (03) :986-996
[7]   X-ray kinematic analysis of forelimb movements during target reaching and food taking in the cat [J].
Boczek-Funcke, A ;
Kuhtz-Buschbeck, JP ;
Paschmeyer, B ;
Illert, M .
EUROPEAN JOURNAL OF NEUROSCIENCE, 2000, 12 (05) :1817-1826
[8]   X-RAY KINEMATOGRAPHY AS A TOOL FOR INVESTIGATIONS OF DISTAL LIMB MOVEMENTS OF THE CAT [J].
BOCZEKFUNCKE, A ;
ILLERT, M ;
NATH, D ;
WIESE, H .
JOURNAL OF NEUROSCIENCE METHODS, 1994, 52 (01) :11-16
[9]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100
[10]  
CHANG YH, 2008, P N AM C BIOM