Computational stress-deformation analysis of arterial walls including high-pressure response

被引:79
作者
Holzapfel, Gerhard A.
Gasser, Thomas C.
机构
[1] Royal Inst Technol, Dept Solid Mech, Sch Engn Sci, S-10044 Stockholm, Sweden
[2] Graz Univ Technol, A-8010 Graz, Austria
关键词
angioplasty; arterial wall mechanics; arteries; high-pressure response; soft tissue;
D O I
10.1016/j.ijcard.2006.03.033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Changes in the mechanical behavior of arteries after balloon angioplasty cause cell reactions that may be responsible for restenosis. Hence, the study of the stress-deforination changes in arterial walls following supraphysiological tissue loading is an essential task. Methods: A normal LAD coronary artery was modeled and computationally analyzed as a two-layer, thick-walled, anisotropic and inelastic circular tube including residual strains. Each layer was treated as a fibre-matrix composite. The tube was subjected to an axial stretch of 1. 1 and a transmural pressure of 750 min Hg. Since overstretch of rerrmant non-diseased tissue in lesions is a primary mechanism of lumen enlargement this model approach represents a reasonable first step. Results: At physiological loading, the residual stresses led to a significant reduction of the high circumferential stress values at the inner wall, and the stress gradients. At low pressure level the media was the mechanically relevant layer, while at supraphysiological loading, the adventitia was the predominant load-carrying constituent providing a stiff support for 'redistribution' of soft plaque components by means of radial compression. After unloading to physiological loading conditions the stress state in the arterial wall differed significantly from that before inflation; the stress gradient in the media even changed its sign. Complete unloading indicated lumen enlargement, material softening and energy dissipation, which is in agreement with experimental studies. Conclusions: This method may be useful to improve interventional protocols for reducing the dilatational trauma, and thereby the adverse biological reaction in arterial walls following balloon angioplasty. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 39 条
[1]  
Abe H, 1996, DATA BOOK MECH PROPE
[2]  
[Anonymous], 1985, IMPROVEMENT MYOCARDI
[3]  
[Anonymous], BIOMECHANICS SOFT TI
[4]  
[Anonymous], 2013, Biomechanics: Motion, Flow, Stress, and Growth
[5]  
[Anonymous], ASME 1991 BIOM S AMD
[6]  
[Anonymous], 2005, HEART DIS STROKE STA
[7]   3-D reconstruction of tissue components for atherosclerotic human arteries using ex vivo high-resolution MRI [J].
Auer, M ;
Stollberger, R ;
Regitnig, P ;
Ebner, F ;
Holzapfel, GA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (03) :345-357
[8]   MEASUREMENTS FROM LIGHT AND POLARIZED-LIGHT MICROSCOPY OF HUMAN CORONARY-ARTERIES FIXED AT DISTENDING PRESSURE [J].
CANHAM, PB ;
FINLAY, HM ;
DIXON, JG ;
BOUGHNER, DR ;
CHEN, A .
CARDIOVASCULAR RESEARCH, 1989, 23 (11) :973-982
[9]   A PIECE-WISE NONLINEAR ELASTIC STRESS EXPRESSION OF HUMAN AND PIG CORONARY-ARTERIES TESTED INVITRO [J].
CARMINES, DV ;
MCELHANEY, JH ;
STACK, R .
JOURNAL OF BIOMECHANICS, 1991, 24 (10) :899-906
[10]   THE MECHANISM OF BALLOON ANGIOPLASTY [J].
CASTANEDAZUNIGA, WR ;
FORMANEK, A ;
TADAVARTHY, M ;
VLODAVER, Z ;
EDWARDS, JE ;
ZOLLIKOFER, C ;
AMPLATZ, K .
RADIOLOGY, 1980, 135 (03) :565-571